Driven equilibrium (drive) MR imaging of the cranial nerves V-VIII: comparison with the T2-weighted 3D TSE sequence

被引:39
作者
Ciftci, E [1 ]
Anik, Y [1 ]
Arslan, A [1 ]
Akansel, G [1 ]
Sarisoy, T [1 ]
Demirci, A [1 ]
机构
[1] Kocaeli Univ, Sch Radiol, TR-41100 Kocaeli, Turkey
关键词
magnetic resonance imaging; 3D turbo spin echo sequence; trigerninat nerve; abducens nerve; facial nerve; vestibulocochlear nerve;
D O I
10.1016/j.ejrad.2003.10.019
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study is to evaluate the efficacy of the driven equilibrium radio frequency reset pulse (DRIVE) on image quality and nerve detection when used in adjunction with T2-weighted 3D turbo spin-echo (TSE) sequence. Materials and methods: Forty-five patients with cranial nerve symptoms referable to the cerebellopontine angle (CPA) were examined using a T2-weighted 3D TSE pulse sequence with and without DRIVE. MR imaging was performed on a 1.5-T MRI scanner. In addition to the axial resource images, reformatted oblique sagittal, oblique coronal and maximum intensity projection (MIP) images of the inner ear were evaluated. The nerve identification and image quality were graded for the cranial nerves V-VIII as well as inner ear structures. These structures were chosen because fluid-solid interfaces existed due to the CSF around (the cranial nerves V-VIII) or the endolymph within (the inner ear structures). Statistical analysis was performed using the Wilcoxon test. P < 0.05 was considered significant. Results: The addition of the DRIVE pulse shortens the scan time by 25%. T2-weighted 3D TSE sequence with DRIVE performed slightly better than the T2-weighted 3D TSE sequence without DRIVE(.)in identifying the individual nerves. The image quality was also slightly better with DRIVE. Conclusion: The addition of the DRIVE pulse to the T2-weighted 3D TSE sequence is preferable when imaging the cranial nerves surrounded by the CSF, or fluid-filled structures because of shorter scan time and better image quality due to reduced flow artifacts. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:234 / 240
页数:7
相关论文
共 45 条
[31]   Visual assessment of cerebrospinal fluid flow dynamics using 3D T2-weighted SPACE sequence-based classification system [J].
Naldemir, Ibrahim Feyyaz ;
Karaman, Ahmet Kursat ;
Ogul, Hayri ;
Onbas, Omer .
ACTA RADIOLOGICA, 2024, 65 (12) :1576-1582
[32]   Comprehensive Volumetric Analysis of Mecp2-Null Mouse Model for Rett Syndrome by T2-Weighted 3D Magnetic Resonance Imaging [J].
Akaba, Yuichi ;
Shiohama, Tadashi ;
Komaki, Yuji ;
Seki, Fumiko ;
Ortug, Alpen ;
Sawada, Daisuke ;
Uchida, Wataru ;
Kamagata, Koji ;
Shimoji, Keigo ;
Aoki, Shigeki ;
Takahashi, Satoru ;
Suzuki, Takeshi ;
Natsume, Jun ;
Takahashi, Emi ;
Tsujimura, Keita .
FRONTIERS IN NEUROSCIENCE, 2022, 16
[33]   3D T2-Weighted Sampling Perfection with Application-Optimized Contrasts Using Different Flip Angle Evolutions (SPACE) and 3D Time-of-Flight (TOF) MR Angiography Fusion Imaging for Occluded Intracranial Arteries [J].
Ozaki, Saya ;
Okamoto, Shigetaka ;
Shinohara, Naoki .
JOURNAL OF NEUROENDOVASCULAR THERAPY, 2022, 16 (09) :452-457
[34]   Combined model-based and deep learning-based automated 3D zonal segmentation of the prostate on T2-weighted MR images: clinical evaluation [J].
Olivier Rouvière ;
Paul Cezar Moldovan ;
Anna Vlachomitrou ;
Sylvain Gouttard ;
Benjamin Riche ;
Alexandra Groth ;
Mark Rabotnikov ;
Alain Ruffion ;
Marc Colombel ;
Sébastien Crouzet ;
Juergen Weese ;
Muriel Rabilloud .
European Radiology, 2022, 32 :3248-3259
[35]   Combined model-based and deep learning-based automated 3D zonal segmentation of the prostate on T2-weighted MR images: clinical evaluation [J].
Rouviere, Olivier ;
Moldovan, Paul Cezar ;
Vlachomitrou, Anna ;
Gouttard, Sylvain ;
Riche, Benjamin ;
Groth, Alexandra ;
Rabotnikov, Mark ;
Ruffion, Alain ;
Colombel, Marc ;
Crouzet, Sebastien ;
Weese, Juergen ;
Rabilloud, Muriel .
EUROPEAN RADIOLOGY, 2022, 32 (05) :3248-3259
[36]   Comparison between 2D FSE T2-weighted Dixon MRI and contrast-enhanced 2D FSE and 3D FSPGR T1-weighted Dixon MRI to quantify inflammation in hands of patients with early rheumatoid arthritis [J].
Dion, Brice ;
Lacrosse, Romain ;
Michoux, Nicolas ;
Stoenoiu, Maria ;
Durez, Patrick ;
Lecouvet, Frederic ;
Kirchgesner, Thomas .
DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2023, 104 (7-8) :351-358
[37]   Detection of the glenoid bare spot by non-arthrographic MR imaging, conventional MR arthrography, and 3D high-resolution T1-weighted VIBE MR arthrography: comparison with CT arthrography [J].
Mehmet Ali Ozel ;
Hayri Ogul ;
Ali Koksal ;
Mehmet Kose ;
Kutsi Tuncer ;
Suat Eren ;
Mecit Kantarci .
European Radiology, 2023, 33 :3276-3285
[38]   Detection of the glenoid bare spot by non-arthrographic MR imaging, conventional MR arthrography, and 3D high-resolution T1-weighted VIBE MR arthrography: comparison with CT arthrography [J].
Ozel, Mehmet Ali ;
Ogul, Hayri ;
Koksal, Ali ;
Kose, Mehmet ;
Tuncer, Kutsi ;
Eren, Suat ;
Kantarci, Mecit .
EUROPEAN RADIOLOGY, 2023, 33 (05) :3276-3285
[39]   Perirenal lymphatic systems: Evaluation using spectral presaturation with inversion recovery T2-weighted MR images with 3D volume isotropic turbo spin-echo acquisition at 3.0T [J].
Matsumoto, Shunro ;
Mori, Hiromu ;
Kiyonaga, Maki ;
Yamada, Yasunari ;
Takaji, Ryo ;
Sato, Fuminori ;
Mimata, Hiromitsu ;
Hijiya, Naoki ;
Moriyama, Masatsugu ;
Tanoue, Rika ;
Tomonari, Kenichiro ;
Matsumoto, Tomohiro ;
Hasebe, Terumitsu .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (04) :897-905
[40]   Phase-Sensitive, Dual-Acquisition, Single-Slab, 3D, Turbo-Spin-Echo Pulse Sequence for Simultaneous T2-Weighted and Fluid-Attenuated Whole-Brain Imaging [J].
Park, Jaeseok ;
Park, Suhyung ;
Kim, Eung Yeop ;
Suh, Jin-Suck .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (05) :1422-1430