Driven equilibrium (drive) MR imaging of the cranial nerves V-VIII: comparison with the T2-weighted 3D TSE sequence

被引:39
作者
Ciftci, E [1 ]
Anik, Y [1 ]
Arslan, A [1 ]
Akansel, G [1 ]
Sarisoy, T [1 ]
Demirci, A [1 ]
机构
[1] Kocaeli Univ, Sch Radiol, TR-41100 Kocaeli, Turkey
关键词
magnetic resonance imaging; 3D turbo spin echo sequence; trigerninat nerve; abducens nerve; facial nerve; vestibulocochlear nerve;
D O I
10.1016/j.ejrad.2003.10.019
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study is to evaluate the efficacy of the driven equilibrium radio frequency reset pulse (DRIVE) on image quality and nerve detection when used in adjunction with T2-weighted 3D turbo spin-echo (TSE) sequence. Materials and methods: Forty-five patients with cranial nerve symptoms referable to the cerebellopontine angle (CPA) were examined using a T2-weighted 3D TSE pulse sequence with and without DRIVE. MR imaging was performed on a 1.5-T MRI scanner. In addition to the axial resource images, reformatted oblique sagittal, oblique coronal and maximum intensity projection (MIP) images of the inner ear were evaluated. The nerve identification and image quality were graded for the cranial nerves V-VIII as well as inner ear structures. These structures were chosen because fluid-solid interfaces existed due to the CSF around (the cranial nerves V-VIII) or the endolymph within (the inner ear structures). Statistical analysis was performed using the Wilcoxon test. P < 0.05 was considered significant. Results: The addition of the DRIVE pulse shortens the scan time by 25%. T2-weighted 3D TSE sequence with DRIVE performed slightly better than the T2-weighted 3D TSE sequence without DRIVE(.)in identifying the individual nerves. The image quality was also slightly better with DRIVE. Conclusion: The addition of the DRIVE pulse to the T2-weighted 3D TSE sequence is preferable when imaging the cranial nerves surrounded by the CSF, or fluid-filled structures because of shorter scan time and better image quality due to reduced flow artifacts. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:234 / 240
页数:7
相关论文
共 45 条
[21]   Comparison of 2D Thin Section Dixon, 3D Isotropic SPACE, and 2D T2-Weighted Sequences in Ankle MRI [J].
Ahn, Tae Ran ;
Jeong, Yu Mi ;
Jeon, Ji Young ;
Park, So Hyun ;
Lee, Sheen-Woo .
INVESTIGATIVE MAGNETIC RESONANCE IMAGING, 2022, 26 (04) :284-293
[22]   MR urography (MRU) of non-dilated ureter with diuretic administration: Static fluid 2D FSE T2-weighted versus 3D gadolinium T1-weighted GE excretory MR [J].
Roy, C. ;
Ohana, M. ;
Host, Ph. ;
Alemann, G. ;
Labani, A. ;
Wattiez, A. ;
Lang, H. .
EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2014, 1 :6-13
[23]   3.0 T prostate MRI: Visual assessment of 2D and 3D T2-weighted imaging sequences using PI-QUAL score [J].
Brillat-Savarin, Nina ;
Wu, Carine ;
Aupin, Laurene ;
Thoumin, Camille ;
Hamzaoui, Dimitri ;
Renard-Penna, Raphaele .
EUROPEAN JOURNAL OF RADIOLOGY, 2023, 166
[24]   Comparison between contrast-enhanced fat-suppressed 3D FLAIR brain MR images and T2-weighted orbital MR images at 3 Tesla for the diagnosis of acute optic neuritis [J].
Manasse, Sharmiladevi ;
Koskas, Patricia ;
Savatovsky, Julien ;
Deschamps, Romain ;
Vignal-Clermont, Catherine ;
de la Motte, Marine Boudot ;
Papeix, Caroline ;
Trunet, Stephanie ;
Lecler, Augustin .
DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2024, 105 (12) :481-488
[25]   Comparison of compressed sensing-sensitivity encoding (CS-SENSE) accelerated 3D T2W TSE sequence versus conventional 3D and 2D T2W TSE sequences in rectal cancer: a prospective study [J].
Xiaoling Gong ;
Daguang Wen ;
Hong Wei ;
Yu Shen ;
Yujiao Deng ;
Ya Wang ;
Mingtian Wei ;
Xiaoxiao Zhang ;
Xiaoyong Zhang ;
Ziqiang Wang ;
Bing Wu .
Abdominal Radiology, 2022, 47 :3660-3670
[26]   Comparison of compressed sensing-sensitivity encoding (CS-SENSE) accelerated 3D T2W TSE sequence versus conventional 3D and 2D T2W TSE sequences in rectal cancer: a prospective study [J].
Gong, Xiaoling ;
Wen, Daguang ;
Wei, Hong ;
Shen, Yu ;
Deng, Yujiao ;
Wang, Ya ;
Wei, Mingtian ;
Zhang, Xiaoxiao ;
Zhang, Xiaoyong ;
Wang, Ziqiang ;
Wu, Bing .
ABDOMINAL RADIOLOGY, 2022, 47 (11) :3660-3670
[27]   Assessment of fetal corpus callosum biometry by 3D super-resolution reconstructed T2-weighted magnetic resonance imaging [J].
Lamon, Samuel ;
de Dumast, Priscille ;
Sanchez, Thomas ;
Dunet, Vincent ;
Pomar, Leo ;
Vial, Yvan ;
Koob, Meriam ;
Cuadra, Meritxell Bach .
FRONTIERS IN NEUROLOGY, 2024, 15
[28]   Enhanced urethral identification for radiotherapy planning using fat-suppressed 3D T2-weighted magnetic resonance imaging [J].
Kato, Yutaka ;
Nakaya, Takayoshi ;
Okudaira, Kuniyasu ;
Noguchi, Yumiko ;
Kawamura, Mariko ;
Ishihara, Shunichi ;
Naganawa, Shinji .
RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2025, 18 (02) :589-596
[29]   Comparison of the reproducibility of 2D and 3D amide proton transfer weighted imaging in intracranial rat gliomas at 3 T [J].
Chen, Xin ;
Wei, Xinhua ;
Liu, Lingling ;
Yan, Xu ;
Zhu, Xiaolei ;
Xu, Xiangdong ;
Jiang, Xinqing ;
Liu, Zaiyi .
CHINESE JOURNAL OF ACADEMIC RADIOLOGY, 2020, 3 (01) :59-64
[30]   Comparison of the reproducibility of 2D and 3D amide proton transfer weighted imaging in intracranial rat gliomas at 3 T [J].
Xin Chen ;
Xinhua Wei ;
Lingling Liu ;
Xu Yan ;
Xiaolei Zhu ;
Xiangdong Xu ;
Xinqing Jiang ;
Zaiyi Liu .
Chinese Journal of Academic Radiology, 2020, 3 :59-64