Driven equilibrium (drive) MR imaging of the cranial nerves V-VIII: comparison with the T2-weighted 3D TSE sequence

被引:39
作者
Ciftci, E [1 ]
Anik, Y [1 ]
Arslan, A [1 ]
Akansel, G [1 ]
Sarisoy, T [1 ]
Demirci, A [1 ]
机构
[1] Kocaeli Univ, Sch Radiol, TR-41100 Kocaeli, Turkey
关键词
magnetic resonance imaging; 3D turbo spin echo sequence; trigerninat nerve; abducens nerve; facial nerve; vestibulocochlear nerve;
D O I
10.1016/j.ejrad.2003.10.019
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study is to evaluate the efficacy of the driven equilibrium radio frequency reset pulse (DRIVE) on image quality and nerve detection when used in adjunction with T2-weighted 3D turbo spin-echo (TSE) sequence. Materials and methods: Forty-five patients with cranial nerve symptoms referable to the cerebellopontine angle (CPA) were examined using a T2-weighted 3D TSE pulse sequence with and without DRIVE. MR imaging was performed on a 1.5-T MRI scanner. In addition to the axial resource images, reformatted oblique sagittal, oblique coronal and maximum intensity projection (MIP) images of the inner ear were evaluated. The nerve identification and image quality were graded for the cranial nerves V-VIII as well as inner ear structures. These structures were chosen because fluid-solid interfaces existed due to the CSF around (the cranial nerves V-VIII) or the endolymph within (the inner ear structures). Statistical analysis was performed using the Wilcoxon test. P < 0.05 was considered significant. Results: The addition of the DRIVE pulse shortens the scan time by 25%. T2-weighted 3D TSE sequence with DRIVE performed slightly better than the T2-weighted 3D TSE sequence without DRIVE(.)in identifying the individual nerves. The image quality was also slightly better with DRIVE. Conclusion: The addition of the DRIVE pulse to the T2-weighted 3D TSE sequence is preferable when imaging the cranial nerves surrounded by the CSF, or fluid-filled structures because of shorter scan time and better image quality due to reduced flow artifacts. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:234 / 240
页数:7
相关论文
共 16 条
[1]   MR imaging of the inner ear and cerebellopontine angle: Comparison of three-dimensional and two-dimensional sequences [J].
Czerny, C ;
Rand, T ;
Gstoettner, W ;
Woelfl, G ;
Imhof, H ;
Trattnig, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (03) :791-796
[2]  
GUIRADO CR, 1995, AM J NEURORADIOL, V16, P1909
[3]  
Held P, 2000, J NEURORADIOLOGY, V27, P173
[4]   MRI of inner ear and facial nerve pathology using 3D MP-RAGE and 3D CISS sequences [J].
Held, P ;
Fellner, C ;
Fellner, F ;
Seitz, J ;
Graf, S ;
Hilbert, M ;
Strutz, J .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (834) :558-566
[5]   MRI of inner ear anatomy using 3D MP-RAGE and 3D CISS sequences [J].
Held, P ;
Fellner, C ;
Fellner, F ;
Seitz, J ;
Strutz, J .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (833) :465-472
[6]  
Kim HS, 1998, AM J NEURORADIOL, V19, P1155
[7]   MRI of the inner ear -: Comparison of axial T2-weighted, three-dimensional turbo spin-echo images, maximum-intensity projections, and volume rendering [J].
Krombach, GA ;
Schmitz-Rode, T ;
Tacke, J ;
Glowinski, A ;
Nolte-Ernsting, CC ;
Günther, RW .
INVESTIGATIVE RADIOLOGY, 2000, 35 (06) :337-342
[8]  
Laine FJ, 1998, NEUROIMAG CLIN N AM, V8, P69
[9]   MR imaging of the inner ear: Comparison of a three-dimensional fast spin-echo sequence with use of a dedicated quadrature-surface coil with a gadolinium-enhanced spoiled gradient-recalled sequence [J].
Naganawa, S ;
Ito, T ;
Fukatsu, H ;
Ishigaki, T ;
Nakashima, T ;
Ichinose, N ;
Kassai, Y ;
Miyazaki, M .
RADIOLOGY, 1998, 208 (03) :679-685
[10]  
Naganawa S, 2002, AM J NEURORADIOL, V23, P299