Driven equilibrium (drive) MR imaging of the cranial nerves V-VIII: comparison with the T2-weighted 3D TSE sequence

被引:39
|
作者
Ciftci, E [1 ]
Anik, Y [1 ]
Arslan, A [1 ]
Akansel, G [1 ]
Sarisoy, T [1 ]
Demirci, A [1 ]
机构
[1] Kocaeli Univ, Sch Radiol, TR-41100 Kocaeli, Turkey
关键词
magnetic resonance imaging; 3D turbo spin echo sequence; trigerninat nerve; abducens nerve; facial nerve; vestibulocochlear nerve;
D O I
10.1016/j.ejrad.2003.10.019
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study is to evaluate the efficacy of the driven equilibrium radio frequency reset pulse (DRIVE) on image quality and nerve detection when used in adjunction with T2-weighted 3D turbo spin-echo (TSE) sequence. Materials and methods: Forty-five patients with cranial nerve symptoms referable to the cerebellopontine angle (CPA) were examined using a T2-weighted 3D TSE pulse sequence with and without DRIVE. MR imaging was performed on a 1.5-T MRI scanner. In addition to the axial resource images, reformatted oblique sagittal, oblique coronal and maximum intensity projection (MIP) images of the inner ear were evaluated. The nerve identification and image quality were graded for the cranial nerves V-VIII as well as inner ear structures. These structures were chosen because fluid-solid interfaces existed due to the CSF around (the cranial nerves V-VIII) or the endolymph within (the inner ear structures). Statistical analysis was performed using the Wilcoxon test. P < 0.05 was considered significant. Results: The addition of the DRIVE pulse shortens the scan time by 25%. T2-weighted 3D TSE sequence with DRIVE performed slightly better than the T2-weighted 3D TSE sequence without DRIVE(.)in identifying the individual nerves. The image quality was also slightly better with DRIVE. Conclusion: The addition of the DRIVE pulse to the T2-weighted 3D TSE sequence is preferable when imaging the cranial nerves surrounded by the CSF, or fluid-filled structures because of shorter scan time and better image quality due to reduced flow artifacts. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:234 / 240
页数:7
相关论文
共 43 条
  • [1] Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences
    Murat Ucar
    Nil Tokgoz
    Cagri Damar
    Ayse Gul Alimli
    Fatih Oncu
    Japanese Journal of Radiology, 2015, 33 : 94 - 101
  • [2] Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences
    Ucar, Murat
    Tokgoz, Nil
    Damar, Cagri
    Alimli, Ayse Gul
    Oncu, Fatih
    JAPANESE JOURNAL OF RADIOLOGY, 2015, 33 (02) : 94 - 101
  • [3] A comparison study between 3D T2-weighted SPACE and conventional 2D T2-weighted turbo spin echo in assessment of carotid plaque
    Lv, Peng
    Dai, Yuanyuan
    Lin, Jiang
    Zhang, Weisheng
    Liu, Hao
    Liu, Hui
    Tang, Xiao
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (03) : 395 - 400
  • [4] A comparison study between 3D T2-weighted SPACE and conventional 2D T2-weighted turbo spin echo in assessment of carotid plaque
    Peng Lv
    Yuanyuan Dai
    Jiang Lin
    Weisheng Zhang
    Hao Liu
    Hui Liu
    Xiao Tang
    The International Journal of Cardiovascular Imaging, 2017, 33 : 395 - 400
  • [5] Comparison of FSE T2W and 3D FIESTA sequences in the evaluation of posterior fossa cranial nerves with MR cisternography
    Hatipoglu, Hatice Guel
    Durakoglugil, Tugba
    Ciliz, Deniz
    Yueksel, Enis
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2007, 13 (02): : 56 - 60
  • [6] Comparison of a T2*W. 3D CISS and a T2 W. 3D turbo spin echo sequence for the anatomical study of facial and vestibulocochlear nerves
    Held, P
    Fründ, R
    Seitz, J
    Nitz, W
    Haffke, T
    Hees, H
    Waldeck, A
    JOURNAL OF NEURORADIOLOGY, 2000, 27 (03) : 173 - 178
  • [7] Accelerated 3D T2-weighted images using compressed sensing for pediatric brain imaging
    Hyun Gi Kim
    Se Won Oh
    Dongyeob Han
    Jee Young Kim
    Gye Yeon Lim
    Neuroradiology, 2022, 64 : 2399 - 2407
  • [8] Accelerated 3D T2-weighted images using compressed sensing for pediatric brain imaging
    Kim, Hyun Gi
    Oh, Se Won
    Han, Dongyeob
    Kim, Jee Young
    Lim, Gye Yeon
    NEURORADIOLOGY, 2022, 64 (12) : 2399 - 2407
  • [9] MRI evaluation of soft tissue tumors: comparison of a fast, isotropic, 3D T2-weighted fat-saturated sequence with a conventional 2D T2-weighted fat-saturated sequence for tumor characteristics, resolution, and acquisition time
    Rodrigo de Castro Luna
    Neil M. Kumar
    Jan Fritz
    Shivani Ahlawat
    Laura M. Fayad
    European Radiology, 2022, 32 : 8670 - 8680
  • [10] MRI evaluation of soft tissue tumors: comparison of a fast, isotropic, 3D T2-weighted fat-saturated sequence with a conventional 2D T2-weighted fat-saturated sequence for tumor characteristics, resolution, and acquisition time
    de Castro Luna, Rodrigo
    Kumar, Neil M.
    Fritz, Jan
    Ahlawat, Shivani
    Fayad, Laura M.
    EUROPEAN RADIOLOGY, 2022, 32 (12) : 8670 - 8680