Proteomic analysis of serum, outflow dialysate and adsorbed protein onto dialysis membranes (polysulfone and PMMA) during hemodialysis treatment using SELDI-TOF-MS

被引:34
|
作者
Ishikawa, Isao
Chikazawa, Yoshihiro
Sato, Kazumasa
Nakagawa, Masaru
Imamura, Hidetsugu
Hayama, Satoshi
Yamaya, Hideki
Asaka, Mitsuhiro
Tomosugi, Naohisa
Yokoyama, Hitoshi
Matsumoto, Keiji
机构
[1] Asanogawa Gen Hosp, Div Nephrol, Dept Internal Med, Dialysis Ctr, Kanazawa, Ishikawa 9208621, Japan
[2] Kanazawa Med Univ, Kanazawa, Ishikawa, Japan
关键词
apolipoprotein; dialysis membrane; outflow dialysate; protein; proteome; SELDI-TOF-MS;
D O I
10.1159/000094779
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Aims: Alterations in the profiling of peptides and proteins in the serum, outflow dialysate and adsorbed protein on the dialysis membrane were investigated. Methods: Alterations in the protein profiling of routine hemodialysis using polysulfone (TS-UL) and PMMA (moderate flux membrane of polymethylmethacrylate: BK-U) in 8 patients and that of adsorption onto polysulfone and PMMA membranes in 4 patients were evaluated by SELDI-TOF-MS and ProteinChip array. Mass-to-charge ratios (m/z) between 2,000 and 120,000 were analyzed. Results:The protein with a relative intensity of m/z 11,730 measured by SELDI-TOF-MS was present in a small amount in the outflow dialysate and in a large amount in adsorption (identified as beta(2)-Microglobulin) onto PMMA membrane. Unexpectedly, 68 molecular masses of peptides that were adsorbed more onto polysulfone than onto PMMA membrane were observed. There were more peptides less than m/z 11,730 adsorbed onto polysulfone membrane than onto PMMA membrane. Dominant peaks, m/z 6,629 and 6,431 adsorbed onto polysulfone membrane were identified as apolipoprotein Cl and truncated apolipoprotein Cl, respectively. 37 proteins with molecular weights larger than m/z 11,730 showed greater filtration through PMMA membrane than through polysulfone membrane. 149 molecular masses that were adsorbed onto PMMA or more onto PMMA membrane than onto polysulfone membrane were observed. Conclusion: This experiment suggests that membrane adsorption is an important mechanism for the removal of middle-molecular-weight proteins by hemodialysis using not only PMMA membrane but also polysulfone membrane. Adsorption of peptide or protein onto a dialysis membrane may depend not only on the membrane material, but also on the peptide or protein. Copyright (c) 2006 S. Karger AG, Basel.
引用
收藏
页码:372 / 380
页数:9
相关论文
共 4 条
  • [1] Serum proteomic profiling analysis of chronic arsenic exposure by using SELDI-TOF-MS technology
    Zhao, Lijun
    Gao, Yanhui
    Yang, Yanmei
    Wei, Yudan
    Li, Yuanyuan
    Feng, Hongqi
    Wei, Wei
    Ding, Yunpeng
    Sun, Dianjun
    TOXICOLOGY LETTERS, 2010, 195 (2-3) : 155 - 160
  • [2] Proteomic profiling during atherosclerosis progression using SELDI-TOF-MS: Effect of darbepoetin treatment
    Dursun, Evrim
    Monari, Emanuela
    Cuoghi, Aurora
    Bergamini, Stefania
    Ozben, Beste
    Suleymanlar, Gultekin
    Tomasi, Aldo
    Ozben, Tomris
    ACTA HISTOCHEMICA, 2010, 112 (05) : 432 - 443
  • [3] Identification of a novel biomarker candidate, a 4.8-kDa peptide fragment from a neurosecretory protein VGF precursor, by proteomic analysis of cerebrospinal fluid from children with acute encephalopathy using SELDI-TOF-MS
    Takeshi Asano
    Shinya Koizumi
    Atsushi Takagi
    Takayuki Hatori
    Kentaroh Kuwabara
    Osamu Fujino
    Yoshitaka Fukunaga
    BMC Neurology, 11
  • [4] Identification of a novel biomarker candidate, a 4.8-kDa peptide fragment from a neurosecretory protein VGF precursor, by proteomic analysis of cerebrospinal fluid from children with acute encephalopathy using SELDI-TOF-MS
    Asano, Takeshi
    Koizumi, Shinya
    Takagi, Atsushi
    Hatori, Takayuki
    Kuwabara, Kentaroh
    Fujino, Osamu
    Fukunaga, Yoshitaka
    BMC NEUROLOGY, 2011, 11