Comparison of the physical characteristics of monodisperse non-ionic surfactant vesicles (NISV) prepared using different manufacturing methods

被引:17
|
作者
Obeid, Mohammad A. [1 ,2 ]
Gebril, Ayman M. [1 ]
Tate, Rothwelle J. [1 ]
Mullen, Alexander B. [1 ]
Ferro, Valerie A. [1 ]
机构
[1] Univ Strathclyde, Strathclyde Inst Pharm & Biomed Sci, 161 Cathedral St, Glasgow G4 0RE, Lanark, Scotland
[2] Yarmouk Univ, Fac Pharm, Irbid, Jordan
关键词
Non-ionic surfactant vesicles; Microfluidics; Thin-film hydration; Heating method; Drug delivery; Cytotoxicity; LIPID NANOPARTICLES; SKIN PERMEATION; NIOSOMES; DELIVERY; STABILITY; LIPOSOMES; TEMPERATURE; SLN(TM); SYSTEMS;
D O I
10.1016/j.ijpharm.2017.02.007
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Non-ionic surfactant vesicles (NISV) are synthetic membrane vesicles formed by self-assembly of a nonionic surfactant, often in a mixture with cholesterol and a charged chemical species. Different methods can be used to manufacture NISV, with the majority of these requiring bulk mixing of two phases. This mixing process is time-consuming and leads to the preparation of large and highly dispersed vesicles, which affects the consistency of the final product and could hinder subsequent regulatory approval. In this study, we have compared the physical characteristics of NISV prepared using two conventional methods (thin-film hydration method and heating method) with a recently introduced microfluidic method. The resulting particles from these methods were assessed for their physical characteristics and in vitro cytotoxicity. Through microfluidics, nano-sized NISV were prepared in seconds, through rapid and controlled mixing of two miscible phases (lipids dissolved in alcohol and an aqueous medium) in a microchannel, without the need of a size reduction step, as required for the conventional methods. Stability studies over two months showed the particles were stable regardless of the method of preparation and there were no differences in terms of EC50 on A375 and A2780 cell lines. However, this work demonstrates the flexibility and ease of applying lab-on-chip microfluidics for the preparation of NISV that could be used to significantly improve formulation research and development, by enabling the rapid manufacture of a consistent end-product, under controlled conditions. (C) 2017 Elsevier B. V. All rights reserved.
引用
收藏
页码:54 / 60
页数:7
相关论文
共 22 条
  • [21] A comparison of log Kow (n-octanol–water partition coefficient) values for non-ionic, anionic, cationic and amphoteric surfactants determined using predictions and experimental methods
    Geoff Hodges
    Charles Eadsforth
    Bart Bossuyt
    Alain Bouvy
    Marie-Helene Enrici
    Marc Geurts
    Matthias Kotthoff
    Eleanor Michie
    Dennis Miller
    Josef Müller
    Gunter Oetter
    Jayne Roberts
    Diederik Schowanek
    Ping Sun
    Joachim Venzmer
    Environmental Sciences Europe, 2019, 31
  • [22] A novel use of non-contact methods in analyzing the physical and technical surface characteristics of different materials using electromagnetic measurement techniques
    Nieslony, Piotr
    Krolczyk, Grzegorz M.
    Krolczyk, Jolanta Beata
    Gupta, Munish Kumar
    Bogdan-Chudy, Marta
    Grochalski, Karol
    Wojciechowski, Szymon
    Wieczorowski, Michal
    Maruda, Radoslaw W.
    MEASUREMENT, 2025, 241