Influence of placement depth and abutment connection pattern on bone remodeling around 1-stage implants: a prospective randomized controlled clinical trial

被引:41
作者
Palaska, Iro [1 ]
Tsaousoglou, Phoebus [2 ]
Vouros, Ioannis [2 ]
Konstantinidis, Antonis [2 ]
Menexes, George [3 ]
机构
[1] Tufts Univ, Sch Med, Mol Immunopharmacol & Drug Discovery Lab, Dept Integrat Physiol & Pathobiol, 150 Harisson Ave, Boston, MA USA
[2] Aristotle Univ Thessaloniki, Dept Prevent Dent Periodontol & Implant Biol, Sch Dent, GR-54006 Thessaloniki, Greece
[3] Aristotle Univ Thessaloniki, Dept Agron, Sch Agr, GR-54006 Thessaloniki, Greece
关键词
bone implant interactions; clinical assessment; clinical research; clinical trials; diagnosis; periodontology; SEE VOL. 29; CRESTAL BONE; DENTAL IMPLANTS; HISTOMETRIC EVALUATION; SUBMERGED IMPLANTS; MICROGAP LOCATION; TITANIUM IMPLANTS; ORAL IMPLANTS; OSSEOINTEGRATED IMPLANTS; INTERIMPLANT DISTANCES;
D O I
10.1111/clr.12527
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectivesThe aim of this study is to evaluate peri-implant marginal bone level changes in relation to crestal or subcrestal implant placement and type of fixture/abutment connection 3months after implant placement. Materials and methodsThe duration of the study was 3months. A total of 105 implants were placed in 81 subjects following a one-stage surgical procedure and assigned into four groups. In the first and second groups, implants with a screwed tapered internal connection were placed subcrestally and crestally, respectively, while in the third and fourth groups, implants with an internal conical seal connection were similarly placed. Clinical recordings and standardized periapical digital radiographs were taken the day of implantation and 3months later, before placement of the final prosthetic restoration. The modified plaque index (mPLI), modified gingival index (mGI), and probing depths (PD) were recorded at four sites around each implant, and the vertical distance between fixture/abutment junction and alveolar crest at the mesial and distal sites of each implant utilizing subtractive radiography were all measured on placement and at 3months. ResultsThere was no statistically significant difference between the four groups for PD. The highest values of mPLI and mGI were recorded for Group 2. The mean (SE) peri-implant bone loss was recorded as follows: Group 1: 0.68 +/- 0.07mm, Group 2: 0.79 +/- 0.06mm, Group 3: 0.49 +/- 0.06mm, and Group 4: 0.40 +/- 0.07mm. The statistical analysis revealed significant differences in bone resorption between groups with different abutment connections. ConclusionsThe connection between fixture/abutment rather than vertical implant placement in relation to alveolar bone level seems to affect peri-implant marginal bone resorption.
引用
收藏
页码:E47 / E56
页数:10
相关论文
共 98 条
  • [1] The peri-implant hard and soft tissues at different implant systems - A comparative study in the dog
    Abrahamsson, I
    Berglundh, T
    Wennstrom, J
    Lindhe, J
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (03) : 212 - 219
  • [2] The mucosal attachment at different abutments - An experimental study in dogs
    Abrahamsson, I
    Berglundh, T
    Glantz, PO
    Lindhe, J
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1998, 25 (09) : 721 - 727
  • [3] A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW
    ADELL, R
    LEKHOLM, U
    ROCKLER, B
    BRANEMARK, PI
    [J]. INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06): : 387 - 416
  • [4] ADELL R, 1990, International Journal of Oral and Maxillofacial Implants, V5, P347
  • [5] Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
  • [6] Is Marginal Bone Loss around Oral Implants the Result of a Provoked Foreign Body Reaction?
    Albrektsson, Tomas
    Dahlin, Christer
    Jemt, Torsten
    Sennerby, Lars
    Turri, Alberto
    Wennerberg, Ann
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2014, 16 (02) : 155 - 165
  • [7] Microbial leakage through the implant-abutment interface of morse taper implants in vitro
    Aloise, Joao Pedro
    Curcio, Ricardo
    Laporta, Marcia Zorello
    Rossi, Liliane
    Alvares da Silva, Adriana Madeira
    Rapoport, Abrao
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (03) : 328 - 335
  • [8] Stress Distribution in the Abutment and Retention Screw of a Single Implant Supporting a Prosthesis with Platform Switching
    Alvarez-Arenal, Angel
    Segura-Mori, Luis
    Gonzalez-Gonzalez, Ignacio
    Gago, Angel
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (03) : E112 - E121
  • [9] Peri-implant marginal bone level: a systematic review and meta-analysis of studies comparing platform switching versus conventionally restored implants
    Annibali, Susanna
    Bignozzi, Isabella
    Cristalli, Maria Paola
    Graziani, Filippo
    La Monaca, Gerardo
    Polimeni, Antonella
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 2012, 39 (11) : 1097 - 1113
  • [10] Platform Switching for Marginal Bone Preservation Around Dental implants: A Systematic Review and Meta-Analysis
    Atieh, Momen A.
    Ibrahim, Hadeel M.
    Atieh, Ahmad H.
    [J]. JOURNAL OF PERIODONTOLOGY, 2010, 81 (10) : 1350 - 1366