摘要
Quantity quotient (QQ) reporting has been proposed by several authors to improve or support the present situation of presenting quantitative laboratory results. This proposal is based on a concept (symmetrical model) known from the intelligence quotient, which was developed to make intelligence tests comparable. In laboratory medicine, however, most measurands follow a non-symmetrical (skewed) distribution, leading to a compression of the QQ values at the lower end of the reference interval. This effect can be avoided by several alternatives. Three models considering non-symmetrical distributions are compared with the symmetrical model in the present study. The corresponding algorithms can be easily handled on the Excel platform. Graphical presentation of the QQ allows a quick overview of test results if they occur in a large number.
引用
收藏
页码:1921 / 1926
页数:6
相关论文
共 12 条
[1]   Indirect reference intervals of plasma and serum thyrotropin (TSH) concentrations from intra-laboratory data bases from several German and Italian medical centres [J].
Arzideh, Farhad ;
Wosniok, Werner ;
Haeckel, Rainer .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (04) :659-664
[2]  
Clinical and Laboratory Standards Institute, 2013, EP26A CLIN LAB STAND, P13
[3]   LOGNORMAL DISTRIBUTIONS [J].
GADDUM, JH .
NATURE, 1945, 156 (3964) :463-466
[4]   Pre-analytical variation of some haematological quantities [J].
Garcia-Panyella, Mariona ;
Padro-Miquel, Ariadna ;
Dot-Bach, Dolors ;
Fuentes-Arderiu, Xavier .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2008, 46 (08) :1168-1170
[5]   Permissible limits for uncertainty of measurement in laboratory medicine [J].
Haeckel, Rainer ;
Wosniok, Werner ;
Gurr, Ebrhard ;
Peil, Burkhard .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2015, 53 (08) :1161-1171
[6]   Observed, unknown distributions of clinical chemical quantities should be considered to be log-normal: a proposal [J].
Haeckel, Rainer ;
Wosniok, Werner .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (10) :1393-1396
[7]   Standardization of laboratory results: quotient reporting [J].
Haeckel, Rainer ;
Wosniok, Werner ;
Hoffman, Georg .
LABORATORIUMSMEDIZIN-JOURNAL OF LABORATORY MEDICINE, 2010, 34 (02) :95-98
[8]   Quantity quotient reporting. A proposal for a standardized presentation of laboratory results [J].
Haeckel, Rainer ;
Wosniok, Werner .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2009, 47 (10) :1203-1206
[9]   SOFTWARE FOR ILLUSTRATIVE PRESENTATION OF BASIC CLINICAL CHARACTERISTICS OF LABORATORY TESTS - GRAPHROC FOR WINDOWS [J].
KAIRISTO, V ;
POOLA, A .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1995, 55 :43-60
[10]   PROPOSAL FOR A MORE UNIFORM OUTPUT IN LABORATORY DATA [J].
LO, JS ;
KELLEN, JA .
CLINICA CHIMICA ACTA, 1972, 41 (01) :239-&