Fast Image Reconstruction With L2-Regularization

被引:133
作者
Bilgic, Berkin [1 ,2 ]
Chatnuntawech, Itthi [1 ]
Fan, Audrey P. [1 ]
Setsompop, Kawin [2 ,3 ]
Cauley, Stephen F. [2 ]
Wald, Lawrence L. [2 ,3 ,4 ]
Adalsteinsson, Elfar [1 ,4 ]
机构
[1] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[2] Massachusetts Gen Hosp, Dept Radiol, AA Martinos Ctr Biomed Imaging, Charlestown, MA USA
[3] Harvard Univ, Sch Med, Boston, MA USA
[4] MIT, Harvard Mit Div Hlth Sci & Technol, Cambridge, MA 02139 USA
关键词
regularization; susceptibility mapping; diffusion imaging; spectroscopic imaging; lipid suppression; BRAIN IRON; HIGH-FIELD; SUSCEPTIBILITY; MRI; REGULARIZATION; VALIDATION; INVERSION; MULTIPLE; MAP;
D O I
10.1002/jmri.24365
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We introduce L2-regularized reconstruction algorithms with closed-form solutions that achieve dramatic computational speed-up relative to state of the art L1- and L2-based iterative algorithms while maintaining similar image quality for various applications in MRI reconstruction. Materials and Methods: We compare fast L2-based methods to state of the art algorithms employing iterative L1- and L2-regularization in numerical phantom and in vivo data in three applications; (i) Fast Quantitative Susceptibility Mapping (QSM), (ii) Lipid artifact suppression in Magnetic Resonance Spectroscopic Imaging (MRSI), and (iii) Diffusion Spectrum Imaging (DSI). In all cases, proposed L2-based methods are compared with the state of the art algorithms, and two to three orders of magnitude speed up is demonstrated with similar reconstruction quality. Results: The closed-form solution developed for regularized QSM allows processing of a three-dimensional volume under 5 s, the proposed lipid suppression algorithm takes under 1 s to reconstruct single-slice MRSI data, while the PCA based DSI algorithm estimates diffusion propagators from undersampled q-space for a single slice under 30 s, all running in Matlab using a standard workstation. Conclusion: For the applications considered herein, closed-form L2-regularization can be a faster alternative to its iterative counterpart or L1-based iterative algorithms, without compromising image quality.
引用
收藏
页码:181 / 191
页数:11
相关论文
共 37 条
[11]   High-field MRI of brain cortical substructure based on signal phase [J].
Duyn, Jeff H. ;
van Gelderen, Peter ;
Li, Tie-Qiang ;
de Zwart, Jacco A. ;
Koretsky, Alan P. ;
Fukunaga, Masaki .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2007, 104 (28) :11796-11801
[12]   Comparison of inversion recovery preparation schemes for lipid suppression in 1H MRSI of human brain [J].
Ebel, A ;
Govindaraju, V ;
Maudsley, AA .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (05) :903-908
[13]   Phase-based regional oxygen metabolism (PROM) using MRI [J].
Fan, Audrey P. ;
Benner, Thomas ;
Bolar, Divya S. ;
Rosen, Bruce R. ;
Adalsteinsson, Elfar .
MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (03) :669-678
[14]   Sparse signal reconstruction from limited data using FOCUSS: A re-weighted minimum norm algorithm [J].
Gorodnitsky, IF ;
Rao, BD .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1997, 45 (03) :600-616
[15]   H-1-NMR CHEMICAL-SHIFT SELECTIVE (CHESS) IMAGING [J].
HAASE, A ;
FRAHM, J ;
HANICKE, W ;
MATTHAEI, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (04) :341-344
[16]   Improved diffusion imaging through SNR-enhancing joint reconstruction [J].
Haldar, Justin P. ;
Wedeen, Van J. ;
Nezamzadeh, Marzieh ;
Dai, Guangping ;
Weiner, Michael W. ;
Schuff, Norbert ;
Liang, Zhi-Pei .
MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) :277-289
[17]  
Hansen P. C., 1987, RANK DEFICIENT DISCR
[18]  
Hansen PC, 2001, ADV COMP BIOENG, V5, P119
[19]   Removal of lipid artifacts in H-1 spectroscopic imaging by data extrapolation [J].
Haupt, CI ;
Schuff, N ;
Weiner, MW ;
Maudsley, AA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) :678-687
[20]   Improved optimization for the robust and accurate linear registration and motion correction of brain images [J].
Jenkinson, M ;
Bannister, P ;
Brady, M ;
Smith, S .
NEUROIMAGE, 2002, 17 (02) :825-841