Estimating Soil Organic Carbon Content with Visible-Near-Infrared (Vis-NIR) Spectroscopy

被引:45
作者
Gao, Yin [1 ,2 ,3 ]
Cui, Lijuan [4 ]
Lei, Bing [5 ]
Zhai, Yanfang [6 ]
Shi, Tiezhu [2 ,3 ]
Wang, Junjie [2 ,3 ]
Chen, Yiyun [2 ,3 ]
He, Hui [7 ]
Wu, Guofeng [8 ,9 ,10 ]
机构
[1] Natl Geomat Ctr China, Beijing 100830, Peoples R China
[2] Wuhan Univ, Sch Resource & Environm Sci, Wuhan 430079, Peoples R China
[3] Wuhan Univ, Key Lab Geog Informat Syst, Minist Educ, Wuhan 430079, Peoples R China
[4] Chinese Acad Forestry, Inst Wetland Res, Beijing 100091, Peoples R China
[5] Natl Adm Surveying Mapping & Geoinformat China, Satellite Surveying & Mapping Applicat Ctr, Beijing 100830, Peoples R China
[6] Chongqing Inst Surveying & Mapping, Chongqing 400014, Peoples R China
[7] Star Map Press, Beijing 100088, Peoples R China
[8] Shenzhen Univ, Key Lab Geoenvironm Monitoring Coastal Zone, Natl Adm Surveying Mapping & Geoinformat, Shenzhen 518060, Peoples R China
[9] Shenzhen Univ, Shenzhen Key Lab Spatial Smart Sensing & Serv, Shenzhen 518060, Peoples R China
[10] Shenzhen Univ, Coll Life Sci, Shenzhen 518060, Peoples R China
基金
中国国家自然科学基金;
关键词
Soil organic carbon; Visible-near-infrared; Vis-NIR; Support vector machine regression; Partial least squares regression; Spectral preprocessing; LEAST-SQUARE REGRESSION; REFLECTANCE SPECTROSCOPY; QUANTITATIVE-ANALYSIS; CHEMICAL-PROPERTIES; PREDICTION; FIELD; CALIBRATION; NITROGEN; MODELS; SCALE;
D O I
10.1366/13-07031
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The selection of a calibration method is one of the main factors influencing measurement accuracy with visible-near-infrared (Vis-NIR, 350-2500 nm) spectroscopy. This study, based on both air-dried unground (DU) and air-dried ground (DG) soil samples, used nine spectral preprocessing methods and their combinations, with the aim to compare the commonly used partial least squares regression (PLSR) method with the new machine learning method of support vector machine regression (SVMR) to find a robust method for soil organic carbon (SOC) content estimation, and to further explore an effective Vis-NIR spectral preprocessing strategy. In total, 100 heterogeneous soil samples collected from Southeast China were used as the dataset for the model calibration and independent validation. The determination coefficient (R-2), root mean square error (RMSE), residual prediction deviation (RPD), and ratio of performance to interquartile range were used for the model evaluation. The results of this study show that both the PLSR and SVMR models were significantly improved by the absorbance transformation (LOG), standard normal variate with wavelet de-trending (SW), first derivative (FD), and mean centering (MC) spectral preprocessing methods and their combinations. SVMR obtained optimal models for both the DU and DG soil, with R-2, RMSE, and RPD values of 0.72, 2.48 g/kg, and 1.83 for DU soil and 0.86, 1.84 g/kg, and 2.60 for DG soil, respectively. Among all the PLSR and SVMR models, SVMR showed a more stable performance than PLSR, and it also outperformed PLSR, with a smaller mean RMSE of 0.69 g/kg for DU soil and 0.50 g/kg for DG soil. This study concludes that PLSR is an effective linear algorithm, but it might not be sufficient when dealing with a nonlinear relationship, and SVMR turned out to be a more suitable nonlinear regression method for SOC estimation. Effective SOC estimation was obtained based on the DG soil samples, but the accurate estimation of SOC with DU soil samples needs to be further explored. In addition, LOG, SW, FD, and MC are valuable spectral preprocessing methods for Vis-NIR optimization, and choosing two of them (except for FD + SW and LOG + FD) in a simple combination is a good way to get acceptable results.
引用
收藏
页码:712 / 722
页数:11
相关论文
共 40 条
[11]   PARTIAL LEAST-SQUARES METHODS FOR SPECTRAL ANALYSES .1. RELATION TO OTHER QUANTITATIVE CALIBRATION METHODS AND THE EXTRACTION OF QUALITATIVE INFORMATION [J].
HAALAND, DM ;
THOMAS, EV .
ANALYTICAL CHEMISTRY, 1988, 60 (11) :1193-1202
[12]  
Hill J, 2010, PRECISION CROP PROTECTION - THE CHALLENGE AND USE OF HETEROGENEITY, P67, DOI 10.1007/978-90-481-9277-9_5
[13]   Estimation of some chemical properties of an agricultural soil by spectroradiometric measurements [J].
Jarmer, T. ;
Vohland, M. ;
Lilienthal, H. ;
Schnug, E. .
PEDOSPHERE, 2008, 18 (02) :163-170
[14]   Calibration of visible and near infrared spectroscopy for soil analysis at the field scale on three European farms [J].
Kuang, B. ;
Mouazen, A. M. .
EUROPEAN JOURNAL OF SOIL SCIENCE, 2011, 62 (04) :629-636
[15]   Measuring carbon dynamics in field soils using soil spectral reflectance: prediction of maize root density, soil organic carbon and nitrogen content [J].
Kusumo, Bambang Hari ;
Hedley, Mike J. ;
Hedley, Carolyn B. ;
Tuohy, Mike P. .
PLANT AND SOIL, 2011, 338 (1-2) :233-245
[16]   Use of near-infrared reflectance spectroscopy in prediction of heavy metals in freshwater sediment by their association with organic matter [J].
Malley, DF ;
Williams, PC .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (12) :3461-3467
[17]   Simulated in situ characterization of soil organic and inorganic carbon with visible near-infrared diffuse reflectance spectroscopy [J].
Morgan, Cristine L. S. ;
Waiser, Travis H. ;
Brown, David J. ;
Hallmark, C. Tom .
GEODERMA, 2009, 151 (3-4) :249-256
[18]   Comparison among principal component, partial least squares and back propagation neural network analyses for accuracy of measurement of selected soil properties with visible and near infrared spectroscopy [J].
Mouazen, A. M. ;
Kuang, B. ;
De Baerdemaeker, J. ;
Ramon, H. .
GEODERMA, 2010, 158 (1-2) :23-31
[19]   Soil carbon mapping using on-the-go near infrared spectroscopy, topography and aerial photographs [J].
Munoz, Juan D. ;
Kravchenko, Alexandra .
GEODERMA, 2011, 166 (01) :102-110
[20]   Review of the most common pre-processing techniques for near-infrared spectra [J].
Rinnan, Asmund ;
van den Berg, Frans ;
Engelsen, Soren Balling .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2009, 28 (10) :1201-1222