Real-time proton beam range monitoring by means of prompt-gamma detection with a collimated camera

被引:55
作者
Roellinghoff, F. [1 ,2 ,3 ,4 ,5 ,6 ,7 ]
Benilov, A. [7 ]
Dauvergne, D. [1 ,2 ,3 ]
Dedes, G. [1 ,2 ,3 ]
Freud, N. [4 ,5 ,6 ]
Janssens, G. [7 ]
Krimmer, J. [1 ,2 ,3 ]
Letang, J. M. [4 ,5 ,6 ]
Pinto, M. [1 ,2 ,3 ]
Prieels, D. [7 ]
Ray, C. [1 ,2 ,3 ]
Smeets, J. [7 ]
Stichelbaut, F. [7 ]
Testa, E. [1 ,2 ,3 ]
机构
[1] Univ Lyon, IPNL, F-69003 Lyon, France
[2] Univ Lyon 1, F-69622 Villeurbanne, France
[3] CNRS IN2P3, UMR 5822, F-69622 Villeurbanne, France
[4] Univ Lyon, CREATIS, F-69622 Lyon, France
[5] Univ Lyon 1, Ctr Leon Berard, France
[6] INSA Lyon, CNRS UMR 5220, INSERMU1044, Ctr Leon Berard, France
[7] Ion Beam Applicat SA, B-1348 Louvain, Belgium
关键词
protontherapy; prompt gamma; time-of-flight; VERIFICATION; PATIENT; THERAPY;
D O I
10.1088/0031-9155/59/5/1327
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Prompt-gamma profile was measured at WPE-Essen using 160 MeV protons impinging a movable PMMA target. A single collimated detector was used with time-of-flight (TOF) to reduce the background due to neutrons. The target entrance rise and the Bragg peak falloff retrieval precision was determined as a function of incident proton number by a fitting procedure using independent data sets. Assuming improved sensitivity of this camera design by using a greater number of detectors, retrieval precisions of 1 to 2mm (rms) are expected for a clinical pencil beam. TOF improves the contrast-to-noise ratio and the performance of the method significantly.
引用
收藏
页码:1327 / 1338
页数:12
相关论文
共 21 条
[1]   Real-time prompt gamma monitoring in spot-scanning proton therapy using imaging through a knife-edge-shaped slit [J].
Bom, Victor ;
Joulaeizadeh, Leila ;
Beekman, Freek .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (02) :297-308
[2]  
Lopes PC, 2012, IEEE NUCL SCI CONF R, P3864
[3]  
Diblen F, 2012, IEEE NUCL SCI CONF R, P3887
[4]  
Fiedler F, 2011, IEEE NUCL SCI CONF R, P4453, DOI 10.1109/NSSMIC.2011.6152493
[5]   On the effectiveness of ion range determination from in-beam PET data [J].
Fiedler, Fine ;
Shakirin, Georgy ;
Skowron, Judith ;
Braess, Henning ;
Crespo, Paulo ;
Kunath, Daniela ;
Pawelke, Joerg ;
Poenisch, Falk ;
Enghardt, Wolfgang .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (07) :1989-1998
[6]   GATE as a GEANT4-based Monte Carlo platform for the evaluation of proton pencil beam scanning treatment plans [J].
Grevillot, L. ;
Bertrand, D. ;
Dessy, F. ;
Freud, N. ;
Sarrut, D. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (13) :4223-4244
[7]   Machine learning-based patient specific prompt-gamma dose monitoring in proton therapy [J].
Gueth, P. ;
Dauvergne, D. ;
Freud, N. ;
Letang, J. M. ;
Ray, C. ;
Testa, E. ;
Sarrut, D. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (13) :4563-4577
[8]  
JONGEN Y, 2003, 39 PART THER COOP GR
[9]   Pinhole Camera Measurements of Prompt Gamma-rays for Detection of Beam Range Variation in Proton Therapy [J].
Kim, Dogyun ;
Yim, Heejung ;
Kim, Jong-Won .
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2009, 55 (04) :1673-1676
[10]   In vivo proton range verification: a review [J].
Knopf, Antje-Christin ;
Lomax, Antony .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (15) :131-160