New Method for Shallow and Deep Trap Distribution Analysis in Oil Impregnated Insulation Paper Based on the Space Charge Detrapping

被引:24
作者
Hao, Jian [1 ]
Zou, Runhao [1 ]
Liao, Ruijin [1 ]
Yang, Lijun [1 ]
Liao, Qiang [2 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400044, Peoples R China
[2] Chongqing Univ, Coll Power Engn, Chongqing 400044, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金; 中国博士后科学基金;
关键词
space charge; trap distribution; oil impregnated insulation paper; charge detrapping; electrical field; oil ageing; LOW-DENSITY POLYETHYLENE; BEHAVIOR; DC; TEMPERATURES; VOLTAGES;
D O I
10.3390/en11020271
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Space charge has close relation with the trap distribution in the insulation material. The phenomenon of charges trapping and detrapping has attracted significant attention in recent years. Space charge and trap parameters are effective parameters for assessing the ageing condition of the insulation material qualitatively. In this paper, a new method for calculating trap distribution based on the double exponential fitting analysis of charge decay process and its application on characterizing the trap distribution of oil impregnated insulation paper was investigated. When compared with the common first order exponential fitting analysis method, the improved dual-level trap method could obtain the energy level range and density of both shallow traps and deep traps, simultaneously. Space charge decay process analysis of the insulation paper immersed with new oil and aged oil shows that the improved trap distribution calculation method can distinguish the physical defects and chemical defects. The trap density shows an increasing trend with the oil ageing, especially for the deep traps mainly related to chemical defects. The greater the energy could be filled by the traps, the larger amount of charges could be trapped, especially under higher electric field strength. The deep trap energy level and trap density could be used to characterize ageing. When one evaluates the ageing condition of oil-paper insulation using trap distribution parameters, the influence of oil performance should not be ignored.
引用
收藏
页数:16
相关论文
共 37 条
  • [1] [Anonymous], CIGRE SC A2 D1 JOINT
  • [2] Chen C. Z., 1975, INSULATION OIL ITS O
  • [3] Charge trapping and detrapping in polymeric materials
    Chen, George
    Xu, Zhiqiang
    [J]. JOURNAL OF APPLIED PHYSICS, 2009, 106 (12)
  • [4] Space charge evolution in oil-paper insulation for DC cables application
    Ciobanu, R
    Schreiner, C
    Pfeiffer, W
    Baraboi, B
    [J]. PROCEEDINGS OF THE 2002 IEEE 14TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS, 2002, : 321 - 324
  • [5] Kinetic analysis and modelling of the ageing process for Kraft paper aged in natural ester dielectric fluid
    Ding, H. -Z.
    Wang, Z. D.
    [J]. 2006 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2006, : 505 - 508
  • [6] Dissado L. A., 1992, ELECT DEGRADATION BR, V9, P620
  • [7] Du BX, 2016, IEEE T DIELECT EL IN, V23, P2059, DOI [10.1109/TDEI.2016.005607, 10.1109/TDEI.2016.7556479]
  • [8] Interface Charge Behavior of Multi-layer Oil-Paper Insulation under DC and Polarity Reversal Voltages
    Du, B. X.
    Zhang, J. G.
    Liu, D. S.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (05) : 2628 - 2636
  • [9] Eager G. S., 1967, P IEEE C EL INS DIEL, P166
  • [10] Influence of Moisture on Space Charge Dynamics in Multilayer Oil-Paper Insulation
    Hao, Jian
    Chen, George
    Liao, Ruijin
    Yang, Lijun
    Tang, Chao
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (04) : 1456 - 1464