Effect of pH and ionic strength on boron removal by RO membranes

被引:86
|
作者
Oo, Maung Htun [2 ,3 ]
Song, Lianfa [1 ]
机构
[1] Texas Tech Univ, Dept Civil & Environm Engn, Lubbock, TX 79404 USA
[2] Natl Univ Singapore, Dept Civil Engn, Singapore 117576, Singapore
[3] Singapore Util Int Pte Ltd, Ctr Adv Water Technol, Singapore 608575, Singapore
关键词
Boron removal; Ionic strength; Zeta potential; Seawater desalination; RO membranes; REVERSE-OSMOSIS; SEAWATER DESALINATION; WATER; NANOFILTRATION; ELIMINATION; ADSORPTION; SYSTEMS; RESIN; SEA;
D O I
10.1016/j.desal.2008.06.025
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
While removal efficiency of most components in water by RO membranes is very satisfactory, the removal of some trace elements such as boron by RO membranes, especially those with long service life, is relatively low. The interplay between pH and ionic strength is believed to be the key to understand the boron removal by RO membranes. Boron, with pK(a) of 9.25, in water at low concentration is normally in the form of boric acid (B(OH)(3)) at neutral pH and it is dissociated into negatively charged borate (B(OH)(4)(-)) form at high pH. Correspondingly, more than 99% boron removal by RO membranes can be achieved at high pH. However, it usually drops to 40-80% at neutral pH. It has been reported in the literature that higher ionic strength is theoretically suggested to be the cause of lower pK(a) value. This means we can expect better boron removal at lower pH with higher ionic strength (salinity). However, the result in this study revealed that boron removal at higher salinity was lower than that at lower salinity and same pH. Boron removals at pH 10 for CPA2 membrane were found to be 81% and 71% at 500 mg/L and 15,000 mg/L NaCl, respectively. At pH 9, boron removals were 61% and 45% at 500 mg/L and 15,000 mg/L NaCl, respectively.
引用
收藏
页码:605 / 612
页数:8
相关论文
共 50 条
  • [1] Coupling effects of feed solution pH and ionic strength on the rejection of boron by NF/RO membranes
    Tu, Kha L.
    Nghiem, Long D.
    Chivas, Allan R.
    CHEMICAL ENGINEERING JOURNAL, 2011, 168 (02) : 700 - 706
  • [2] Boron removal and zeta potential of RO membranes: impact of pH and salinity
    Oo, Maung Htun
    Ong, Say Leong
    DESALINATION AND WATER TREATMENT, 2012, 39 (1-3) : 83 - 87
  • [3] EFFECT OF PH AND IONIC-STRENGTH ON BORON ADSORPTION BY PYROPHYLLITE
    KEREN, P
    SPARKS, DL
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 1994, 58 (04) : 1095 - 1100
  • [4] Boron removal in new generation reverse osmosis (RO) membranes using two-pass RO without pH adjustment
    Farhat, Ali
    Ahmad, Farrukh
    Hilal, Nidal
    Arafat, Hassan A.
    DESALINATION, 2013, 310 : 50 - 59
  • [5] Removal of boron from geothermal water by RO system-II-effect of pH
    Yavuz, Emre
    Arar, Ozgur
    Yuksel, Mithat
    Yuksel, Umran
    Kabay, Nalan
    DESALINATION, 2013, 310 : 135 - 139
  • [6] Removal of natural organic matter by cationic and anionic polyacrylonitrile membranes. The effect of pressure, ionic strength and pH
    Sentana, I.
    De La Rubia, M. A.
    Rodriguez, M.
    Sentana, E.
    Prats, D.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2009, 68 (03) : 305 - 311
  • [7] Surface engineering with ionic polymers on membranes for boron removal
    Zhang, Xiting
    Fang, Chenyi
    Chen, J. Paul
    Zhang, Sui
    FRONTIERS OF CHEMICAL SCIENCE AND ENGINEERING, 2024, 18 (05)
  • [8] Implication of zeta potential at different salinities on boron removal by RO membranes
    Oo, Maung Htun
    Ong, Say Leong
    JOURNAL OF MEMBRANE SCIENCE, 2010, 352 (1-2) : 1 - 6
  • [9] Effect of pH and Pressure on Uranium Removal from Drinking Water Using NF/RO Membranes
    Schulte-Herbruggen, Helfrid M. A.
    Semiao, Andrea J. C.
    Chaurand, Perrine
    Graham, Margaret C.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2016, 50 (11) : 5817 - 5824
  • [10] Boron removal in RO seawater desalination
    Taniguchi, M
    Fusaoka, Y
    Nishikawa, T
    Kurihara, M
    DESALINATION, 2004, 167 (1-3) : 419 - 426