Processing difficulties and instability of carbohydrate microneedle arrays

被引:119
作者
Donnelly, Ryan F. [1 ]
Morrow, Desmond I. J. [1 ]
Singh, Thakur R. R. [1 ]
Migalska, Katarzyna [1 ]
McCarron, Paul A. [2 ]
O'Mahony, Conor [3 ]
Woolfson, A. David [1 ]
机构
[1] Queens Univ Belfast, Ctr Med Biol, Sch Pharm, Belfast BT9 7BL, Antrim, North Ireland
[2] Univ Ulster, Dept Pharm & Pharmaceut Sci, Coleraine BT52 1SA, Londonderry, North Ireland
[3] Tyndall Natl Inst, Cork, Ireland
基金
英国生物技术与生命科学研究理事会; 爱尔兰科学基金会;
关键词
Carbohydrate; galactose; microneedles; processing; stability; TRANSDERMAL DELIVERY; PERCUTANEOUS-ABSORPTION; PHARMACEUTICAL ANALYSIS; POLYMER MICRONEEDLES; INSULIN DELIVERY; MODEL; IMMUNIZATION; FABRICATION; EFFICIENT; NEEDLES;
D O I
10.1080/03639040902882280
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Background: A number of reports have suggested that many of the problems currently associated with the use of microneedle (MN) arrays for transdermal drug delivery could be addressed by using drug-loaded MN arrays prepared by moulding hot melts of carbohydrate materials. Methods: In this study, we explored the processing, handling, and storage of MN arrays prepared from galactose with a view to clinical application. Results: Galactose required a high processing temperature (160 degrees C), and molten galactose was difficult to work with. Substantial losses of the model drugs 5-aminolevulinic acid ( ALA) and bovine serum albumin were incurred during processing. While relatively small forces caused significant reductions in MN height when applied to an aluminium block, this was not observed during their relatively facile insertion into heat-stripped epidermis. Drug release experiments using ALA-loaded MN arrays revealed that less than 0.05% of the total drug loading was released across a model silicone membrane. Similarly, only low amounts of ALA ( approximately 0.13%) and undetectable amounts of bovine serum albumin were delivered when galactose arrays were combined with aqueous vehicles. Microscopic inspection of the membrane following release studies revealed that no holes could be observed in the membrane, indicating that the partially dissolved galactose sealed the MN-induced holes, thus limiting drug delivery. Indeed, depth penetration studies into excised porcine skin revealed that there was no significant increase in ALA delivery using galactose MN arrays, compared to control (P value < 0.05). Galactose MNs were unstable at ambient relative humidities and became adhesive. Conclusion: The processing difficulties and instability encountered in this study are likely to preclude successful clinical application of carbohydrate MNs. The findings of this study are of particular importance to those in the pharmaceutical industry involved in the design and formulation of transdermal drug delivery systems based on dissolving MN arrays. It is hoped that we have illustrated conclusively the difficulties inherent in the processing and storage of carbohydrate-based dissolving MNs and that those in the industry will now follow alternative approaches.
引用
收藏
页码:1242 / 1254
页数:13
相关论文
共 35 条
[1]  
[Anonymous], 1996, INT C HARM TECHN REQ
[2]  
Cilurzo F, 2007, AAPS PHARMSCITECH, V8
[3]   Transdermal delivery of desmopressin using a coated microneedle array patch system [J].
Cormier, M ;
Johnson, B ;
Ameri, M ;
Nyam, K ;
Libiran, L ;
Zhang, DD ;
Daddona, P .
JOURNAL OF CONTROLLED RELEASE, 2004, 97 (03) :503-511
[4]  
Coulman Sion A., 2006, Current Drug Delivery, V3, P65, DOI 10.2174/156720106775197510
[5]   Hollow metal microneedles for insulin delivery to diabetic rats [J].
Davis, SP ;
Martanto, W ;
Allen, MG ;
Prausnitz, MR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (05) :909-915
[6]   Pharmaceutical analysis of 5-aminolevulinic acid in solution and in tissues [J].
Donnelly, RF ;
Morrow, DIJ ;
McCarron, PA ;
Juzenas, P ;
Woolfson, AD .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 2006, 82 (01) :59-71
[7]   Silicon micromachined hollow microneedles for transdermal liquid transport [J].
Gardeniers, HJGE ;
Luttge, R ;
Berenschot, EJW ;
de Boer, MJ ;
Yeshurun, SY ;
Hefetz, M ;
van't Oever, R ;
van den Berg, A .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2003, 12 (06) :855-862
[8]   Microfabricated microneedles: A novel approach to transdermal drug delivery [J].
Henry, S ;
McAllister, DV ;
Allen, MG ;
Prausnitz, MR .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1998, 87 (08) :922-925
[9]   Sustained-release self-dissolving micropiles for percutaneous absorption of insulin in mice [J].
Ito, Yukako ;
Hagiwara, Eiji ;
Saeki, Atsushi ;
Sugioka, Nobuyuki ;
Takada, Kanji .
JOURNAL OF DRUG TARGETING, 2007, 15 (05) :323-326
[10]   Feasibility of microneedles for percutaneous absorption of insulin [J].
Ito, Yukako ;
Hagiwara, Eiji ;
Saeki, Atsushi ;
Sugioka, Nobuyuki ;
Takada, Kanji .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2006, 29 (01) :82-88