Contact force and force-time integral in atrial radiofrequency ablation predict transmurality of lesions

被引:103
作者
Squara, Fabien [1 ,2 ]
Latcu, Decebal Gabriel [1 ]
Massaad, Youssef [1 ]
Mahjoub, Marouane [1 ]
Bun, Sok-Sithikun [1 ]
Saoudi, Nadir [1 ]
机构
[1] Ctr Hosp Princesse Grace, MC-98000 Monaco, Monaco
[2] Pasteur Univ Hosp, Dept Cardiol, F-06000 Nice, France
来源
EUROPACE | 2014年 / 16卷 / 05期
关键词
Ablation; Atrial fibrillation; Contact force; Force-time integral; Transmural lesion; CATHETER ABLATION; FIBRILLATION; ELECTROGRAM;
D O I
10.1093/europace/euu068
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
During radiofrequency (RF) delivery, lesion volume is highly dependent on contact force (CF). It has recently been shown that changes of bipolar electrogram (EGM) predict transmurality. We hypothesized that there is a correlation between CF and EGM criteria of transmural lesion (TL) during RF. We prospectively studied consecutive 512 RF applications from atrial fibrillation ablation procedures. A force-sensing ablation catheter (Tacticath(A (R)), Endosense) was used to continuously measure CF and force-time integral (FTI) during each RF application. Distal bipolar EGM was analysed before, during, and after each RF application. Depending on initial EGM morphology, transmurality of lesions was defined by: (i) disappearance of the positivity after RF when there was QR morphology, (ii) diminution > 75% of the positivity when there was QRS morphology, or (iii) disappearance of the R' positivity when there was RSR' morphology. Electrogram criteria were validated by electrophysiologists blinded to force measurements. Force-time integral was higher in TL than in non-transmural lesions (NTLs): 652 +/- 248 vs. 212 +/- 140 gs (P < 0.001). Mean CF per RF pulse was higher in TL than in NTL: 26.3 +/- 12.5 vs. 11.3 +/- 10.3 g (P < 0.001). The best cut-off to predict TL was an FTI a parts per thousand yen 392 gs [sensitivity 0.89, specificity (Sp) 0.93, positive predictive value (PPV) 0.98, and negative predictive value 0.67] and a higher FTI (> 700 gs) warrants transmurality of RF atrial lesions (100% Sp and PPV). Contact force and FTI during RF are correlated with TL. During RF delivery, a target FTI > 392 gs can be used as an endpoint.
引用
收藏
页码:660 / 667
页数:8
相关论文
共 24 条
[1]   Monitoring the local electrogram at the ablation site during radiofrequency application for common atrial flutter [J].
Azegami, K ;
Satake, S ;
Okishige, K ;
Sasano, T ;
Ohira, H ;
Yamashita, K .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1998, 62 (08) :559-564
[2]   2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Patient Selection, Procedural Techniques, Patient Management and Follow-up, Definitions, Endpoints, and Research Trial Design [J].
Calkins, Hugh ;
Kuck, Karl Heinz ;
Cappato, Riccardo ;
Brugada, Josep ;
Camm, A. John ;
Chen, Shih-Ann ;
Crijns, Harry J. G. ;
Damiano, Ralph J., Jr. ;
Davies, D. Wyn ;
DiMarco, John ;
Edgerton, James ;
Ellenbogen, Kenneth ;
Ezekowitz, Michael D. ;
Haines, David E. ;
Haissaguerre, Michel ;
Hindricks, Gerhard ;
Iesaka, Yoshito ;
Jackman, Warren ;
Jalife, Jose ;
Jais, Pierre ;
Kalman, Jonathan ;
Keane, David ;
Kim, Young-Hoon ;
Kirchhof, Paulus ;
Klein, George ;
Kottkamp, Hans ;
Kumagai, Koichiro ;
Lindsay, Bruce D. ;
Mansour, Moussa ;
Marchlinski, Francis E. ;
McCarthy, Patrick M. ;
Mont, J. Lluis ;
Morady, Fred ;
Nademanee, Koonlawee ;
Nakagawa, Hiroshi ;
Natale, Andrea ;
Nattel, Stanley ;
Packer, Douglas L. ;
Pappone, Carlo ;
Prystowsky, Eric ;
Raviele, Antonio ;
Reddy, Vivek ;
Ruskin, Jeremy N. ;
Shemin, Richard J. ;
Tsao, Hsuan-Ming ;
Wilber, David ;
Ad, Niv ;
Cummings, Jennifer ;
Gillinov, A. Mark ;
Heidbuchel, Hein .
EUROPACE, 2012, 14 (04) :528-606
[3]   The durability of pulmonary vein isolation using the visually guided laser balloon catheter: Multicenter results of pulmonary vein remapping studies [J].
Dukkipati, Srinivas R. ;
Neuzil, Petr ;
Kautzner, Josef ;
Petru, Jan ;
Wichterle, Dan ;
Skoda, Jan ;
Cihak, Robert ;
Peichl, Petr ;
Dello Russo, Antonio ;
Pelargonio, Gemma ;
Tondo, Claudio ;
Natale, Andrea ;
Reddy, Vivek Y. .
HEART RHYTHM, 2012, 9 (06) :919-925
[4]   Atrial linear ablations in pigs - Chronic effects on atrial electrophysiology and pathology [J].
Gepstein, L ;
Hayam, G ;
Shpun, S ;
Cohen, D ;
Ben-Haim, SA .
CIRCULATION, 1999, 100 (04) :419-426
[5]  
Karim R, 2011, MAGNETIC RESONANCE I, pAB15
[6]  
Kautzner J, 2012, HEART RHYTHM, V9, pS28
[7]   Late recurrent arrhythmias after ablation of atrial fibrillation: Incidence, mechanisms, and treatment [J].
Kobza, R ;
Hindricks, G ;
Tanner, H ;
Schirdewahn, P ;
Dorszewski, A ;
Piorkowski, C ;
Gerds-Li, JH ;
Kottkamp, H .
HEART RHYTHM, 2004, 1 (06) :676-683
[8]   A novel radiofrequency ablation catheter using contact force sensing: Toccata study [J].
Kuck, Karl-Heinz ;
Reddy, Vivek Y. ;
Schmidt, Boris ;
Natale, Andrea ;
Neuzil, Petr ;
Saoudi, Nadir ;
Kautzner, Josef ;
Herrera, Claudia ;
Hindricks, Gerhard ;
Jais, Pierre ;
Nakagawa, Hiroshi ;
Lambert, Hendrik ;
Shah, Dipen C. .
HEART RHYTHM, 2012, 9 (01) :18-23
[9]   Clinical Impact of an Open-Irrigated Radiofrequency Catheter with Direct Force Measurement on Atrial Fibrillation Ablation [J].
Martinek, Martin ;
Lemes, Christine ;
Sigmund, Elisabeth ;
Derndorfer, Michael ;
Aichinger, Josef ;
Winter, Siegmund ;
Nesser, Hans-Joachim ;
Puererfellner, Helmut .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (11) :1312-1318
[10]  
Nakagawa H., 2012, HEART RHYTHM, V9, pS210