Intense Pulsed Light for Skin Rejuvenation, Hair Removal, and Vascular Lesions A Patient Satisfaction Study and Review of the Literature

被引:15
作者
Fodor, Lucian [1 ,2 ,3 ]
Carmi, Narit [4 ]
Fodor, Adriana [5 ]
Ramon, Ytzhack [1 ,2 ]
Ullmann, Yehuda [1 ,2 ]
机构
[1] Technion Israel Inst Technol, Dept Plast & Reconstruct Surg, Haifa, Israel
[2] Technion Israel Inst Technol, Fac Med, Haifa, Israel
[3] Emergency Dist Hosp, Surg Clin 1, Dept Plast Surg, Cluj Napoca, Romania
[4] Tel Hai Acad Coll, Dept Biotechnol, Upper Galilee, Israel
[5] Technion Israel Inst Technol, Inst Endocrinol & Metab, Haifa, Israel
关键词
IPL; rejuvenation; hair removal; vascular lesions; satisfaction; PHOTODAMAGED SKIN; YAG LASER; FACE; PHOTOREJUVENATION; EPILIGHT;
D O I
10.1097/SAP.0b013e3181856d6a
中图分类号
R61 [外科手术学];
学科分类号
摘要
There are very few studies in the English literature that evaluate the patient satisfaction after treatment using intense pulsed light (IPL) and there is no reported study comparing the results of the three major IPL applications: rejuvenation, hair removal, and treatment of small vascular lesions. This study was designed to compare results after IPL treatment for skin rejuvenation, hair removal, and vascular lesions. Three groups of 30 consecutive patients having skin rejuvenation, hair removal, and small vascular lesions were selected and treated with the same IPL system. The evaluation was performed 1 year after the last treatment for the following parameters: age, sex, skin type, satisfaction, willingness to continue the treatment, willingness to recommend the treatment, and complications. Most of the minor complications occurred in the rejuvenation group (86.6'%). No complications were recorded for 67% of patients having hair removal and for 75% having vascular lesion treatment. There was no significant difference in the level of satisfaction between the 3 groups (Kruskal Wallis test; P = 0.257). No difference regarding satisfaction was recorded in this study, but complications were more frequently encountered after rejuvenation. The findings of this study are useful when discussing IPL treatments with patients considering IPL procedures.
引用
收藏
页码:345 / 349
页数:5
相关论文
共 45 条
[1]   Treatment of leg telangiectasias using a long-pulse frequency-doubled Neodymium:YAG laser at 532 nm [J].
Adrian, RM .
DERMATOLOGIC SURGERY, 1998, 24 (01) :19-23
[2]   SELECTIVE PHOTOTHERMOLYSIS - PRECISE MICROSURGERY BY SELECTIVE ABSORPTION OF PULSED RADIATION [J].
ANDERSON, RR ;
PARRISH, JA .
SCIENCE, 1983, 220 (4596) :524-527
[3]  
Angermeier M C, 1999, J Cutan Laser Ther, V1, P95, DOI 10.1080/14628839950516922
[4]   Treatment of spider veins with the 595 nm pulsed-dye laser [J].
Bernstein, EF ;
Lee, J ;
Lowery, J ;
Brown, DB ;
Geronemus, R ;
Lask, G ;
Hsia, J .
JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1998, 39 (05) :746-750
[5]   Noninvasive rejuvenation of photodamaged skin using serial, full-face intense pulsed light treatments [J].
Bitter, PH .
DERMATOLOGIC SURGERY, 2000, 26 (09) :835-842
[6]  
Bjerring P, 2000, J Cutan Laser Ther, V2, P63, DOI 10.1080/14628830050516470
[7]  
Bjerring P, 2000, J Cutan Laser Ther, V2, P177, DOI 10.1080/146288300750163745
[8]  
Dierickx C., 2000, DERMATOL THER, V13, P80, DOI [10.1046/j.1529-8019.2000.00009.x, DOI 10.1046/J.1529-8019.2000.00009.X]
[9]   THERMAL RELAXATION OF PORT-WINE STAIN VESSELS PROBED IN-VIVO - THE NEED FOR 1-10 MILLISECOND LASER-PULSE TREATMENT [J].
DIERICKX, CC ;
CASPARIAN, JM ;
VENUGOPALAN, V ;
FARINELLI, WA ;
ANDERSON, RR .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1995, 105 (05) :709-714
[10]  