Measuring changes in the optic nerve sheath diameter in patients with idiopathic normal-pressure hydrocephalus: a useful diagnostic supplement to spinal tap tests

被引:30
作者
Ertl, M. [1 ]
Aigner, R. [1 ]
Krost, M. [1 ]
Karnasova, Z. [1 ]
Mueller, K. [2 ]
Naumann, M. [1 ]
Schlachetzki, F. [3 ]
机构
[1] Klinikum Augsburg, Clin Neurol & Neurophysiol, Stenglinstr 2, D-86156 Augsburg, Germany
[2] Univ Med Ctr Regensburg, Ctr Clin Studies, Regensburg, Germany
[3] Univ Regensburg, Dept Neurol Clin Neurol Rehabil 2, Regensburg, Germany
关键词
normal-pressure hydrocephalus; ocular ultrasound; optic nerve sheath diameter; spinal tap test; INTRACRANIAL-PRESSURE; BRAIN-INJURY; SONOGRAPHY; MANAGEMENT; ULTRASOUND;
D O I
10.1111/ene.13225
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: and purposeCerebrospinal fluid (CSF) removal improves clinical symptoms of many patients with idiopathic normal-pressure hydrocephalus (iNPH). The aim of this study was to investigate the correlation of changes in the optic nerve sheath diameter (ONSD) with patient responses to CSF removal. Methods: Transorbital ultrasonography was performed to obtain ONSD measurements in 31 patients with iNPH before and after lumbar puncture. Measurements were obtained while patients were supine and upright. Changes in the ONSD between supine and upright positions [ONSD variability (ONSD-V)] were assessed and compared with those in 60 healthy volunteers. ONSD-V was correlated with relative changes in a validated iNPH severity (Boon) score. Results: Mean pre-puncture ONSD-V was significantly lower in healthy volunteers and patients with no response to CSF removal (Fisher test) [0.05 +/- 0.14 mm (SD)] than in responsive patients [0.37 +/- 0.20 mm (SD), P < 0.001]. ONSD-V predicted response to the spinal tap test (odds ratio, 0.30; 95% confidence interval, 0.12-0.75 mm, P = 0.011). The higher the ONSD-V, the better the therapeutic effect (chi(2) = 14.980, P < 0.001). The post-spinal tap test ONSD-V correlated significantly with clinical severity in the motor portion of the Boon score [0.16 +/- 0.23 mm (SD), P = 0.003]. Conclusions: The ONSD-V before and after spinal tap test correlated well with the clinical effects of CSF removal. Transorbital ultrasonography seems to be a reliable, safe add-on to the Fisher test and may support selection of patients for shunt intervention.
引用
收藏
页码:461 / 467
页数:7
相关论文
共 24 条
[1]   Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging [J].
Baeuerle, Jochen ;
Schuchardt, Florian ;
Schroeder, Laure ;
Egger, Karl ;
Weigel, Matthias ;
Harloff, Andreas .
BMC NEUROLOGY, 2013, 13
[2]   Sonographic assessment of the optic nerve sheath in idiopathic intracranial hypertension [J].
Baeuerle, Jochen ;
Nedelmann, Max .
JOURNAL OF NEUROLOGY, 2011, 258 (11) :2014-2019
[3]   Dutch normal-pressure hydrocephalus study: randomized comparison of low- and medium-pressure shunts [J].
Boon, AJW ;
Tans, JTJ ;
Delwel, EJ ;
Egeler-Peerdeman, SM ;
Hanlo, PW ;
Wurzer, HAL ;
Avezaat, CJJ ;
de Jong, DA ;
Gooskens, RHJM ;
Hermans, J .
JOURNAL OF NEUROSURGERY, 1998, 88 (03) :490-495
[4]  
BRADLEY WG, 1991, AM J NEURORADIOL, V12, P31
[5]   Dutch normal pressure hydrocephalus study: Baseline characteristics with emphasis on clinical findings [J].
Doon, AJW ;
Tans, JTJ ;
Delwel, EJ ;
EgelerPeerdeman, SM ;
Hanlo, PW ;
Wurzer, JAL ;
Hermans, J .
EUROPEAN JOURNAL OF NEUROLOGY, 1997, 4 (01) :39-47
[6]   Ocular Color-Coded Sonography - A Promising Tool for Neurologists and Intensive Care Physicians [J].
Ertl, M. ;
Barinka, F. ;
Torka, E. ;
Altmann, M. ;
Pfister, K. ;
Helbig, H. ;
Bogdahn, U. ;
Gamulescu, M. A. ;
Schlachetzki, F. .
ULTRASCHALL IN DER MEDIZIN, 2014, 35 (05) :422-431
[7]   Optic Nerve Sheath Diameter Measurement to Identify High-Risk Patients for Spinal Ischemia after Endovascular Thoracoabdominal Aortic Aneurysm Repair [J].
Ertl, Michael ;
Schierling, Wilma ;
Kasprzak, Piotr ;
Schoemig, Beate ;
Brueckl, Corinna ;
Schlachetzki, Felix ;
Pfister, Karin .
JOURNAL OF NEUROIMAGING, 2015, 25 (06) :910-915
[8]   Management of spontaneous intracranial hypotension - Transorbital ultrasound as discriminator [J].
Fichtner, Jens ;
Ulrich, Christian T. ;
Fung, Christian ;
Knueppel, Christin ;
Veitweber, Martina ;
Jilch, Astrid ;
Schucht, Philippe ;
Ertl, Michael ;
Schoemig, Beate ;
Gralla, Jan ;
Z'Graggen, Werner J. ;
Bernasconi, Corrado ;
Mattle, Heinrich P. ;
Schlachetzki, Felix ;
Raabe, Andreas ;
Beck, Juergen .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2016, 87 (06) :650-655
[9]   Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury [J].
Geeraerts, Thomas ;
Launey, Yoann ;
Martin, Laurent ;
Pottecher, Julien ;
Vigue, Bernard ;
Duranteau, Jacques ;
Benhamou, Dan .
INTENSIVE CARE MEDICINE, 2007, 33 (10) :1704-1711
[10]   Ultrasound assessment of optic nerve sheath diameter in healthy volunteers [J].
Goeres, Patrick ;
Zeiler, Frederick A. ;
Unger, Bertram ;
Karakitsos, Dimitrios ;
Gillman, Lawrence M. .
JOURNAL OF CRITICAL CARE, 2016, 31 (01) :168-171