Slurry sampling for hydride generation atomic absorption spectrometric determination of arsenic in cigarette tobaccos

被引:33
作者
Mierzwa, J
Adeloju, SB
Dhindsa, HS
机构
[1] UNIV WESTERN SYDNEY NEPEAN,CTR ELECTROCHEM RES & ANALYT TECHNOL,KINGSWOOD,NSW 2747,AUSTRALIA
[2] UNIV WESTERN SYDNEY NEPEAN,DEPT CHEM,KINGSWOOD,NSW 2747,AUSTRALIA
[3] UNIV NEW ENGLAND,DEPT CHEM,ARMIDALE,NSW 2351,AUSTRALIA
关键词
arsenic; atomic absorption spectrometry; hydride generation; slurried sample; cigarette tobacco;
D O I
10.1039/a608246g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a slurry sampling hydride generation atomic absorption spectrometric (HGAAS) method for the determination of arsenic in cigarette tobacco samples is described, The method is relatively simple and has been shown to give values of total arsenic close to those obtained using methods requiring total dissolution and decomposition of all vegetable matter before analysis, Pre-treatment of samples slurried in nitric acid by ultrasonication permitted the extraction of about 90% of the total arsenic from tobacco samples. Further improvement in the recovery efficiency (up to 93-94%) was accomplished by the use of an additional step of short microwave-accelerated treatment. L-Cysteine was used as a pre-reduction agent, The accuracy and precision of the slurry sampling HGAAS method were studied using the certified reference material (CRM) CTA-OTL-1 Oriental Tobacco Leaves, Under the optimum conditions, as little as 2.6 ng of arsenic can be detected. The relative standard deviation of the overall procedure was calculated to be below 7.6% at arsenic concentration levels of 0.5-0.9 mg kg(-1) and the analytical results obtained for the CRM agreed with the certified value, The main factors that influenced the reliability of the method were sample homogeneity, particle size and slurry concentration.
引用
收藏
页码:539 / 542
页数:4
相关论文
共 21 条
[1]  
AHMED S, 1979, J RADIOANAL CHEM, V54, P331
[2]   METHOD FOR THE SIMULTANEOUS DETERMINATION OF ARSENIC, ALUMINUM, IRON, ZINC, CHROMIUM AND COPPER IN PLANT-TISSUE WITHOUT THE USE OF PERCHLORIC-ACID [J].
ARAFAT, NM ;
GLOOSCHENKO, WA .
ANALYST, 1981, 106 (1268) :1174-1178
[3]   INTERFERENCE REDUCTION BY L-CYSTINE IN THE DETERMINATION OF ARSENIC BY HYDRIDE GENERATION [J].
BOAMPONG, C ;
BRINDLE, ID ;
LE, XC ;
PIDWERBESKY, L ;
PONZONI, CMC .
ANALYTICAL CHEMISTRY, 1988, 60 (11) :1185-1188
[4]  
BRINDLE ID, 1989, ANAL CHEM, V1, P1175
[5]  
CHEN H, 1992, ANAL CHEM, V64, P687
[6]   DIRECT SOLID VS SLURRY ANALYSIS OF TOBACCO-LEAVES FOR SOME TRACE-METALS BY GRAPHITE-FURNACE AAS - A COMPARATIVE-STUDY [J].
DOBROWOLSKI, R ;
MIERZWA, J .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 344 (7-8) :340-344
[7]  
DUPIRE S, 1980, ANALUSIS, V8, P153
[8]  
GARCIA IL, 1993, ATOM SPECTROSC, V14, P144
[9]   ARSENIC DETERMINATION IN TOBACCO BY ATOMIC-ABSORPTION SPECTROMETRY [J].
GRIFFIN, HR ;
HOCKING, MB ;
LOWERY, DG .
ANALYTICAL CHEMISTRY, 1975, 47 (02) :229-233
[10]   DETERMINATION OF ARSENIC IN SOLID SAMPLES BY COLD ACID SOLUBILIZATION - HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY [J].
HASWELL, SJ ;
MENDHAM, J ;
BUTLER, MJ ;
SMITH, DC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (05) :731-734