Subclavian steal syndrome: Can the blood pressure difference between arms predict the severity of steal?

被引:42
作者
Tan, TY
Schminke, U
Lien, LM
Tegeler, CH
机构
[1] Chang Gung Mem Hosp, Dept Neurol, Kaohsiung, Taiwan
[2] Wake Forest Univ, Dept Neurol, Winston Salem, NC 27109 USA
[3] Ernst Moritz Arndt Univ Greifswald, Dept Neurol, Greifswald, Germany
[4] Shin Kong WHS Mem Hosp, Dept Neurol, Taipei, Taiwan
关键词
subclavian steal syndrome; blood pressure difference; vertebral artery waveform;
D O I
10.1111/j.1552-6569.2002.tb00109.x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose. A side-to-side difference in systolic brachial arterial blood pressure is a common finding in subclavian artery stenosis and is frequently used as a screening tool for subclavian steal syndrome (SSS), It was the goal of this retrospective study to investigate the relationship between different vertebral artery waveform types and the side-to-side difference in systolic blood pressure in patients with sonographically proven SSS. Methods, The records of 1860 patients from the Neuroultrasound Laboratory between January 2000 and December 2000 were screened for the diagnosis of SSS in the final ultrasound report, In all patients, bilateral brachial arterial blood pressure was measured in a sitting position prior to the ultrasound examination, Vertebral artery waveforms were classified as (1) systolic deceleration, (2) alternating flow, and (3) complete reversal at rest, Blood pressure difference as calculated by normal-side blood pressure minus lesion-side blood pressure was compared with the 3 Doppler waveform types. Results. SSS was found in 51 of 1860 (2.7%) ultrasonography studies of 49 patients (17 men, 32 women; mean age 65.3+/-10.5 years). Two patients (4%) had bilateral SSS. In 3 patients (6%), SSS was related to an innominate artery stenosis, Waveform analysis showed a completely reversed flow in 16 (31%), an alternating flow in 24 (47%), and a systolic deceleration in 11 (22%) cases. Systolic blood pressure difference was significantly higher in the complete reversal and alternating groups than in the systolic deceleration group (P<.001). Conclusion, Brachial systolic blood pressure difference is related to the severity of SSS and can be used as a screening tool for SSS. However, it performed better in severe steal than milder steal phenomena.
引用
收藏
页码:131 / 135
页数:5
相关论文
共 23 条
[1]   ULTRASONIC DUPLEX SCANNING IN ATHEROSCLEROTIC DISEASE OF THE INNOMINATE, SUBCLAVIAN AND VERTEBRAL ARTERIES - A COMPARATIVE-STUDY WITH ANGIOGRAPHY [J].
ACKERSTAFF, RGA ;
HOENEVELD, H ;
SLOWIKOWSKI, JM ;
MOLL, FL ;
EIKELBOOM, BC ;
LUDWIG, JW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1984, 10 (04) :409-418
[2]  
BARTELS E, 1999, COLOR CODED DUPLEX U, P157
[3]  
BORNSTEIN NM, 1988, J CARDIOVASC ULTRAS, V7, P15
[4]  
BORNSTEIN NM, 1986, LANCET, V2, P303
[5]  
BRANCHEREAU A, 1991, J CARDIOVASC SURG, V32, P604
[6]  
CONTORNI L, 1960, Minerva Chir, V15, P268
[7]   JOINT STUDY OF EXTRACRANIAL ARTERIAL OCCLUSION .7. SUBCLAVIAN STEAL - REVIEW OF 168 CASES [J].
FIELDS, WS ;
LEMAK, NA .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1972, 222 (09) :1139-&
[8]   THE SUBCLAVIAN STEAL PHENOMENON - A COMMON VASCULAR DISORDER WITH RARE NEUROLOGIC DEFICITS [J].
HENNERICI, M ;
KLEMM, C ;
RAUTENBERG, W .
NEUROLOGY, 1988, 38 (05) :669-673
[9]  
Herring M, 1974, J Indiana State Med Assoc, V67, P641
[10]  
HEWITT RL, 1970, ARCH SURG-CHICAGO, V101, P155