Validation of a multiplex electrochemiluminescent immunoassay platform in human and mouse samples

被引:51
作者
Bastarache, J. A. [1 ]
Koyama, T. [2 ]
Wickersham, N. E. [1 ]
Ware, L. B. [1 ]
机构
[1] Vanderbilt Univ, Sch Med, Div Allergy Pulm & Crit Care Med, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Sch Med, Dept Biostat, Nashville, TN 37232 USA
关键词
Immunoassay; ELISA; Biomarkers; Plasma; Bronchoalveolar lavage; BIOMARKERS; SERUM; PREDICT; PLASMA; ASSAYS; INJURY;
D O I
10.1016/j.jim.2014.04.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Despite the widespread use of multiplex immunoassays, there are very few scientific reports that test the accuracy and reliability of a platform prior to publication of experimental data. Our laboratory has previously demonstrated the need for new assay platform validation prior to use of biologic samples from large studies in order to optimize sample handling and assay performance. Methods: In this study, our goal was to test the accuracy and reproducibility of an electrochemiluminescent multiplex immunoassay platform (Mesa Scale Discovery, MSD (R)) and compare this platform to validated, singleplex immunoassays (R&D Systems (R)) using actual study subject (human plasma and mouse bronchoalveolar lavage fluid (BAL) and plasma) samples. Results: We found that the MSD platform performed well on intra- and inter-assay comparisons, spike and recovery and cross-platform comparisons. The mean intra-assay CV% and range for MSD were 3.49 (0.0-10.4) for IL-6 and 2.04 (0.1-7.9) for IL-8. The correlation between values for identical samples measured on both MSD and R&D was R = 0.97 for both analytes. The mouse MSD assay had a broader range of CV% with means ranging from 9.5 to 28.5 depending on the analyte. The range of mean CV% was similar for single plex ELISAs at 43-23.7 depending on the analyte. Regardless of species or sample type, CV% was more variable at lower protein concentrations. Conclusions: In conclusion, we validated a multiplex electrochemiluminescent assay system and found that it has superior test characteristics in human plasma compared to mouse BALF and plasma. Both human and MSD assays compared favorably to well-validated singleplex ELISAs. Published by Elsevier B.V.
引用
收藏
页码:13 / 23
页数:11
相关论文
共 33 条
[1]   Profiling of Sputum Inflammatory Mediators in Asthma and Chronic Obstructive Pulmonary Disease [J].
Bafadhel, M. ;
McCormick, M. ;
Saha, S. ;
McKenna, S. ;
Shelley, M. ;
Hargadon, B. ;
Mistry, V. ;
Reid, C. ;
Parker, D. ;
Dodson, P. ;
Jenkins, M. ;
Lloyd, A. ;
Rugman, P. ;
Newbold, Paul ;
Brightling, C. E. .
RESPIRATION, 2012, 83 (01) :36-44
[2]   Low levels of tissue factor lead to alveolar haemorrhage, potentiating murine acute lung injury and oxidative stress [J].
Bastarache, Julie A. ;
Sebag, Sara C. ;
Clune, Jennifer K. ;
Grove, Brandon S. ;
Lawson, William E. ;
Janz, David R. ;
Roberts, L. Jackson, II ;
Dworski, Ryszard ;
Mackman, Nigel ;
Ware, Lorraine B. .
THORAX, 2012, 67 (12) :1032-1039
[3]   Accuracy and reproducibility of a multiplex immunoassay platform: A validation study [J].
Bastarache, Julie A. ;
Koyama, Tatsuki ;
Wickersham, Nancy E. ;
Mitchell, Daphne B. ;
Mernaugh, Ray L. ;
Ware, Lorraine B. .
JOURNAL OF IMMUNOLOGICAL METHODS, 2011, 367 (1-2) :33-39
[4]   Performance evaluation of a multiplex assay for future use in biomarker discovery efforts to predict body composition [J].
Bea, Jennifer W. ;
Wright, Nicole C. ;
Thompson, Patricia ;
Hu, Chengcheng ;
Guerra, Stefano ;
Chen, Zhao .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (05) :817-824
[5]   A condensed performance-validation strategy for multiplex detection kits used in studies of human clinical samples [J].
Belabani, Chahrazed ;
Rajasekharan, Sathyanath ;
Poupon, Viviane ;
Johnson, Trina ;
Bar-Or, Amit .
JOURNAL OF IMMUNOLOGICAL METHODS, 2013, 387 (1-2) :1-10
[6]   Multisite Comparison of High-Sensitivity Multiplex Cytokine Assays [J].
Breen, Elizabeth Crabb ;
Reynolds, Sandra M. ;
Cox, Christopher ;
Jacobson, Lisa P. ;
Magpantay, Larry ;
Mulder, Candice B. ;
Dibben, Oliver ;
Margolick, Joseph B. ;
Bream, Jay H. ;
Sambrano, Elise ;
Martinez-Maza, Otoniel ;
Sinclair, Elizabeth ;
Borrow, Persephone ;
Landay, Alan L. ;
Rinaldo, Charles R. ;
Norris, Philip J. .
CLINICAL AND VACCINE IMMUNOLOGY, 2011, 18 (08) :1229-1242
[7]   Soluble intercellular adhesion molecule-1 and clinical outcomes in patients with acute lung injury [J].
Calfee, Carolyn S. ;
Eisner, Mark D. ;
Parsons, Polly E. ;
Thompson, B. Taylor ;
Conner, Edward R., Jr. ;
Matthay, Michael A. ;
Ware, Lorraine B. .
INTENSIVE CARE MEDICINE, 2009, 35 (02) :248-257
[8]   Novel multiplex technology for diagnostic characterization of rheumatoid arthritis [J].
Chandra, Piyanka E. ;
Sokolove, Jeremy ;
Hipp, Berthold G. ;
Lindstrom, Tamsin M. ;
Elder, James T. ;
Reveille, John D. ;
Eberl, Heike ;
Klause, Ursula ;
Robinson, William H. .
ARTHRITIS RESEARCH & THERAPY, 2011, 13 (03)
[9]   Validation and comparison of two multiplex technologies, Luminex® and Mesoscale Discovery, for human cytokine profiling [J].
Chowdhury, Ferdousi ;
Williams, Anthony ;
Johnson, Peter .
JOURNAL OF IMMUNOLOGICAL METHODS, 2009, 340 (01) :55-64
[10]   Plasma Levels of Receptor for Advanced Glycation End Products, Blood Transfusion, and Risk of Primary Graft Dysfunction [J].
Christie, Jason D. ;
Shah, Chirag V. ;
Kawut, Steven M. ;
Mangalmurti, Nilam ;
Lederer, David J. ;
Sonett, Joshua R. ;
Ahya, Vivek N. ;
Palmer, Scott M. ;
Wille, Keith ;
Lama, Vibha ;
Shah, Pali D. ;
Shah, Ashish ;
Weinacker, Ann ;
Deutschman, Clifford S. ;
Kohl, Benjamin A. ;
Demissie, Ejigayehu ;
Bellamy, Scarlett ;
Ware, Lorraine B. .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 180 (10) :1010-1015