Relationship between supernormal sectors of retinal nerve fibre layer and axial length in normal eyes

被引:31
|
作者
Yamashita, Takehiro [1 ]
Kii, Yuya [1 ]
Tanaka, Minoru [1 ]
Yoshinaga, Wakako [1 ]
Yamashita, Toshifumi [1 ]
Nakao, Kumiko [1 ]
Sakamoto, Taiji [1 ]
机构
[1] Kagoshima Univ, Grad Sch Med & Dent Sci, Dept Ophthalmol, Kagoshima 890, Japan
关键词
glaucoma; myopia; pseudo-negative; pseudo-positive; retina; RNFL colour code; OPTICAL COHERENCE TOMOGRAPHY; OPEN-ANGLE GLAUCOMA; MYOPIA; THICKNESS; PERFORMANCE; VARIABILITY; PREVALENCE; JAPANESE; DEFECTS; TAJIMI;
D O I
10.1111/aos.12382
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the effect of the axial length on the supernormal and false-positive sectors of the peripapillary retinal nerve fibre layer (RNFL) in healthy eyes using the normative database embedded in a spectral domain optical coherence tomographic (SD-OCT) instrument. Methods: This was a prospective, observational cross -sectional study. The right eyes of 126 healthy young volunteers were studied. The RNFL thickness was measured by SD-OCT in twelve 30-degree sectors (clock hours) around the optic disc. The sectors whose RNFL thickness was <5% probability level were labelled as false-positive sectors. The sectors >95% probability level were labelled as supernormal sectors. The relationships between the axial length and rates of supernormal and false-positive sectors were investigated. Results: A longer axial length was significantly associated with an increase in the rates of supernormal thickness in sector 8 (odds ratio, [OR], 1.494; p = 0.010) and sector 10 (OR, 1.529; p = 0.008). The supernormal sectors were mainly located in the temporal region. A longer axial length was significantly associated with a higher rates of false positives in sector 5 (OR, 1.789; p = 0.017), sector 6 (OR, 2.305; p < 0.001) and sector 12 (OR, 2.277; p = 0.035). Conclusions: The axial length was significantly related to the rates of supernormal and false-positive sectors even in healthy eyes. These findings indicate that the specificity and sensitivity of SD-OCT will be affected especially in eyes with longer axial lengths.
引用
收藏
页码:E481 / E487
页数:7
相关论文
共 50 条
  • [41] The Relationship Between Retinal Nerve Fibre Layer Thickness and Total Retinal Blood Flow in Primary Open Angle Glaucoma
    Flanagan, John G.
    Yusof, Firdaus
    Cheng, Richard
    Tayyari, Faryan
    Espahbodi, Nadia
    Khuu, Lee-Anne
    Buys, Yvonne M.
    Trope, Graham Eric
    Hudson, Christopher
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [42] Correlation between axial length and anterior chamber depth in short eyes, normal eyes, and long eyes
    El-Ghazawy, Rafik M. F.
    El-Awamry, Amr, I
    Zaki, Rania G.
    Aziz, Joseph H. F.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2019, 112 (01) : 30 - 33
  • [43] Investigation of the quantitative relationship between hyperopia and axial length of eyes in children
    Guo, XR
    Ma, LW
    Hou, ZQ
    Xu, GZ
    Zhang, D
    TRANSACTIONS OF THE IX INTERNATIONAL ORTHOPTIC CONGRESS, 1999, : 377 - 377
  • [44] The Relationship Between Axial Length and Choroidal Thickness in Eyes With High Myopia
    Flores-Moreno, Ignacio
    Lugo, Francisco
    Duker, Jay S.
    Ruiz-Moreno, Jose M.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 155 (02) : 314 - 319
  • [45] Nerve fiber analyzer measuring retinal nerve fiber layer thickness in normal and glaucomatous eyes
    李润婷
    余晓临
    杨国华
    王谷珠
    眼科研究, 1999, (04) : 3 - 5+36
  • [46] Peripapillary retinal nerve fibre layer thickness measurement with SD-OCT in normal and glaucomatous eyes:distribution and correlation with age
    George Kampougeris
    Dimitrios Spyropoulos
    Adrianna Mitropoulou
    Aggeliki Zografou
    Pericles Kosmides
    International Journal of Ophthalmology, 2013, (05) : 662 - 665
  • [47] Reproducibility of peripapillary retinal nerve fibre layer thickness measurements with spectral domain optical coherence tomography in normal and glaucomatous eyes
    Mansoori, Tarannum
    Viswanath, Kalluri
    Balakrishna, Nagalla
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (05) : 685 - 688
  • [48] The structure-function relationship between multifocal pupil perimetry and retinal nerve fibre layer in glaucoma
    Carle, Corinne F.
    Chain, Allan Y. H.
    Kolic, Maria
    Maddess, Ted
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [49] The relationship between Rarebit perimetry and OCT-derived retinal nerve fibre layer thickness in glaucoma
    Katsanos, Andreas
    Labiris, Georgios
    Fanariotis, Michael
    Tsirouki, Theodora
    Chatzoulis, Dimitrios
    ACTA OPHTHALMOLOGICA, 2008, 86 (08) : 871 - 876
  • [50] Investigating the relationship between retinal nerve fibre layer thickness and intraocular pressure in an aging twin population
    Wong, Claire Lixian
    Simcoe, Mark James
    Kozareva, Diana
    Hammond, Christopher J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)