Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants

被引:55
作者
Kahraman, S. [2 ]
Bal, B. T. [3 ]
Asar, N. V. [4 ]
Turkyilmaz, I. [4 ]
Tozum, T. F. [1 ]
机构
[1] Univ Hacettepe, Fac Dent, Dept Periodontol, TR-06100 Ankara, Turkey
[2] Gazi Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Ankara, Turkey
[3] Gazi Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
[4] Univ Texas Hlth Sci Ctr San Antonio, Sch Dent, Dept Prosthodont, San Antonio, TX 78229 USA
关键词
dental implants; insertion torque; stability; resonance frequency analysis; NITRIC-OXIDE METABOLISM; FOLLOW-UP; COMPUTERIZED-TOMOGRAPHY; MANDIBULAR OVERDENTURES; CUTTING TORQUE; IN-VITRO; BONE; VALUES; PROTOCOLS; DEVICES;
D O I
10.1111/j.1365-2842.2009.01990.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
P>Resonance frequency (RF) analysis is a non-invasive, objective and sensitive technique developed for implantology where it measures the stability of the implant in osteotomy site. Although many studies were performed by the previous electronic version of RF analyzer, a very limited number of studies were carried out with the new magnetic wireless version. The aim of the study was to evaluate the relation between insertion torques, primary and secondary stability of self-tapping tapered implant systems. Thirteen subjects were treated with 42 endosseous implants using two-stage surgical procedure. The maximal insertion torque values were recorded prior to RF analysis during surgery. Six months after surgery, the secondary stability values were measured by the RF analysis. The average maximal insertion torque and primary and secondary magnetic RF values were 33 +/- 11 N cm and 66 +/- 12 ISQ and 71 center dot 9 +/- 6 ISQ for 42 implants respectively. The correlation between insertion torque and RF values were indicated to be statistically significant (P < 0 center dot 01). Significantly higher maximal insertion torque, and primary and secondary magnetic RF values were achieved in mandibular sites compared with maxillary areas (P < 0 center dot 01). No significant differences were measured for all parameters when both systems were compared with each other (P > 0 center dot 05). There was a strong correlation between the insertion torque, primary and secondary magnetic RF values of self-tapping tapered endosseous implant used. Further studies are needed to understand the impact of the wireless magnetic RF analysis technique in clinics.
引用
收藏
页码:755 / 761
页数:7
相关论文
共 37 条
[1]  
Al-Nawas B, 2006, INT J ORAL MAX IMPL, V21, P726
[2]  
Albrektsson T, 1998, INT J PROSTHODONT, V11, P517
[3]   A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment [J].
Alsaadi, Ghada ;
Quirynen, Marc ;
Michiels, Katleen ;
Jacobs, Reinhilde ;
van Steenberghe, Daniel .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (04) :359-366
[4]   A comparison of endosseous dental implant surfaces [J].
Cochran, DL .
JOURNAL OF PERIODONTOLOGY, 1999, 70 (12) :1523-1539
[5]  
da Cunha HA, 2004, INT J ORAL MAX IMPL, V19, P578
[6]  
Degidi M, 2006, INT J ORAL MAX IMPL, V21, P763
[7]   A retrospective analysis of factors associated with multiple implant failures in maxillae [J].
Ekfeldt, A ;
Christiansson, U ;
Eriksson, T ;
Lindén, U ;
Lundqvist, S ;
Rundcrantz, T ;
Johansson, LÅ ;
Nilner, K ;
Billström, C .
CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (05) :462-467
[8]  
ESPOSITO M, 2007, COCHRANE DB SYST REV, V18
[9]  
Friberg B, 1999, INT J ORAL MAX SURG, V28, P297
[10]   A conceptual framework for understanding outcomes of oral implant therapy [J].
Guckes, AD ;
Scurria, MS ;
Shugars, DA .
JOURNAL OF PROSTHETIC DENTISTRY, 1996, 75 (06) :633-639