The usefulness of re-attachability of anti-adhesive cross-linked gelatin film and the required physical and biological properties

被引:1
作者
Horii, Tsunehito [1 ,2 ]
Tsujimoto, Hiroyuki [1 ,2 ]
Kageyama, Susumu [1 ]
Yoshida, Tetsuya [1 ]
Kobayashi, Kenichi [1 ]
Takamori, Hideki [2 ]
Minato, Hiroshi [3 ]
Ueda, Jo [4 ]
Hagiwara, Akeo [1 ,2 ]
Ichikawa, Hiroshi [2 ]
Kawauchi, Akihiro [1 ]
机构
[1] Shiga Univ Med Sci, Dept Urol, Otsu, Shiga 5202192, Japan
[2] Doshisha Univ, Dept Life & Med Sci, Div Med Life Syst, Kyoto, Japan
[3] Yawata Cent Hosp, Dept Surg, Kyoto, Japan
[4] Ueda Clin, Dept Gastroenterol, Akita, Japan
基金
日本学术振兴会;
关键词
Anti-adhesion; re-attachability; gelatin film; thermally cross-linked; tissue injury; ADHESION BARRIER; SPRAY-TYPE; PREVENTION; MEMBRANE; SURGERY;
D O I
10.3233/BME-206009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BACKGROUND: To overcome the unfavorable issues associated with conventional anti-adhesive HA/CMC film, we developed an anti-adhesive thermally cross-linked gelatin film. OBJECTIVE: We tried to clarify the re-attachability of the film and the required properties concerning the film thickness, stiffness and anti-adhesion effect. METHODS: To determine the optimal thickness, 5 kinds of the thickness of gelatin film and the conventional film were analyzed by the tensile test, shearing test, buckling test and tissue injury test. Finally, using the optimal film thickness, we tried to clarify the anti-adhesion effect of the reattached film. RESULTS: The tensile and shearing test showed gelatin films >= 30 mu m thick had greater tensile strength and a smaller number of film fractures, than the conventional film. The buckling and tissue injury test showed gelatin films >= 60 mu m thick had higher buckling strength and worse injury scores than the conventional film. The anti-adhesive effect of re-attached gelatin film using optimal thickness (30-40 mu m) found the anti-adhesion score was significantly better than that of the control. CONCLUSIONS: Provided it has an optimal thickness, gelatin film can be reattached with enough physical strength not to tear, safety stiffness not to induce tissue injury, and a sufficient anti-adhesion effect.
引用
收藏
页码:351 / 360
页数:10
相关论文
共 28 条
[1]   Incidence of small-bowel obstruction and adhesiolysis after open colorectal and general surgery [J].
Beck, DE ;
Opelka, FG ;
Bailey, HR ;
Rauh, SM ;
Pashos, CL .
DISEASES OF THE COLON & RECTUM, 1999, 42 (02) :241-248
[2]  
Becker JM, 1996, J AM COLL SURGEONS, V183, P297
[3]   Formation and prevention of postoperative abdominal adhesions [J].
Boland, GM ;
Weigel, RJ .
JOURNAL OF SURGICAL RESEARCH, 2006, 132 (01) :3-12
[4]  
CASPI E, 1979, FERTIL STERIL, V31, P296
[5]   A novel technique to apply a Seprafilm (hyaluronate-carboxymethylcellulose) barrier following laparoscopic surgeries [J].
Chuang, Yi-Chen ;
Fan, Chun-Nan ;
Cho, Fu-Nan ;
Kan, Yuan-Yee ;
Chang, Yu-Hsiang ;
Kang, Hong-Yo .
FERTILITY AND STERILITY, 2008, 90 (05) :1959-1963
[6]  
David EB, 2003, DIS COLON RECTUM, V46, P1310
[7]  
diZerega GS, 1997, EUR J SURG, V163, P10
[8]   Adhesion-related hospital readmissions after abdominal and pelvic surgery: a retrospective cohort study [J].
Ellis, H ;
Moran, BJ ;
Thompson, JN ;
Parker, MC ;
Wilson, MS ;
Menzies, D ;
McGuire, A ;
Lower, AM ;
Hawthorn, RJS ;
O'Brien, F ;
Buchan, S ;
Crowe, AM .
LANCET, 1999, 353 (9163) :1476-1480
[9]  
Genevieve M., J SURG RES, V132, P3
[10]   Physical and biological properties of a novel anti-adhesion material made of thermally cross-linked gelatin film: Investigation of the usefulness as anti-adhesion material [J].
Horii, Tsunehito ;
Tsujimoto, Hiroyuki ;
Miyamoto, Hiroe ;
Yamanaka, Koki ;
Tanaka, Shota ;
Torii, Hiroko ;
Ozamoto, Yuki ;
Takamori, Hideki ;
Nakamachi, Eiji ;
Ikada, Yoshito ;
Hagiwara, Akeo .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2018, 106 (02) :689-696