Three-dimensional transthoracic echocardiographic evaluation of tricuspid regurgitation severity using proximal isovelocity surface area: comparison with volumetric method

被引:5
作者
Chen, Beiqi [1 ,2 ,3 ]
Liu, Yu [1 ,2 ,3 ]
Zuo, Wuxu [1 ,2 ,3 ]
Li, Quan [1 ,2 ,3 ]
Kong, Dehong [1 ,2 ,3 ]
Pan, Cuizhen [1 ,2 ]
Dong, Lili [1 ,2 ,3 ]
Shu, Xianhong [1 ,2 ,3 ]
Ge, Junbo [1 ,2 ,3 ]
机构
[1] Fudan Univ, Zhongshan Hosp, Dept Echocardiog, Shanghai, Peoples R China
[2] Shanghai Inst Med Imaging, Shanghai, Peoples R China
[3] Shanghai Inst Cardiovasc Dis, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Three-dimensional echocardiography; Tricuspid regurgitation; Proximal isovelocity surface area; Effective regurgitant orifice area; COLOR DOPPLER-ECHOCARDIOGRAPHY; NATIVE VALVULAR REGURGITATION; MITRAL-VALVE-PROLAPSE; FLOW CONVERGENCE; EUROPEAN ASSOCIATION; AMERICAN SOCIETY; ORIFICE AREA; RECOMMENDATIONS; QUANTIFICATION; SHAPE;
D O I
10.1186/s12947-020-00225-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The quantification of tricuspid regurgitation(TR) using three-dimensional(3D) proximal isovelocity surface area (PISA) derived effective regurgitant orifice area (EROA) is feasible in functional TR. The aim of our study was to explore the diagnostic accuracy and utility of 3D PISA EROA in a larger population of different etiologies. Methods One hundred and seven patients with confirmed TR underwent 2D and 3D transthoracic echocardiography (TTE). 3D PISA EROA was calculated and EROA derived from 3D regurgitant volume (Rvol) was used as the reference. Results 3D PISA EROA showed better correlation in primary TR than in functional TR(r = 0.897,P < 0.01). 3D PISA EROA differentiated severe TR with comparable accuracy in patients with primary and functional etiology (Z-value 16.506 vs 21.202), but with different cut-offs (0.49cm(2)vs. 0.41 cm(2)). The chi-square value for incorporated clinical symptoms, positive echocardiographic results and 3D PISA EROA to grade severe TR was higher than only included clinical symptoms or incorporated clinical symptoms and positive echocardiographic results (chi-square value 137.233,P < 0.01). Conclusion TR quantification using 3D PISA EROA is feasible and accurate under different etiologies. It has incremental diagnostic value for evaluating severe TR.
引用
收藏
页数:12
相关论文
共 34 条
[1]   Proximal Isovelocity Surface Area by Single-Beat Three-Dimensional Color Doppler Echocardiography Applied for Tricuspid Regurgitation Quantification [J].
Alberto de Agustin, Jose ;
Viliani, Dafne ;
Vieira, Catarina ;
Islas, Fabian ;
Marcos-Alberca, Pedro ;
Juan Gomez de Diego, Jose ;
Javier Nunez-Gil, Ivan ;
Almeria, Carlos ;
Luis Rodrigo, Jose ;
Luaces, Maria ;
Angel Garcia-Fernandez, Miguel ;
Macaya, Carlos ;
Perez de Isla, Leopoldo .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2013, 26 (09) :1063-1072
[2]   Direct Measurement of Proximal Isovelocity Surface Area by Single-Beat Three-Dimensional Color Doppler Echocardiography in Mitral Regurgitation: A Validation Study [J].
Alberto de Agustin, Jose ;
Marcos-Alberca, Pedro ;
Fernandez-Golfin, Covadonga ;
Goncalves, Alexandra ;
Feltes, Gisela ;
Javier Nunez-Gil, Ivan ;
Almeria, Carlos ;
Luis Rodrigo, Jose ;
Perez de Isla, Leopoldo ;
Macaya, Carlos ;
Zamorano, Jose .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (08) :815-823
[3]   Tricuspid regurgitation diagnosis and treatment [J].
Arsalan, Mani ;
Walther, Thomas ;
Smith, Robert L., II ;
Grayburn, Paul A. .
EUROPEAN HEART JOURNAL, 2017, 38 (09) :634-+
[4]   Reproducibility of Proximal Isovelocity Surface Area, Vena Contracta, and Regurgitant Jet Area for Assessment of Mitral Regurgitation Severity [J].
Biner, Simon ;
Rafique, Asim ;
Rafii, Farhad ;
Tolstrup, Kirsten ;
Noorani, Omid ;
Shiota, Takahiro ;
Gurudevan, Swaminatha ;
Siegel, Robert J. .
JACC-CARDIOVASCULAR IMAGING, 2010, 3 (03) :235-243
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Three-Dimensional Color Doppler Echocardiographic Quantification of Tricuspid Regurgitation Orifice Area: Comparison with Conventional Two-Dimensional Measures [J].
Chen, Tien-En ;
Kwon, Susan H. ;
Enriquez-Sarano, Maurice ;
Wong, Benjamin F. ;
Mankad, Sunil V. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2013, 26 (10) :1143-1152
[7]   Quantifying Tricuspid Regurgitation Severity [J].
Dahou, Abdellaziz ;
Ong, Geraldine ;
Hamid, Nadira ;
Avenatti, Eleonora ;
Yao, Jing ;
Hahn, Rebecca T. .
JACC-CARDIOVASCULAR IMAGING, 2019, 12 (03) :560-562
[8]   EFFECTIVE REGURGITANT ORIFICE AREA - A NONINVASIVE DOPPLER DEVELOPMENT OF AN OLD HEMODYNAMIC CONCEPT [J].
ENRIQUEZSARANO, M ;
SEWARD, JB ;
BAILEY, KR ;
TAJIK, AJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (02) :443-451
[9]   CHANGES IN EFFECTIVE REGURGITANT ORIFICE THROUGHOUT SYSTOLE IN PATIENTS WITH MITRAL-VALVE PROLAPSE - A CLINICAL-STUDY USING THE PROXIMAL ISOVELOCITY SURFACE-AREA METHOD [J].
ENRIQUEZSARANO, M ;
SINAK, LJ ;
TAJIK, AJ ;
BAILEY, KR ;
SEWARD, JB .
CIRCULATION, 1995, 92 (10) :2951-2958
[10]   2017 ESC/EACTS Guidelines for the management of valvular heart disease [J].
Falk, Volkmar ;
Baumgartner, Helmut ;
Bax, Jeroen J. ;
De Bonis, Michele ;
Hamm, Christian ;
Holm, Per Johan ;
Iung, Bernard ;
Lancellotti, Patrizio ;
Lansac, Emmanuel ;
Rodriguez Munoz, Daniel ;
Rosenhek, Raphael ;
Sjogren, Johan ;
Tornos Mas, Pilar ;
Vahanian, Alec ;
Walther, Thomas ;
Wendler, Olaf ;
Windecker, Stephan ;
Luis Zamorano, Jose .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 52 (04) :616-664