A newly designed tensile tester for cells and its application to fibroblasts

被引:52
作者
Miyazaki, H [1 ]
Hasegawa, Y [1 ]
Hayashi, K [1 ]
机构
[1] Osaka Univ, Grad Sch Engn Sci, Dept Syst & Human Sci, Div Mech Sci,Biomech Lab, Toyonaka, Osaka 5608531, Japan
关键词
tensile test; cell; fibroblast; mechanical property; cellular mechanics;
D O I
10.1016/S0021-9290(99)00161-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A tensile test system for cells has been designed and applied to fibroblasts from the rabbit patellar tendon. It consists of a thermostatic test chamber, an inverted fluorescence microscope, micromanipulators, a direct drive linear actuator: a cantilever-type load cell, and a video dimension analyzer (VDA). The test chamber and the microscope are mounted on a vibration isolator. A cell floated in Hanks' balanced salt solution of 37 degrees C is gripped with a pair of micropipettes which have very fine tips (outer diameter = 20 similar to 30 mu m, inner diameter = 3 similar to 5 mu m) and are coated with a cell adhesive, Cell-Tak, at their ends. One of the micropipettes is fixed to the load cell; the other one is attached to the linear actuator which is used to stretch the cell. Load applied to the cell is measured with the load cell, while elongation of the cell is determined with the VDA using the images of the ends of the micropipettes as markers. The measurement accuracy of the load cell was +/- 0.05 mu N. All the fibroblasts tested were firmly attached to the micropipettes during tensile testing, and showed local non-uniform deformation. The maximum load and elongation to failure of the cells were 0.9 +/- 0.2 mu N and 86 +/- 24 mu m, respectively. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 24 条
[1]   ROLE OF CORTICAL TENSION IN FIBROBLAST SHAPE AND MOVEMENT [J].
ALBRECHTBUEHLER, G .
CELL MOTILITY AND THE CYTOSKELETON, 1987, 7 (01) :54-67
[2]  
[Anonymous], BIOMECHANICS FUNCTIO
[3]   Mechanical basis of cell shape: Investigations with the scanning acoustic microscope [J].
BereiterHahn, J ;
Karl, I ;
Luers, H ;
Voth, M .
BIOCHEMISTRY AND CELL BIOLOGY, 1995, 73 (7-8) :337-348
[4]   MECHANICAL-STRESS MECHANISMS AND THE CELL - AN ENDOTHELIAL PARADIGM [J].
DAVIES, PF ;
TRIPATHI, SC .
CIRCULATION RESEARCH, 1993, 72 (02) :239-245
[5]   MECHANICAL-PROPERTIES OF MAMMALIAN SINGLE SMOOTH-MUSCLE CELLS .2. EVALUATION OF A MODIFIED TECHNIQUE FOR ATTACHMENT OF CELLS TO THE MEASUREMENT APPARATUS [J].
GLERUM, JJ ;
VANMASTRIGT, R .
JOURNAL OF MUSCLE RESEARCH AND CELL MOTILITY, 1990, 11 (04) :338-343
[6]   MECHANICAL-PROPERTIES OF MAMMALIAN SINGLE SMOOTH-MUSCLE CELLS .1. A LOW-COST LARGE RANGE MICROFORCE TRANSDUCER [J].
GLERUM, JJ ;
VANMASTRIGT, R .
JOURNAL OF MUSCLE RESEARCH AND CELL MOTILITY, 1990, 11 (04) :331-337
[7]   MECHANICAL-PROPERTIES OF MAMMALIAN SINGLE SMOOTH-MUSCLE CELLS .3. PASSIVE PROPERTIES OF PIG DETRUSOR AND HUMAN A TERME UTERUS CELLS [J].
GLERUM, JJ ;
VANMASTRIGT, R ;
VANKOEVERINGE, AJ .
JOURNAL OF MUSCLE RESEARCH AND CELL MOTILITY, 1990, 11 (05) :453-462
[8]  
GOTTLIEB AI, 1991, LAB INVEST, V65, P123
[9]   SERIAL CULTIVATION OF HUMAN DIPLOID CELL STRAINS [J].
HAYFLICK, L ;
MOORHEAD, PS .
EXPERIMENTAL CELL RESEARCH, 1961, 25 (03) :585-+
[10]   VISCOSITY OF PASSIVE HUMAN NEUTROPHILS UNDERGOING SMALL DEFORMATIONS [J].
HOCHMUTH, RM ;
TINGBEALL, HP ;
BEATY, BB ;
NEEDHAM, D ;
TRANSONTAY, R .
BIOPHYSICAL JOURNAL, 1993, 64 (05) :1596-1601