HbA1c and Glucose Management Indicator Discordance: A Real-World Analysis

被引:52
作者
Perlman, Jordan E. [1 ]
Gooley, Theodore A. [2 ]
McNulty, Bridget [3 ]
Meyers, Jedidiah [4 ]
Hirsch, Irl B. [5 ]
机构
[1] Johns Hopkins Univ, Div Endocrinol Diabet & Metab, Baltimore, MD USA
[2] Fred Hutchinson Canc Res Ctr, Div Clin Res, 1124 Columbia St, Seattle, WA 98104 USA
[3] Univ Washington, Dept Psychiat & Behav Med, Seattle, WA 98195 USA
[4] San Antonio Med Ctr SAUSHEC, Dept Anesthesiol, Ft Sam Houston, TX USA
[5] Univ Washington, Dept Med, Div Metab Endocrinol & Nutr, 750 Republican St,Bldg F,3rd Floor, Seattle, WA 98109 USA
关键词
HbA1c; Continuous glucose monitoring; Glucose management indicator; Diabetes management; GLYCEMIC CONTROL; BLOOD-GLUCOSE; ADULTS; TIME;
D O I
10.1089/dia.2020.0501
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: There can be marked discordance between laboratory and estimated (using the glucose management indicator [GMI]) glycated hemoglobin (HbA1c) from continuous glucose monitoring (CGM). This may cause errors in diabetes management. This study evaluates discordance between laboratory and CGM-estimated HbA1c (eA1C). Methods: We performed a retrospective review of patients with diabetes who use CGM. The patients were seen at the University of Washington (UW) Diabetes Care Center from 2012 to 2019. We used UW's Institute of Translational Health Sciences to extract eligible encounters from the electronic medical record. We required that patients use CGM and that HbA1c and sensor data be obtained fewer than 4 weeks apart. There were no exclusion criteria. We calculated HbA1c-GMI discordance for each subject and assessed for any impact of comorbidities. We defined HbA1c-GMI discordance as absolute difference between laboratory and eA1C. Results: This study included 641 separate office encounters. Ninety-one percent of patients had type 1 diabetes. Most patients had diabetes for greater than 20 years. The mean duration of CGM wear was 24.5 +/- 8 days. Only 11% of patients had HbA1c-GMI discordance <0.1%, but 50% and 22% had differences >= 0.5% and >= 1%. There was increased discordance with advanced chronic kidney disease (estimated glomerular filtration rate <60). Discussion: We found substantial discordance between laboratory and eA1C in a real-world setting. Clinicians need be aware that HbA1c may not as accurately reflect mean glucose as previously appreciated.
引用
收藏
页码:253 / 258
页数:6
相关论文
共 18 条
  • [1] REPLACE-BG: A Randomized Trial Comparing Continuous Glucose Monitoring With and Without Routine Blood Glucose Monitoring in Adults With Well-Controlled Type 1 Diabetes
    Aleppo, Grazia
    Ruedy, Katrina J.
    Riddlesworth, Tonya D.
    Kruger, Davida F.
    Peters, Anne L.
    Hirsch, Irl
    Bergenstal, Richard M.
    Toschi, Elena
    Ahmann, Andrew J.
    Shah, Viral N.
    Rickels, Michael R.
    Bode, Bruce W.
    Philis-Tsimikas, Athena
    Pop-Busui, Rodica
    Rodriguez, Henry
    Eyth, Emily
    Bhargava, Anuj
    Kollman, Craig
    Beck, Roy W.
    [J]. DIABETES CARE, 2017, 40 (04) : 538 - 545
  • [2] Bailey Timothy S, 2015, J Diabetes Sci Technol, V9, P209, DOI 10.1177/1932296814559746
  • [3] Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range
    Battelino, Tadej
    Danne, Thomas
    Bergenstal, Richard M.
    Amiel, Stephanie A.
    Beck, Roy
    Biester, Torben
    Bosi, Emanuele
    Buckingham, Bruce A.
    Cefalu, William T.
    Close, Kelly L.
    Cobelli, Claudio
    Dassau, Eyal
    DeVries, J. Hans
    Donaghue, Kim C.
    Dovc, Klemen
    Doyle, Francis J.
    Garg, Satish
    Grunberger, George
    Heller, Simon
    Heinemann, Lutz
    Hirsch, Irl B.
    Hovorka, Roman
    Jia, Weiping
    Kordonouri, Olga
    Kovatchev, Boris
    Kowalski, Aaron
    Laffel, Lori
    Levine, Brian
    Mayorov, Alexander
    Mathieu, Chantal
    Murphy, Helen R.
    Nimri, Revital
    Norgaard, Kirsten
    Parkin, Christopher G.
    Renard, Eric
    Rodbard, David
    Saboo, Banshi
    Schatz, Desmond
    Stoner, Keaton
    Urakami, Tatsuiko
    Weinzimer, Stuart A.
    Phillip, Moshe
    [J]. DIABETES CARE, 2019, 42 (08) : 1593 - 1603
  • [4] Validation of Time in Range as an Outcome Measure for Diabetes Clinical Trials
    Beck, Roy W.
    Bergenstal, Richard M.
    Riddlesworth, Tonya D.
    Kollman, Craig
    Li, Zhaomian
    Brown, Adam S.
    Close, Kelly L.
    [J]. DIABETES CARE, 2019, 42 (03) : 400 - 405
  • [5] Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin Injections The DIAMOND Randomized Clinical Trial
    Beck, Roy W.
    Riddlesworth, Tonya
    Ruedy, Katrina
    Ahmann, Andrew
    Bergenstal, Richard
    Haller, Stacie
    Kollman, Craig
    Kruger, Davida
    McGill, Janet B.
    Polonsky, William
    Toschi, Elena
    Wolpert, Howard
    Price, David
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2017, 317 (04): : 371 - 378
  • [6] Glucose Management Indicator (GMI): A New Term for Estimating A1C From Continuous Glucose Monitoring
    Bergenstal, Richard M.
    Beck, Roy W.
    Close, Kelly L.
    Grunberger, George
    Sacks, David B.
    Kowalski, Aaron
    Brown, Adam S.
    Heinemann, Lutz
    Aleppo, Grazia
    Ryan, Donna B.
    Riddlesworth, Tonya D.
    Cefalu, William T.
    [J]. DIABETES CARE, 2018, 41 (11) : 2275 - 2280
  • [7] Bergenstal RM, 2018, ANN INTERN MED, V168, P232, DOI 10.7326/L17-0589
  • [8] International Consensus on Use of Continuous Glucose Monitoring
    Danne, Thomas
    Nimri, Revital
    Battelino, Tadej
    Bergenstal, Richard M.
    Close, Kelly L.
    DeVries, J. Hans
    Garg, Satish
    Heinemann, Lutz
    Hirsch, Irl
    Amiel, Stephanie A.
    Beck, Roy
    Bosi, Emanuele
    Buckingham, Bruce
    Cobelli, Claudio
    Dassau, Eyal
    Doyle, Francis J., III
    Heller, Simon
    Hovorka, Roman
    Jia, Weiping
    Jones, Tim
    Kordonouri, Olga
    Kovatchev, Boris
    Kowalski, Aaron
    Laffel, Lori
    Maahs, David
    Murphy, Helen R.
    Norgaard, Kirsten
    Parkin, Christopher G.
    Renard, Eric
    Saboo, Banshi
    Scharf, Mauro
    Tamborlane, William V.
    Weinzimer, Stuart A.
    Phillip, Moshe
    [J]. DIABETES CARE, 2017, 40 (12) : 1631 - 1640
  • [9] Heinemann Lutz, 2015, J Diabetes Sci Technol, V9, P651, DOI 10.1177/1932296815575999
  • [10] TIR generated by continuous glucose monitoring is associated with peripheral nerve function in type 2 diabetes
    Li, Fengwen
    Zhang, Yinan
    Li, Huizhi
    Lu, Jingyi
    Jiang, Lan
    Vigersky, Robert A.
    Zhou, Jian
    Wang, Congrong
    Bao, Yuqian
    Jia, Weiping
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 2020, 166