Magnetic Resonance-Guided Gynecologic Brachytherapy

被引:10
作者
Damato, Antonio L. [1 ]
Viswanathan, Akila N. [1 ]
机构
[1] Brigham & Womens Hosp, Dept Radiat Oncol, Boston, MA 02115 USA
关键词
Gynecology; Brachytherapy; MR imaging; Image guidance; Quality assurance; CERVICAL-CANCER BRACHYTHERAPY; HIGH-DOSE-RATE; SOCIETY CONSENSUS GUIDELINES; LOCALLY ADVANCED-CARCINOMA; GEC-ESTRO RECOMMENDATIONS; AMERICAN BRACHYTHERAPY; INTERSTITIAL BRACHYTHERAPY; APPLICATOR RECONSTRUCTION; RADIATION-THERAPY; PDR BRACHYTHERAPY;
D O I
10.1016/j.mric.2015.05.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Gynecologic brachytherapy consists of positioning radioactive sources in catheters implanted inside a tumor. Magnetic resonance (MR) imaging provides tumor visibility and is ideal for image-guided insertions and treatment planning. It is important at first insertion and during treatment of large residual tumors potentially needing interstitial needles. Clear visibility of the tumor and the catheters is necessary for MR-guided brachytherapy. T2 sequences are ideal for tumor visibility but catheter visualization may be difficult. Active tracking and alternative sequences to improve catheter visibility have been explored. The use of digital applicator models, dummy markers, and CT-MR fusion is reviewed.
引用
收藏
页码:633 / +
页数:11
相关论文
共 57 条
[1]  
Abbe R, 1913, LANCET, V2, P524
[2]   Direct reconstruction of the Vienna applicator on MR images [J].
Berger, Daniel ;
Dimopoulos, Johannes ;
Poetter, Richard ;
Kirisits, Christian .
RADIOTHERAPY AND ONCOLOGY, 2009, 93 (02) :347-351
[3]   PHYSICS CONTRIBUTIONS AND CLINICAL OUTCOME WITH 3D-MRI-BASED PULSED-DOSE-RATE INTRACAVITARY BRACHYTHERAPY IN CERVICAL CANCER PATIENTS [J].
Chargari, Cyrus ;
Magne, Nicolas ;
Dumas, Isabelle ;
Messai, Taha ;
Vicenzi, Lisa ;
Gillion, Norman ;
Morice, Philippe ;
Haie-Meder, Christine .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (01) :133-139
[4]   Impact of 3D image-based PDR brachytherapy on outcome of patients treated for cervix carcinoma in France: Results of the French STIC prospective study [J].
Charra-Brunaud, Claire ;
Harter, Valentin ;
Delannes, Martine ;
Haie-Meder, Christine ;
Quetin, Philippe ;
Kerr, Christine ;
Castelain, Bernard ;
Thomas, Laurence ;
Peiffert, Didier .
RADIOTHERAPY AND ONCOLOGY, 2012, 103 (03) :305-313
[5]   Redesign of process map to increase efficiency: Reducing procedure time in cervical cancer brachytherapy [J].
Damato, Antonio L. ;
Lee, Larissa J. ;
Bhagwat, Mandar S. ;
Buzurovic, Ivan ;
Cormack, Robert A. ;
Finucane, Susan ;
Hansen, Jorgen L. ;
O'Farrell, Desmond A. ;
Offiong, Alecia ;
Randall, Una ;
Friesen, Scott ;
Viswanathan, Akila N. .
BRACHYTHERAPY, 2015, 14 (04) :471-480
[6]   Independent brachytherapy plan verification software: Improving efficacy and efficiency [J].
Damato, Antonio L. ;
Devlin, Phillip M. ;
Bhagwat, Mandar S. ;
Buzurovic, Ivan ;
Friesen, Scott ;
Hansen, Jorgen L. ;
Lee, Larissa J. ;
Molodowitch, Christina ;
Nguyen, Paul L. ;
O'Farrell, Desmond A. ;
Viswanathan, Akila N. ;
Williams, Christopher L. ;
Killoran, Joseph H. ;
Cormack, Robert A. .
RADIOTHERAPY AND ONCOLOGY, 2014, 113 (03) :420-424
[7]   A system to use electromagnetic tracking for the quality assurance of brachytherapy catheter digitization [J].
Damato, Antonio L. ;
Viswanathan, Akila N. ;
Don, Sarah M. ;
Hansen, Jorgen L. ;
Cormack, Robert A. .
MEDICAL PHYSICS, 2014, 41 (10)
[8]   Dosimetric Consequences of Interobserver Variability in Delineating the Organs at Risk in Gynecologic Interstitial Brachytherapy [J].
Damato, Antonio L. ;
Townamchai, Kanopkis ;
Albert, Michele ;
Bair, Ryan J. ;
Cormack, Robert A. ;
Jang, Joanne ;
Kovacs, Arpad ;
Lee, Larissa J. ;
Mak, Kimberley S. ;
Mirabeau-Beale, Kristina L. ;
Mouw, Kent W. ;
Phillips, John G. ;
Pretz, Jennifer L. ;
Russo, Andrea L. ;
Lewis, John H. ;
Viswanathan, Akila N. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 89 (03) :674-681
[9]   Characterization of implant displacement and deformation in gynecologic interstitial brachytherapy [J].
Damato, Antonio L. ;
Cormack, Robert A. ;
Viswanathan, Akila N. .
BRACHYTHERAPY, 2014, 13 (01) :100-109
[10]   Optimization of high-dose-rate cervix brachytherapy applicator placement: The benefits of intraoperative ultrasound guidance [J].
Davidson, Melanie T. M. ;
Yuen, Jasper ;
D'Souza, David P. ;
Radwan, John S. ;
Hammond, J. Alex ;
Batchelar, Deidre L. .