Investigating antibody-antigen binding with atomic force microscopy

被引:39
|
作者
Ouerghi, O
Touhami, A
Othmane, A [1 ]
Ben Ouada, H
Martelet, C
Fretigny, C
Jaffrezic-Renault, N
机构
[1] Fac Med Monastir, Biophys Lab, Monastir, Tunisia
[2] Fac Sci Monastir, Lab Phys Interfaces, Monastir, Tunisia
[3] Ecole Cent Lyon, UMR 5621, Lab Ingn & Fonctionnalisat Surfaces, F-69131 Ecully, France
[4] ESPCI, Phys Quant Lab, F-75005 Paris 05, France
关键词
atomic force microscopy; IgG; IgG moieties; immune complex; biosensors;
D O I
10.1016/S0925-4005(02)00020-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Adhesive interactions between antigen-antibody play a central role in immune system operation. The objective of this paper is to detect immune complexes without any label. by using atomic force microscopy (AFM). We have proceeded by imaging antibody (anti-rabbit IgG) or anti-rabbit IgG moieties adsorbed onto mica surface, before and after incubation of two kinds of antigens: a specific (rabbit IgG) and a nonpecific one (sheep IgG). The analysis using the height histograms reveals many interesting features. We propose a general framework for interpreting height histogram measurements, which enable the discrimination between specific and non-specific complexes. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:167 / 175
页数:9
相关论文
共 50 条
  • [1] Bioactive surfaces for antibody-antigen complex detection by Atomic Force Microscopy
    Ierardi, Vincenzo
    Ferrera, Francesca
    Millo, Enrico
    Damonte, Gianluca
    Filaci, Gilberto
    Valbusa, Ugo
    6TH VACUUM AND SURFACE SCIENCES CONFERENCE OF ASIA AND AUSTRALIA (VASSCAA-6), 2013, 439
  • [2] Single antibody-antigen recognition events measured by atomic force microscopy
    Hinterdorfer, P
    Raab, A
    Badt, D
    Gruber, H
    Baumgartner, W
    Schindler, H
    EUROPEAN JOURNAL OF CELL BIOLOGY, 1997, 74 : 71 - 71
  • [3] Simultaneous height and adhesion imaging of antibody-antigen interactions by atomic force microscopy
    Willemsen, OH
    Snel, MME
    van der Werf, KO
    de Grooth, BG
    Greve, J
    Hinterdorfer, P
    Gruber, HJ
    Schindler, H
    van Kooyk, Y
    Figdor, CG
    BIOPHYSICAL JOURNAL, 1998, 75 (05) : 2220 - 2228
  • [4] Detection and localization of individual antibody-antigen recognition events by atomic force microscopy
    Hinterdorfer, P
    Baumgartner, W
    Gruber, HJ
    Schilcher, K
    Schindler, H
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (08) : 3477 - 3481
  • [5] Investigating specific antigen/antibody binding with the atomic force microscope
    Ouerghi, O
    Touhami, A
    Othmane, A
    Ben Ouada, H
    Martelet, C
    Fretigny, C
    Jaffrezic-Renault, N
    BIOMOLECULAR ENGINEERING, 2002, 19 (2-6): : 183 - 188
  • [6] In situ single-molecule detection of antibody-antigen binding by tapping-mode atomic force microscopy
    Li, LY
    Chen, SF
    Oh, SJ
    Jiang, SY
    ANALYTICAL CHEMISTRY, 2002, 74 (23) : 6017 - 6022
  • [7] Direct imaging of antigen–antibody binding by atomic force microscopy
    Jing Hu
    Mingyan Gao
    Zuobin Wang
    Yujuan Chen
    Zhengxun Song
    Hongmei Xu
    Applied Nanoscience, 2021, 11 : 293 - 300
  • [8] Methods for reducing nonspecific interaction in antibody-antigen assay via atomic force microscopy
    Wakayama, Jun'ichi
    Sekiguchi, Hiroshi
    Akanuma, Satoshi
    Ohtani, Toshio
    Sugiyama, Shigeru
    ANALYTICAL BIOCHEMISTRY, 2008, 380 (01) : 51 - 58
  • [9] Force spectroscopy of antibody-antigen recognition measured by scanning force microscopy
    Hinterdorfer, P
    Raab, A
    Badt, D
    Smith-Gill, SJ
    Schindler, H
    BIOPHYSICAL JOURNAL, 1998, 74 (02) : A186 - A186
  • [10] Comparison of antibody-antigen interactions on collagen measured by conventional immunological techniques and atomic force microscopy
    Avci, R
    Schweitzer, M
    Boyd, RD
    Wittmeyer, J
    Steele, A
    Toporski, J
    Beech, W
    Arce, FT
    Spangler, B
    Cole, KM
    McKay, DS
    LANGMUIR, 2004, 20 (25) : 11053 - 11063