SEM observations and differential scanning calorimetric studies of new and sterilized nickel-titanium rotary endodontic instruments

被引:28
作者
Alexandrou, Georgia B.
Chrissafis, Konstantinos
Vasiliadis, Leonidas P. [1 ]
Pavlidou, Eleni
Polychroniadis, E. K.
机构
[1] Aristotle Univ Thessaloniki, Dept Endodontol, Sch Dent, Thessaloniki 54124, Greece
[2] Aristotle Univ Thessaloniki, Dept Phys, Solid State Phys Sect, Thessaloniki 54124, Greece
关键词
DSC; flexmaster; nickel-titanium endodontic instruments; ProFile; sterilization;
D O I
10.1016/j.joen.2006.01.003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Scanning electron microscopy (SEM) and differential scanning calorimetric (DSC) studies were utilized to investigate surface and microstructure of two brands of rotary nickel-titanium (NiTi) endodontic instruments, in the as-received condition and after subjection to 1, 6, and 11 sterilization cycles. A total of 66 ProFile (n = 33) and Flexmaster (n = 33) files were examined. SEM observations indicated the presence of surface imperfections and adherent material in all new and sterilized instruments and an increase in surface roughness of the instruments that underwent multiple sterilizations. DSC measurements showed that the specimens of both brands, in the as-received condition and after 11 sterilizations, were completely austenite in the oral environment temperature, suggesting that they are capable of superelastic behavior in appropriate clinical conditions.
引用
收藏
页码:675 / 679
页数:5
相关论文
共 38 条
[21]  
Melton K. N., 1990, ENG ASPECTS SHAPE ME, V344, P21
[22]   Effect of sterilization on cyclic fatigue of rotary nickel-titanium endodontic instruments [J].
Mize, SB ;
Clement, DJ ;
Pruett, JP ;
Carnes, DL .
JOURNAL OF ENDODONTICS, 1998, 24 (12) :843-847
[23]   Effect of sterilization on the cutting efficiency of rotary nickel-titanium endodontic files [J].
Rapisarda, E ;
Bonaccorso, A ;
Tripi, TR ;
Condorelli, GG .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1999, 88 (03) :343-347
[24]   The effect of surface treatments of nickel-titanium files on wear and cutting efficiency [J].
Rapisarda, E ;
Bonaccorso, A ;
Tripi, TR ;
Fragalk, I ;
Condorelli, GG .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2000, 89 (03) :363-368
[25]   Wear of nickel-titanium endodontic instruments evaluated by scanning electron microscopy: Effect of ion implantation [J].
Rapisarda, E ;
Bonaccorso, A ;
Tripi, TR ;
Condorelli, GG ;
Torrisi, L .
JOURNAL OF ENDODONTICS, 2001, 27 (09) :588-592
[26]  
Schafer E, 1997, ENDOD DENT TRAUMATOL, V13, P51
[27]   Effect of sterilization on the cutting efficiency of PVD-coated nickel-titanium endodontic instruments [J].
Schäfer, E .
INTERNATIONAL ENDODONTIC JOURNAL, 2002, 35 (10) :867-872
[28]  
Serene TP, 1995, Nickel-titanium instruments: applications in endodontics
[29]   Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic files [J].
Silvaggio, J ;
Hicks, ML .
JOURNAL OF ENDODONTICS, 1997, 23 (12) :731-734
[30]   Properties of endodontic hand instruments used in rotary motion .3. Resistance to bending and fracture [J].
Tepel, J ;
Schafer, E ;
Hoppe, W .
JOURNAL OF ENDODONTICS, 1997, 23 (03) :141-145