SEM observations and differential scanning calorimetric studies of new and sterilized nickel-titanium rotary endodontic instruments

被引:28
作者
Alexandrou, Georgia B.
Chrissafis, Konstantinos
Vasiliadis, Leonidas P. [1 ]
Pavlidou, Eleni
Polychroniadis, E. K.
机构
[1] Aristotle Univ Thessaloniki, Dept Endodontol, Sch Dent, Thessaloniki 54124, Greece
[2] Aristotle Univ Thessaloniki, Dept Phys, Solid State Phys Sect, Thessaloniki 54124, Greece
关键词
DSC; flexmaster; nickel-titanium endodontic instruments; ProFile; sterilization;
D O I
10.1016/j.joen.2006.01.003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Scanning electron microscopy (SEM) and differential scanning calorimetric (DSC) studies were utilized to investigate surface and microstructure of two brands of rotary nickel-titanium (NiTi) endodontic instruments, in the as-received condition and after subjection to 1, 6, and 11 sterilization cycles. A total of 66 ProFile (n = 33) and Flexmaster (n = 33) files were examined. SEM observations indicated the presence of surface imperfections and adherent material in all new and sterilized instruments and an increase in surface roughness of the instruments that underwent multiple sterilizations. DSC measurements showed that the specimens of both brands, in the as-received condition and after 11 sterilizations, were completely austenite in the oral environment temperature, suggesting that they are capable of superelastic behavior in appropriate clinical conditions.
引用
收藏
页码:675 / 679
页数:5
相关论文
共 38 条
[1]   SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use [J].
Alapati, SB ;
Brantley, WA ;
Svec, TA ;
Powers, JM ;
Nusstein, JM ;
Daehn, GS .
JOURNAL OF ENDODONTICS, 2005, 31 (01) :40-43
[2]   Scanning electron microscope observations of new and used nickel-titanium rotary files [J].
Alapati, SB ;
Brantley, WA ;
Svec, TA ;
Powers, JM ;
Mitchell, JC .
JOURNAL OF ENDODONTICS, 2003, 29 (10) :667-669
[3]  
ANDREASEN GF, 1978, AM J ORTHOD DENTOFAC, V73, P141, DOI 10.1016/0002-9416(78)90184-7
[4]   K3 endo, ProTaper, and ProFile systems: Breakage and distortion, in severely curved roots of molars [J].
Ankrum, MT ;
Hartwell, GR ;
Truitt, JE .
JOURNAL OF ENDODONTICS, 2004, 30 (04) :234-237
[5]   Differential scanning calorimetry (DSC) analyses of superelastic and nonsuperelastic nickel-titanium orthodontic wires [J].
Bradley, TG ;
Brantley, WA ;
Culbertson, BM .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1996, 109 (06) :589-597
[6]  
Brantley W.A., 2001, Thieme., P77
[7]   Differential scanning calorimetric studies of nickel titanium rotary endodontic instruments [J].
Brantley, WA ;
Svec, TA ;
Iijima, M ;
Powers, JM ;
Grentzer, TH .
JOURNAL OF ENDODONTICS, 2002, 28 (08) :567-572
[8]   Differential scanning calorimetric studies of nickel-titanium rotary endodontic instruments after simulated clinical use [J].
Brantley, WA ;
Svec, TA ;
Iijima, M ;
Powers, JM ;
Grentzer, TH .
JOURNAL OF ENDODONTICS, 2002, 28 (11) :774-778
[9]   The effect of sterilization on bending and torsional properties of K-files manufactured with different metallic alloys [J].
Canalda-Sahli, C ;
Brau-Aguade, E ;
Sentis-Vilalta, J .
INTERNATIONAL ENDODONTIC JOURNAL, 1998, 31 (01) :48-52
[10]   POTENTIAL APPLICATIONS OF CERTAIN NICKEL-TITANIUM (NITINOL) ALLOYS [J].
CIVJAN, S ;
HUGET, EF ;
DESIMON, LB .
JOURNAL OF DENTAL RESEARCH, 1975, 54 (01) :89-96