Wearable device for remote monitoring of transcutaneous tissue oxygenation

被引:20
作者
Cascales, Juan Pedro [1 ]
Roussakis, Emmanuel [1 ]
Witthauer, Lilian [1 ]
Goss, Avery [1 ]
Li, Xiaolei [1 ]
Chen, Yenyu [1 ]
Marks, Haley L. [1 ]
Evans, Conor L. [1 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Wellman Ctr Photomed, Charlestown, MA 02129 USA
来源
BIOMEDICAL OPTICS EXPRESS | 2020年 / 11卷 / 12期
关键词
PHASE FLUOROMETER; MEASURING SYSTEM; PULSE OXIMETRY; BLOOD-FLOW; ISCHEMIA; PHOSPHORESCENCE; CALIBRATION; SENSORS; TIME; FLUX;
D O I
10.1364/BOE.408850
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Wearable devices have found widespread applications in recent years as both medical devices as well as consumer electronics for sports and health tracking. A metric of health that is often overlooked in currently available technology is the direct measurement of molecular oxygen in living tissue, a key component in cellular energy production. Here, we report on the development of a wireless wearable prototype for transcutaneous oxygenation monitoring based on quantifying the oxygen-dependent phosphorescence of a metalloporphyrin embedded within a highly breathable oxygen sensing film. The device is completely self-contained, weighs under 30 grams, performs on-board signal analysis, and can communicate with computers or smartphones. The wearable measures tissue oxygenation at the skin surface by detecting the lifetime and intensity of phosphorescence, which undergoes quenching in the presence of oxygen. As well as being insensitive to motion artifacts, it offers robust and reliable measurements even in variable atmospheric conditions related to temperature and humidity. Preliminary in vivo testing in a porcine ischemia model shows that the wearable is highly sensitive to changes in tissue oxygenation in the physiological range upon inducing a decrease in limb perfusion. (c) 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:6989 / 7002
页数:14
相关论文
共 54 条
  • [1] Incremental Database Design using UML-B and Event-B
    Al-Brashdi, Ahmed
    Butler, Michael
    Rezazadeh, Abdolbaghi
    [J]. ELECTRONIC PROCEEDINGS IN THEORETICAL COMPUTER SCIENCE, 2018, (271): : 34 - 47
  • [2] [Anonymous], COCHRANE DATABASE SY
  • [3] In vivo phosphorescence imaging of pO2 using planar oxygen sensors
    Babilas, P
    Liebsch, G
    Schacht, V
    Klimant, I
    Wolfbeis, OS
    Szeimies, RM
    Abels, C
    [J]. MICROCIRCULATION, 2005, 12 (06) : 477 - 487
  • [4] Transcutaneous pO2 imaging during tourniquet-induced forearm ischemia using planar optical oxygen sensors
    Babilas, Philipp
    Lamby, Philipp
    Prantl, Lukas
    Schreml, Stephan
    Jung, Ernst Michael
    Liebsch, Gregor
    Wolfbeis, Otto S.
    Landthaler, Michael
    Szeimies, Rolf-Markus
    Abels, Christoph
    [J]. SKIN RESEARCH AND TECHNOLOGY, 2008, 14 (03) : 304 - 311
  • [5] THE DETERMINATION OF THE FLUORESCENCE LIFETIMES OF DISSOLVED SUBSTANCES BY A PHASE SHIFT METHOD
    BAILEY, EA
    ROLLEFSON, GK
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1953, 21 (08) : 1315 - 1322
  • [6] PHASE FLUOROMETRIC STERILIZABLE OPTICAL OXYGEN SENSOR
    BAMBOT, SB
    HOLAVANAHALI, R
    LAKOWICZ, JR
    CARTER, GM
    RAO, G
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 1994, 43 (11) : 1139 - 1145
  • [7] ELECTROLUMINESCENT LAMP-BASED PHASE FLUOROMETER AND OXYGEN SENSOR
    BERNDT, KW
    LAKOWICZ, JR
    [J]. ANALYTICAL BIOCHEMISTRY, 1992, 201 (02) : 319 - 325
  • [8] Caldwell J., 2014, TI Designs - Precision: Verified Design 1 MHz, Single-Supply, Photodiode Amplifier Reference Design, P1
  • [9] Experimental investigation of the effect of polymer matrices on polymer fibre optic oxygen sensors and their time response characteristics using a vacuum testing chamber and a liquid flow apparatus
    Chen, Rongsheng
    Formenti, Federico
    McPeak, Hanne
    Obeid, Andrew N.
    Hahn, Clive
    Farmery, Andrew
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2016, 222 : 531 - 535
  • [10] LIMITATIONS OF PULSE OXIMETRY TO ASSESS LIMB VASCULARITY
    CLAY, NR
    DENT, CM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (02): : 344 - 344