Wearable device for remote monitoring of transcutaneous tissue oxygenation

被引:23
作者
Cascales, Juan Pedro [1 ]
Roussakis, Emmanuel [1 ]
Witthauer, Lilian [1 ]
Goss, Avery [1 ]
Li, Xiaolei [1 ]
Chen, Yenyu [1 ]
Marks, Haley L. [1 ]
Evans, Conor L. [1 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Wellman Ctr Photomed, Charlestown, MA 02129 USA
关键词
PHASE FLUOROMETER; MEASURING SYSTEM; PULSE OXIMETRY; BLOOD-FLOW; ISCHEMIA; PHOSPHORESCENCE; CALIBRATION; SENSORS; TIME; FLUX;
D O I
10.1364/BOE.408850
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Wearable devices have found widespread applications in recent years as both medical devices as well as consumer electronics for sports and health tracking. A metric of health that is often overlooked in currently available technology is the direct measurement of molecular oxygen in living tissue, a key component in cellular energy production. Here, we report on the development of a wireless wearable prototype for transcutaneous oxygenation monitoring based on quantifying the oxygen-dependent phosphorescence of a metalloporphyrin embedded within a highly breathable oxygen sensing film. The device is completely self-contained, weighs under 30 grams, performs on-board signal analysis, and can communicate with computers or smartphones. The wearable measures tissue oxygenation at the skin surface by detecting the lifetime and intensity of phosphorescence, which undergoes quenching in the presence of oxygen. As well as being insensitive to motion artifacts, it offers robust and reliable measurements even in variable atmospheric conditions related to temperature and humidity. Preliminary in vivo testing in a porcine ischemia model shows that the wearable is highly sensitive to changes in tissue oxygenation in the physiological range upon inducing a decrease in limb perfusion. (c) 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:6989 / 7002
页数:14
相关论文
共 54 条
[1]   Incremental Database Design using UML-B and Event-B [J].
Al-Brashdi, Ahmed ;
Butler, Michael ;
Rezazadeh, Abdolbaghi .
ELECTRONIC PROCEEDINGS IN THEORETICAL COMPUTER SCIENCE, 2018, (271) :34-47
[2]  
[Anonymous], COCHRANE DATABASE SY
[3]  
[Anonymous], 2011, The Python Language Reference Manual
[4]   In vivo phosphorescence imaging of pO2 using planar oxygen sensors [J].
Babilas, P ;
Liebsch, G ;
Schacht, V ;
Klimant, I ;
Wolfbeis, OS ;
Szeimies, RM ;
Abels, C .
MICROCIRCULATION, 2005, 12 (06) :477-487
[5]   Transcutaneous pO2 imaging during tourniquet-induced forearm ischemia using planar optical oxygen sensors [J].
Babilas, Philipp ;
Lamby, Philipp ;
Prantl, Lukas ;
Schreml, Stephan ;
Jung, Ernst Michael ;
Liebsch, Gregor ;
Wolfbeis, Otto S. ;
Landthaler, Michael ;
Szeimies, Rolf-Markus ;
Abels, Christoph .
SKIN RESEARCH AND TECHNOLOGY, 2008, 14 (03) :304-311
[6]   THE DETERMINATION OF THE FLUORESCENCE LIFETIMES OF DISSOLVED SUBSTANCES BY A PHASE SHIFT METHOD [J].
BAILEY, EA ;
ROLLEFSON, GK .
JOURNAL OF CHEMICAL PHYSICS, 1953, 21 (08) :1315-1322
[7]   PHASE FLUOROMETRIC STERILIZABLE OPTICAL OXYGEN SENSOR [J].
BAMBOT, SB ;
HOLAVANAHALI, R ;
LAKOWICZ, JR ;
CARTER, GM ;
RAO, G .
BIOTECHNOLOGY AND BIOENGINEERING, 1994, 43 (11) :1139-1145
[8]   ELECTROLUMINESCENT LAMP-BASED PHASE FLUOROMETER AND OXYGEN SENSOR [J].
BERNDT, KW ;
LAKOWICZ, JR .
ANALYTICAL BIOCHEMISTRY, 1992, 201 (02) :319-325
[9]  
Caldwell J., 2014, TI Designs - Precision: Verified Design 1 MHz, Single-Supply, Photodiode Amplifier Reference Design, P1
[10]   Experimental investigation of the effect of polymer matrices on polymer fibre optic oxygen sensors and their time response characteristics using a vacuum testing chamber and a liquid flow apparatus [J].
Chen, Rongsheng ;
Formenti, Federico ;
McPeak, Hanne ;
Obeid, Andrew N. ;
Hahn, Clive ;
Farmery, Andrew .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 222 :531-535