Quantitation of Zygomatic Complex Symmetry Using 3-Dimensional Computed Tomography

被引:19
作者
Gong, Xi [1 ]
He, Ying [1 ]
He, Yang [1 ]
An, Jin-gang [1 ]
Yang, Yao [1 ]
Zhang, Yi [1 ]
机构
[1] Peking Univ, Dept Oral & Maxillofacial Surg, Sch & Hosp Stomatol, Beijing 100081, Peoples R China
关键词
ASYMMETRY; NAVIGATION; FRACTURES; IMAGES;
D O I
10.1016/j.joms.2014.06.447
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To improve the clinical evaluation of the symmetry of the zygomatic complex (ZMC), the authors developed a new method to measure the eminence and width of the ZMC using 3-dimensional (3D) computed tomography (CT). The accuracy and reproducibility of the ZMC symmetry evaluation using this method were investigated. Materials and Methods: Spiral CT was carried out in 50 volunteers with visually symmetric faces. Based on an exact craniofacial midsagittal plane, a 3D coordinate system was constructed and used to measure the eminence and width of the ZMC. Absolute differences between the bilateral eminences and widths were calculated as Delta E and Delta W, respectively. The ZMC eminence also was measured based on traditional methods using anatomic landmarks, and the bilateral absolute difference was calculated to serve as a control (Delta cE). Results: The Delta E value was lower than the Delta cE value (0.6 vs 1.75 mm; P < .001). None of the results for DE were larger than 2 mm, and 7 results (3.5%) for Delta W were larger than 2 mm. By comparison, 57 results (28.5%) for Delta cE were larger than 2 cm (P < .001). The intraclass correlation coefficient (ICC) indicated almost perfect agreement for inter- and intraexaminer reliabilities for Delta E (ICC, 0.82 to 0.86) and Delta W (ICC, 0.81 to 0.85) measurements, and moderate agreement for inter-and intraexaminer reliabilities was obtained for Delta cE (ICC, 0.61 to 0.68) measurements. Conclusion: This new method is practical and valuable in the clinical evaluation of ZMC symmetry. (C) 2014 American Association of Oral and Maxillofacial Surgeons
引用
收藏
页码:2053.e1 / 2053.e8
页数:8
相关论文
共 19 条
[1]   CHANGING PATTERNS IN THE EPIDEMIOLOGY AND TREATMENT OF ZYGOMA FRACTURES - 10-YEAR REVIEW [J].
COVINGTON, DS ;
WAINWRIGHT, DJ ;
TEICHGRAEBER, JF ;
PARKS, DH .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1994, 37 (02) :243-248
[2]   Quantitative topographical evaluation of the orbitozygomatic complex [J].
Czerwinski, M ;
Martin, M ;
Lee, C .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2005, 115 (07) :1858-1862
[3]   A three-dimensional comparison of a morphometric and conventional cephalometric midsagittal planes for craniofacial asymmetry [J].
Damstra, Janalt ;
Fourie, Zacharias ;
De Wit, Marnix ;
Ren, Yijin .
CLINICAL ORAL INVESTIGATIONS, 2012, 16 (01) :285-294
[4]   Analysis of treatment for isolated zygomaticomaxillary complex fractures [J].
Ellis, E ;
Kittidumkerng, W .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 54 (04) :386-400
[5]  
FARKAS LG, 1981, ANGLE ORTHOD, V51, P70
[6]   The use of computed tomography to define zygomatic complex position [J].
Furst, IM ;
Austin, P ;
Pharoah, M ;
Mahoney, J .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 59 (06) :647-654
[7]   Reliability of a method for computing facial symmetry plane and degree of asymmetry based on 3D-data [J].
Hartmann, Jutta ;
Meyer-Marcotty, Philipp ;
Benz, Michaela ;
Haeusler, Gerd ;
Stellzig-Eisenhauer, Angelika .
JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2007, 68 (06) :477-490
[8]   Zygomatic Surface Marker-Assisted Surgical Navigation: A New Computer-Assisted Navigation Method for Accurate Treatment of Delayed Zygomatic Fractures [J].
He, Yang ;
Zhang, Yi ;
An, Jin-gang ;
Gong, Xi ;
Feng, Zhi-qiang ;
Guo, Chuan-bin .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (12) :2101-2114
[9]   Evaluation of complex craniomaxillofacial fractures by a new three-dimensional planning system [J].
Holmes, Simon ;
Goldner, Sean ;
Bridle, Chris ;
Chin-Shong, David ;
Visram, Karima .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2006, 44 (05) :416-417
[10]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174