Morphologic and functional assessment of vascular abnormalities of the pulmonary vasculature by breath-hold MR techniques

被引:9
作者
Mohrs, OK
Voigtländer, T
Heussel, CP
Von Bardeleben, S
Düber, C
Kreitner, KF
机构
[1] Johannes Gutenberg Univ Mainz, Klin & Poliklin Radiol, D-55131 Mainz, Germany
[2] Johannes Gutenberg Univ Mainz, Med Klin 2, D-6500 Mainz, Germany
[3] Klinikum Mannheim GMBH, Inst Klin Radiol, Mannheim, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2002年 / 174卷 / 04期
关键词
arteriovenous malformation; partial anomalous pulmonar venous return; MR angiography; flow measurement; shunt quantification;
D O I
10.1055/s-2002-25115
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate breath-hold MR techniques for morphologic and functional assessment of vascular abnormalities of the pulmonary vasculature. Patients and Methods: 13 patients aged 11 to 60 years with different vascular abnormalities of the pulmonary vasculature (5 patients with 16 arteriovenous malformations, 8 patients with partial anomalous pulmonary venous return) underwent MR imaging at 1.5 T. For morphological assessment, a contrast-enhanced 3D MR angiography (ce-MRA) was performed after a timing run. Segmented cine- and velocity-encoded GRE sequences were used for delineation of associated cardiac septal defects and for determination of systemic left-to-right or intrapulmonary shunt volumes. Selective intra arterial digital subtraction angiography, cardiac catheterization, and the intraoperative situs served as reference standards. Results: Ce-MRA allowed for detection of all vascular abnormalities and for anatomic characterization of 14/16 arteriovenous malformations. Flow measurements in the feeding arteries allowed for determination of intrapulmonary shunt volumes in 4/5 patients. Flow measurements performed in the pulmonary arteries and the ascending aorta enabled determination of systemic left-to-right shunting in patients with anomalous pulmonary venous return. Cine-sequences clearly depicted associated cardiac septal defects. Conclusion: Breath-hold MR techniques allow for morphological and functional characterization of vascular anomalies of the pulmonary vasculature. Therefore, they are the non-invasive method of choice for planning further treatment.
引用
收藏
页码:467 / 473
页数:7
相关论文
共 35 条
[1]   ANOMALOUS PULMONARY VENOUS RETURN WITH INTACT ATRIAL SEPTUM - DIAGNOSIS AND PATHOPHYSIOLOGY [J].
ALPERT, JS ;
DEXTER, L ;
VIEWEG, WVR ;
HAYNES, FW ;
DALEN, JE .
CIRCULATION, 1977, 56 (05) :870-875
[2]   ADVANTAGES AND LIMITATIONS OF METHODS TO DETECT, LOCALIZE, AND QUANTITATE INTRACARDIAC LEFT-TO-RIGHT SHUNTING [J].
BOEHRER, JD ;
LANGE, RA ;
WILLARD, JE ;
GRAYBURN, PA ;
HILLIS, LD .
AMERICAN HEART JOURNAL, 1992, 124 (02) :448-454
[3]   MR angiography of the thoracic vessels [J].
Bongartz, G ;
Boos, M ;
Winter, K ;
Brandli, M ;
Scheffler, K .
RADIOLOGE, 1997, 37 (07) :529-538
[4]  
Bremerich J, 1999, ROFO-FORTSCHR RONTG, V170, P397
[5]   OXIMETRIC QUANTITATION OF INTRACARDIAC LEFT-TO-RIGHT SHUNTING - LIMITATIONS OF THE QP/QS RATIO [J].
CIGARROA, RG ;
LANGE, RA ;
HILLIS, LD .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (03) :246-247
[6]   OXIMETRIC VERSUS INDICATOR DILUTION TECHNIQUES FOR QUANTITATING INTRACARDIAC LEFT-TO-RIGHT SHUNTING IN ADULTS [J].
DANIEL, WC ;
LANGE, RA ;
WILLARD, JE ;
LANDAU, C ;
HILLIS, LD .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (02) :199-200
[7]   PULMONARY ARTERIOVENOUS-MALFORMATIONS - RESULTS OF TREATMENT WITH COIL EMBOLIZATION IN 53 PATIENTS [J].
DUTTON, JAE ;
JACKSON, JE ;
HUGHES, JMB ;
WHYTE, MKB ;
PETERS, AM ;
USSOV, W ;
ALLISON, DJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (05) :1119-1125
[8]   CT of spontaneous hemothorax from intrapleural rupture of a pulmonary arteriovenous malformation [J].
Edinburgh, KJ ;
Chung, MH ;
Webb, WR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (05) :1399-1400
[9]   Pulmonary arteriovenous malformations - A state of the art review [J].
Gossage, JR ;
Kanj, G .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (02) :643-661
[10]   Pulmonary arteriovenous malformation:: Characterization with time-resolved ultrafast 3D MR angiography [J].
Goyen, M ;
Ruehm, SG ;
Jagenburg, A ;
Barkhausen, J ;
Kröger, K ;
Debatin, JF .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (03) :458-460