Estimation of EEC, unattached fraction and equilibrium factor for the assessment of radiological dose using pin-hole cup dosimeters and deposition based progeny sensors

被引:32
作者
Bangotra, Pargin [1 ]
Mehra, Rohit [1 ]
Kaur, Kirandeep [1 ]
Kanse, Sandeep [2 ]
Mishra, Rosaline [2 ]
Sahoo, B. K. [2 ]
机构
[1] Dr BR Ambedkar Natl Inst Technol, Dept Phys, Jalandhar, Punjab, India
[2] Bhabha Atom Res Ctr, Radiol Phys & Advisory Div, Bombay 400085, Maharashtra, India
关键词
Pin-hole cup dosimeters; DTPS/DRPS; EEC; Unattached fraction; DCF; Annual effective dose; INDOOR RADON PROGENY; THORON PROGENY; CONVERSION FACTORS; UNIT EXPOSURE;
D O I
10.1016/j.jenvrad.2015.06.010
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
High concentration of radon (Rn-222) thoron (Rn-220) and their decay products in environment may increase the risk of radiological exposure to the mankind. The Rn-222, Rn-220 concentration and their separate attached and unattached progeny concentration in units of EEC have been measured in the dwellings of Muktsar and Mansa districts of Punjab (India), using Pin-hole cup dosimeters and deposition based progeny sensors (DTPS/DRPS). The indoor Rn-222 and Rn-220 concentration was found to vary from 21 Bqm(-3) to 94 Bqm-3 and 17 Bqm-3 to 125 Bqm-3. The average EEC (attached + unattached) of Rn-222 and Rn-220 was 25 Bqm(-3) and 1.8 Bqm(-3). The equilibrium factor for Rn-222 and Rn-220 in studied area was 0.47 +/- 0.13 and 0.05 +/- 0.03. The equilibrium factor and unattached fraction of Rn-222 and Rn-220 has been calculated separately. Dose conversion factors (DCFs) of different models have been calculated from unattached fraction for the estimation of annual effective dose in the studied area. From the experimental data a correlation relationship has been observed between unattached fraction (f(p)(Rn)) and equilibrium factor (FRO. The present work also aims to evaluate an accurate expression among available expression in literature for the estimation of f(p)(Rn). (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:67 / 73
页数:7
相关论文
共 36 条
  • [1] Inhalation dose assessment of indoor radon progeny using biokinetic and dosimetric modeling and its application to Jordanian population
    Al-Jundi, J.
    Li, W. B.
    Abusini, M.
    Tschiersch, J.
    Hoeschen, C.
    Oeh, U.
    [J]. JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2011, 102 (06) : 574 - 580
  • [2] [Anonymous], On Serpa's work at the Biblioteca Nacional
  • [3] [Anonymous], 1990, TECHNICAL REPORT SER
  • [4] [Anonymous], AM J EPIDEMIOL
  • [5] [Anonymous], J ENV SCI ENG
  • [6] [Anonymous], ENV INT
  • [7] [Anonymous], EXP DUE NAT RAD SOUR
  • [8] [Anonymous], ICRP PUBL
  • [9] [Anonymous], 2005, BMJ-BRIT MED J, DOI DOI 10.1136/bmj.38308.477650.63
  • [10] [Anonymous], 0090209 ICRP