Investigation on Flow-Induced Vibrations of a Steam Turbine Inlet Valve Considering Fluid-Structure Interaction Effects

被引:19
作者
Domnick, Clemens Bernhard [1 ]
Benra, Friedrich-Karl [1 ]
Brillert, Dieter [1 ]
Dohmen, Hans Josef [1 ]
Musch, Christian [2 ]
机构
[1] Univ Duisburg Essen, Turbomachinery, Forsthausweg 2, D-47057 Duisburg, Germany
[2] Siemens AG, D-45478 Mulheim, Germany
来源
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME | 2017年 / 139卷 / 02期
关键词
Fluid structure interaction - Steam - Finite element method - Steam turbines - Feedback control - Dynamic loads - Fighter aircraft;
D O I
10.1115/1.4034352
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The power output of steam turbines is controlled by steam turbine inlet valves. These valves have a large flow capacity and dissipate a huge amount of energy in throttled operation. The dissipation process generates strong pressure fluctuations resulting in high dynamic forces causing valve vibrations. A brief survey of the literature dealing with valve vibrations reveals that the vibrational problems and damages mostly occur in throttled operation when high speed jets, shocks, and shear layers are present. As previous investigations reveal that a feedback mechanism between the dynamic flow field and the vibrating valve plug exists, the vibrations are investigated with two-way coupled simulations. The fluid dynamics are solved with a scale-adaptive approach to resolve the pressure fluctuations generated by the turbulent flow. The finite element model (FEM) solving the structural dynamics considers both frictional effects at the valve packing and contact effects caused by the plug impacting on the valve bushing. As different flow topologies causing diverse dynamic loads exist, the fluid flow and the structural dynamics are simulated at different operating points. The simulations show that differences to the oneway-coupled approach exist leading to a change of the vibrational behavior. The physics behind the feedback mechanisms causing this change are analyzed and conclusions regarding the accuracy of the one-way-coupled approach are drawn.
引用
收藏
页数:10
相关论文
共 29 条
[1]  
[Anonymous], NASATM2010216339
[2]  
Bianchini C., 2015, GT201542473 ASME
[3]  
Clari M.B., 2011, GT201145617 ASME, DOI [10.1115/GT2011-45617, DOI 10.1115/GT2011-45617]
[4]  
Darwish M., 1977, ADV INSTRUM, V32, P79
[5]  
Domnick C. B., 2014, ISROMAC 15
[6]  
Domnick C. B., 2015, GT201542182 ASME
[7]  
Domnick C. B., 2015, C MOD FLUID FLOW CMF
[8]   Numerical Investigation on the Time-Variant Flow Field and Dynamic Forces Acting in Steam Turbine Inlet Valves [J].
Domnick, Clemens Bernhard ;
Benra, Friedrich-Karl ;
Brillert, Dieter ;
Dohmen, Hans Josef ;
Musch, Christian .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2015, 137 (08)
[9]  
Egorov Y, 2008, ADVANCES IN HYBRID RANS-LES MODELLING, P261
[10]  
Erodi I. T., 2015, C MOD FLUID FLOW CMF