摘要
Forest soils often contain many large coarse fragments making it difficult to insert probes to measure soil water content. The ability of time domain reflectometry (TDR) to give reliable measurements of water content in soil with up to 40% coarse fragments was evaluated at a site in the southern interior of British Columbia, Canada. A commercial time domain reflectometer was used with 0.3-, 0.5- and 0.75-m-long probes to measure soil water content of the profile and layers within the profile. A probe had a shorting diode at the surface and two 3-mm-diameter stainless steel rods inserted vertically, 30 mm apart, as the waveguide. Diverging rods or profile discontinuities resulted in erroneous readings that required a review of the recorded signals and recalculation the travel time. Soil physical and hydrologic soil properties were determined and the soil calibrated for TDR. An accuracy of +/-0.02 m(3) m(-3) was obtained with measurement of soil bulk density and minimizing probe and travel time errors. Variation in water content between probes reflected the variability in coarse fragment content; however, the ranking of the probes stayed constant with time and rates of change were similar between probes. One standard deviation on the measured change in the volume of water between measurement days for the 0 to 0.5 m depth was +/-6 mm (n = 20), equivalent to 0.012 m(3) m(-3). Measurements of water content of the layers had one standard deviation of 0.02 m(3) m(-3).
引用
收藏
页码:3 / 11
页数:9
相关论文
共 50 条
  • [41] Active Scour Monitoring using Ultrasonic Time-Domain Reflectometry to Detect a Soil Interface
    Funderburk, Morgan L.
    Todd, Michael D.
    Netchaev, Anton
    Loh, Kenneth J.
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2021, 2021, 11591
  • [42] WATER-CONTENT MEASUREMENT IN FOREST SOILS AND DECAYED WOOD USING TIME-DOMAIN REFLECTOMETRY
    GRAY, AN
    SPIES, TA
    CANADIAN JOURNAL OF FOREST RESEARCH-REVUE CANADIENNE DE RECHERCHE FORESTIERE, 1995, 25 (03): : 376 - 385
  • [43] The effect of soil texture on the time domain reflectometry calibration for soil water content measurement
    Chudinova, SM
    Ponizovskii, AA
    EURASIAN SOIL SCIENCE, 1998, 31 (01) : 17 - 24
  • [44] INTERCONNECT CHARACTERIZATION USING TIME-DOMAIN REFLECTOMETRY
    COREY, SD
    YANG, AT
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1995, 43 (09) : 2151 - 2156
  • [45] Monitoring subsidence mechanisms using time domain reflectometry
    O'Connor, KM
    Norland, MR
    LAND SUBSIDENCE CASE STUDIES AND CURRENT RESEARCH: PROCEEDINGS OF THE DR. JOSEPH F. POLAND SYMPOSIUM ON LAND SUBSIDENCE, 1998, (08): : 427 - 434
  • [47] Effects of Temperature on Measurements of Soil Water Content with Time Domain Reflectometry
    Schanz, Tom
    Baille, Wiebke
    Long Nguyen Tuan
    GEOTECHNICAL TESTING JOURNAL, 2011, 34 (01): : 1 - 8
  • [48] Assessing soil volumetric water content and salinity by time domain reflectometry
    Aringhieri, R
    Giachetti, M
    PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON TECHNIQUES TO CONTROL SALINATION FOR HORTICULTURAL PRODUCTIVITY, 2002, (573): : 29 - 34
  • [49] Rapid measurement of soil matric suction by time-domain reflectometry
    He, L
    Leong, EC
    Rahardjo, H
    FIELD MEASUREMENTS OF GEOMECHANICS, 1999, : 543 - 548
  • [50] Use of Time Domain Reflectometry probes for monitoring unsaturated soil pollution
    Alimi-Ichola, I
    ENVIRONMENTAL GEOTECHNICS, VOLS 1-4, 1998, : 107 - 112