Enhancing osseointegration of titanium implants through large-grit sandblasting combined with micro-arc oxidation surface modification

被引:45
作者
He, Wulin [1 ]
Yin, Xing [2 ,3 ]
Xie, Li [2 ,3 ,4 ]
Liu, Zeping [2 ,3 ]
Li, Jingtao [2 ,3 ]
Zou, Shujuan [2 ,3 ]
Chen, Jianwei [2 ,3 ]
机构
[1] Southern Med Univ, Stomatol Hosp, 366 South Jiangnan Ave, Guangzhou 510280, Guangdong, Peoples R China
[2] Sichuan Univ, State Key Lab Oral Dis, West China Hosp Stomatol, Chengdu 610041, Sichuan, Peoples R China
[3] Sichuan Univ, Natl Clin Res Ctr Oral Dis, West China Hosp Stomatol, Chengdu 610041, Sichuan, Peoples R China
[4] Sichuan Univ, Coll Mat Sci & Engn, Chengdu 610064, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
IN-VITRO BIOACTIVITY; BIOLOGICAL-PROPERTIES; BONE;
D O I
10.1007/s10856-019-6276-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeThe demand for titanium dental implants has risen sharply. However, the clinical success rate of implant surgery needs to be improved. In this paper, we report a novel surface modification strategy, large-grit sandblasting combined with micro-arc oxidation (SL-MAO), aiming to promote peri-implant bone formation and osseointegration of titanium implants.Materials and methodsModified titanium samples were prepared by large-grit sandblasting and acid etching (SLA), micro-arc oxidation (MAO), and SL-MAO. The resulting topographical changes and chemical composition of the samples were examined by scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS), respectively, and the biocompatibility and bioactivity were analyzed by bone-marrow mesenchymal stem cells (BMMSC) adhesion tests. Modified titanium implants were also inserted into the femurs of beagle dogs, and their competence of osseointegration was appraised by quantitative histomorphometry and micro-computed-tomography (micro-CT) analyses.ResultsCompared to SLA and MAO techniques, SL-MAO surface modification further enhanced titanium surfaces by creating a topographic morphology characterized by both micron-sized craters and sub-micron-scale pits, and resulted in superior chemical composition, which promoted cell adhesion, proliferation, and osteogenic differentiation. SL-MAO-modified titanium implants osseointegrated more efficiently than SLA or MAO controls, with significantly higher bone-area (BA) ratio and bone-implant contact (BIC) in the peri-implant region.ConclusionsThe SL-MAO surface modification technique optimized the surface properties of titanium implants and enhanced peri-implant bone formation and osseointegration.
引用
收藏
页数:11
相关论文
共 38 条
[1]   "Peri-Implantitis": A Complication of a Foreign Body or a Man-Made "Disease". Facts and Fiction [J].
Albrektsson, Tomas ;
Canullo, Luigi ;
Cochran, David ;
De Bruyn, Hugo .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (04) :840-849
[2]  
Becker W, 2000, Clin Implant Dent Relat Res, V2, P159, DOI 10.1111/j.1708-8208.2000.tb00007.x
[3]   CRITICAL SUMMARIES There is not an optimum number of implants for an overdenture [J].
Byrne, Gerard .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2015, 146 (10) :773-774
[4]   Multiscale Analyses of the Bone-implant Interface [J].
Cha, J. Y. ;
Pereira, M. D. ;
Smith, A. A. ;
Houschyar, K. S. ;
Yin, X. ;
Mouraret, S. ;
Brunski, J. B. ;
Helms, J. A. .
JOURNAL OF DENTAL RESEARCH, 2015, 94 (03) :482-490
[5]   Effects of thread depth, taper shape, and taper length on the mechanical properties of mini-implants [J].
Chang, Jenny Zwei-Chieng ;
Chen, Yi-Jane ;
Tung, Yuan-Yi ;
Chiang, Yu-Ying ;
Lai, Eddie Hsiang-Hua ;
Chen, Weng-Pin ;
Lin, Chun-Pin .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 141 (03) :279-288
[6]   Investigation of silk fibroin nanoparticle-decorated poly(L-lactic acid) composite scaffolds for osteoblast growth and differentiation [J].
Chen, Biao-Qi ;
Kankala, Ranjith Kumar ;
Chen, Ai-Zheng ;
Yang, Ding-Zhu ;
Cheng, Xiao-Xia ;
Jiang, Ni-Na ;
Zhu, Kai ;
Wang, Shi-Bin .
INTERNATIONAL JOURNAL OF NANOMEDICINE, 2017, 12 :1877-1890
[7]   Systematic strontium substitution in hydroxyapatite coatings on titanium via micro-arc treatment and their osteoblast/osteoclast responses [J].
Chung, Chi-Jen ;
Long, Han-Yun .
ACTA BIOMATERIALIA, 2011, 7 (11) :4081-4087
[8]   Mechanical influence of thread pitch on orthodontic mini-implant stability [J].
da Cunha, Amanda Carneiro ;
Ayres de Freitas, Amanda Osorio ;
Marquezan, Mariana ;
Nojima, Lincoln Issamu .
BRAZILIAN ORAL RESEARCH, 2015, 29 (01) :1-6
[9]   Parathyroid hormone 1-34 enhances titanium implant anchorage in low-density trabecular bone:: A correlative micro-computed tomographic and biomechanical analysis [J].
Gabet, Yankel ;
Mueller, Ralph ;
Levy, Jay ;
Dimarchi, Richard ;
Chorev, Michael ;
Bab, Itai ;
Kohavi, David .
BONE, 2006, 39 (02) :276-282
[10]   Titanium implants with modified surfaces: Meta-analysis of in vivo osteointegration [J].
Gasik, Michael ;
Braem, Annabel ;
Chaudhari, Amol ;
Duyck, Joke ;
Vleugels, Jozef .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 49 :152-158