Quantitative assessment of disease markers using the naked eye: point-of-care testing with gas generation-based biosensor immunochromatographic strips

被引:16
作者
Fu, Qiangqiang [1 ,2 ,3 ]
Wu, Ze [4 ]
Li, Jingxia [1 ,2 ,3 ]
Wu, Zengfeng [1 ,2 ,3 ]
Zhong, Hui [1 ,2 ,3 ]
Yang, Quanli [1 ,2 ,3 ]
Liu, Qihui [1 ,2 ,3 ]
Liu, Zonghua [1 ,2 ,3 ]
Sheng, Lianghe [1 ,2 ,3 ]
Xu, Meng [1 ,2 ,3 ]
Li, Tingting [4 ]
Yin, Zhinan [1 ,2 ,3 ]
Wu, Yangzhe [1 ,2 ,3 ]
机构
[1] Jinan Univ, Affiliated Hosp 1, Biomed Translat Res Inst, Guangzhou 510632, Guangdong, Peoples R China
[2] Jinan Univ, Sch Pharm, Guangzhou 510632, Guangdong, Peoples R China
[3] Jinan Univ, Guangdong Prov Key Lab Mol Immunol & Antibody Eng, Guangzhou 510632, Guangdong, Peoples R China
[4] Southern Med Univ, Sch Lab Med & Biotechnol, Dept Transfus Med, Guangzhou 510632, Guangdong, Peoples R China
基金
中国博士后科学基金;
关键词
Immunochromatographic strips; Gas generation-based biosensors; C-reactive protein; Au@Pt core; shell nanoparticles; C-REACTIVE PROTEIN; READOUT; SENSOR; QUANTIFICATION; NANOPARTICLES; IMMUNOASSAYS; SENSITIVITY; ASSAY; CHIP;
D O I
10.1186/s12951-019-0493-z
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
BackgroundImmunochromatographic strips (ICSs) are a practical tool commonly used in point-of-care testing (POCT) applications. However, ICSs that are currently available have low sensitivity and require expensive equipment for quantitative analysis. These limitations prohibit their extensive use in areas where medical resources are scarce.MethodsWe developed a novel POCT platform by integrating a gas generation biosensor with Au@Pt Core/Shell nanoparticle (Au@PtNPs)-based ICSs (G-ICSs). The resulting G-ICSs enabled the convenient and quantitative assessment of a target protein using the naked eye, without the need for auxiliary equipment or complicated computation. To assess this platform, C-reactive protein (CRP), a biomarker commonly used for the diagnosis of acute, infectious diseases was chosen as a proof-of-concept test.ResultsThe linear detection range (LDR) of the G-ICSs for CRP was 0.05-6.25g/L with a limit of detection (LOD) of 0.041g/L. The G-ICSs had higher sensitivity and wider LDR when compared with commonly used AuNPs and fluorescent-based ICSs. When compared with results from a chemiluminescent immunoassay, G-ICS concordance rates for CRP detection in serum samples ranged from 93.72 to 110.99%.ConclusionsThese results demonstrated that G-ICSs have wide applicability in family diagnosis and community medical institutions, especially in areas with poor medical resources.
引用
收藏
页数:10
相关论文
共 31 条
[1]   Prospective study of C-reactive protein, homocysteine, and plasma lipid levels as predictors of sudden cardiac death [J].
Albert, CM ;
Ma, J ;
Rifai, N ;
Stampfer, MJ ;
Ridker, PM .
CIRCULATION, 2002, 105 (22) :2595-2599
[2]   Lateral flow assays: Principles, designs and labels [J].
Bahadir, Elif Burcu ;
Sezginturk, Mustafa Kemal .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 82 :286-306
[3]   Integrated Lateral Flow Test Strip with Electrochemical Sensor for Quantification of Phosphorylated Cholinesterase: Biomarker of Exposure to Organophosphorus Agents [J].
Du, Dan ;
Wang, Jun ;
Wang, Limin ;
Lu, Donglai ;
Lin, Yuehe .
ANALYTICAL CHEMISTRY, 2012, 84 (03) :1380-1385
[4]   Lateral Flow Immunoassays - from Paper Strip to Smartphone Technology [J].
Eltzov, Evgeni ;
Guttel, Sarah ;
Kei, Adarina Low Yuen ;
Sinawang, Prima Dewi ;
Ionescu, Rodica E. ;
Marks, Robert S. .
ELECTROANALYSIS, 2015, 27 (09) :2116-2130
[5]   Versatile Barometer Biosensor Based on Au@Pt Core/Shell Nanoparticle Probe [J].
Fu, Qiangqiang ;
Wu, Ze ;
Du, Dan ;
Zhu, Chengzhou ;
Lin, Yuehe ;
Tang, Yong .
ACS SENSORS, 2017, 2 (06) :789-795
[6]   Rough surface Au@Ag core-shell nanoparticles to fabricating high sensitivity SERS immunochromatographic sensors [J].
Fu, Qiangqiang ;
Liu, Hongwu Liu ;
Wu, Ze ;
Liu, An ;
Yao, Cuize ;
Li, Xiuqing ;
Xiao, Wei ;
Yu, Shiting ;
Luo, Zhi ;
Tang, Yong .
JOURNAL OF NANOBIOTECHNOLOGY, 2015, 13
[7]   A novel fluorescence-quenching immunochromatographic sensor for detection of the heavy metal chromium [J].
Fu, QiangQiang ;
Tang, Yong ;
Shi, CongYing ;
Zhang, XiaoLi ;
Xiang, JunJian ;
Liu, Xi .
BIOSENSORS & BIOELECTRONICS, 2013, 49 :399-402
[8]   Platinum-Decorated Gold Nanoparticles with Dual Functionalities for Ultrasensitive Colorimetric in Vitro Diagnostics [J].
Gao, Zhuangqiang ;
Ye, Haihang ;
Tang, Dianyong ;
Tao, Jing ;
Habibi, Sanaz ;
Minerick, Adrienne ;
Tang, Dianping ;
Xia, Xiaohu .
NANO LETTERS, 2017, 17 (09) :5572-5579
[9]   Nanomaterial-enhanced paper-based biosensors [J].
Ge, Xiaoxiao ;
Asiri, Abdullah Mohamed ;
Du, Dan ;
Wen, Wei ;
Wang, Shengfu ;
Lin, Yuehe .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 58 :31-39
[10]   Membrane-based lateral flow immunochromatographic strip with nanoparticles as reporters for detection: A review [J].
Huang, Xiaolin ;
Aguilar, Zoraida P. ;
Xu, Hengyi ;
Lai, Weihua ;
Xiong, Yonghua .
BIOSENSORS & BIOELECTRONICS, 2016, 75 :166-180