The effect of a metal hip prosthesis on the radiation dose in therapeutic photon beam irradiations

被引:30
作者
Lin, SY
Chu, TC
Lin, JP
Liu, MT
机构
[1] Natl Tsing Hua Univ, Dept Nucl Sci 101, Hsinchu 300, Taiwan
[2] Changhua Christian Hosp, Dept Radiat Oncol, Changhua 500, Taiwan
关键词
Monte Carlo; convolution superposition algorithm;
D O I
10.1016/S0969-8043(02)00078-7
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Prostate and cervical cancer patients are often treated with external X-ray beams of bi-lateral incidence. Such treatment may incur some dose effect that cannot be predicted precisely in commercial treatment planning systems (TPS) for patients having undergone total hip replacement. This study performs a Monte Carlo (MC) simulation and an analytical calculation (convolution superposition algorithm which is implemented in ADAC TPS) of a 6 MV, 5 x 5 cm(2) X-ray beam incident into water with the existence of hip prosthesis, e,g. Ti6Al4V and CoCrMo alloy. The results indicate that ADAC TPS cannot precisely account for the scatter and backscatter radiation that a metal hip prosthesis causes. For percent depth dose (PDD) curves, the maximum underdosage of ADAC TPS up to 5 mm above the interface between dense material and water is 5%, 20% and 27% for PDDBone, PDDTi and PDDCo, respectively. The dose re-buildup, which occurs behind the hip region, becomes more and more obvious for denser medium existed in water. Increasing inhomogeneity also enhances the underdosage of ADAC for greater depth (> 10 cm), as the figures of nearly 2% in PDDBone, PDDTi and 4-5% in PDDCo reveal. Overestimating the attenuated power of high-density non-water material in ADAC TPS causes this underdosage. For dose profiles, no significant differences were found in Profile(Bone) at any depth. Profile(Ti) reveals that MC slightly exceeds ADAC at off-axis position 1.0-2.0 cm. Profile(Co) reveals this more obviously. This finding means that scatter radiation from these denser materials is significant and cannot be predicted precisely in ADAC. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:17 / 23
页数:7
相关论文
共 12 条
[1]   CALCULATION AND APPLICATION OF POINT SPREAD FUNCTIONS FOR TREATMENT PLANNING WITH HIGH-ENERGY PHOTON BEAMS [J].
AHNESJO, A ;
ANDREO, P ;
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (01) :49-56
[2]  
*ASM, 1984, ANN BOOK ASTM STAND, P10
[3]  
ATTIX FH, 1986, INTRO RADIOLOGICAL P, P532
[4]  
BIELAJEW AF, 1987, NUCL INSTRUM METH B, V18, P165
[5]   IMPROVED LUNG DOSE CALCULATION USING TISSUE MAXIMUM RATIOS IN THE BATHO CORRECTION [J].
ELKHATIB, E ;
BATTISTA, JJ .
MEDICAL PHYSICS, 1984, 11 (03) :279-286
[6]   Simple beam models for Monte Carlo photon beam dose calculations in radiotherapy [J].
Fix, MK ;
Keller, H ;
Rüegsegger, P ;
Born, EJ .
MEDICAL PHYSICS, 2000, 27 (12) :2739-2747
[7]  
KHAN FM, 1998, TREATMENT PLANNING R, P369
[8]   Monte Carlo simulation of a clinical linear accelerator [J].
Lin, SY ;
Chu, TC ;
Lin, JP .
APPLIED RADIATION AND ISOTOPES, 2001, 55 (06) :759-765
[9]   A CONVOLUTION METHOD OF CALCULATING DOSE FOR 15-MV X-RAYS [J].
MACKIE, TR ;
SCRIMGER, JW ;
BATTISTA, JJ .
MEDICAL PHYSICS, 1985, 12 (02) :188-196
[10]   INVESTIGATION OF THE CONVOLUTION METHOD FOR POLYENERGETIC SPECTRA [J].
PAPANIKOLAOU, N ;
MACKIE, TR ;
MEGERWELLS, C ;
GEHRING, M ;
RECKWERDT, P .
MEDICAL PHYSICS, 1993, 20 (05) :1327-1336