Experience with use of multiplane transesophageal echocardiography to guide closure of atrial septal defects using the Amplatzer device

被引:10
|
作者
Figueroa, MI [1 ]
Balaguru, D [1 ]
McClure, C [1 ]
Kline, CH [1 ]
Radtke, NAK [1 ]
Shirali, GS [1 ]
机构
[1] S Carolina Childrens Heart Ctr, Charleston, SC 29425 USA
关键词
atrial septal defect; transesophageal echocardiography; device closure;
D O I
10.1007/s00246-002-1510-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
By providing unlimited imaging planes, multiplane transesophageal echocardiography (MTEE) should improve real-time guidance of interventional procedures. The potential advantages of MTEE in this scenario have not been systematically evaluated. We retrospectively reviewed our experience with MTEE-guided Amplatzer device closure of atrial septal defects (ASDs) MTEE angles used to obtain images for guiding all measurements and maneuvers were recorded. These angles were compared to the range of MTEE angles that are Postulated to be available from biplane TEE. Images obtained using MTEE angles from 21degrees to 70degrees and from 111degrees to 159degrees were defined as only obtainable by MTEE. The MTEE probe was successfully introduced in all (89) patients. Thirteen patients (15%) had multiple defects. Ninety-five devices (5-32 mm in diameter) were deployed. In 66% of patients, balloon sizing and device deployment necessitated imaging planes that are only obtainable by MTEE, All devices were well positioned. with no impingement on inflows or outflows. At follow-up. 79 of 89 (88.7%) patients had no residual ASDs. Each of the remaining 10 patients (11.3%) had a small (<3 mm) residual defect. MTEE played an important role in guiding device closure of ASD, particularly during the phases of balloon sizing land device deployment.
引用
收藏
页码:430 / 436
页数:7
相关论文
共 50 条
  • [21] The Amplatzer® Septal Occluder, a transcatheter device for atrial septal defect closure
    Fu, Yun-Ching
    Hijazi, Ziyad M.
    EXPERT REVIEW OF MEDICAL DEVICES, 2008, 5 (01) : 25 - 31
  • [22] Early clinical experience with use of the 'Amplatzer Septal Occluder' device for atrial septal defect
    Wilkinson, JL
    Goh, TH
    CARDIOLOGY IN THE YOUNG, 1998, 8 (03) : 295 - 302
  • [23] A comparison of intracardiac echocardiography and transesophageal echocardiography for guiding device closure of ostium secundum atrial septal defect: A 15-year experience
    De Cillis, Emanuela
    Acquaviva, Tommaso
    Ursi, Raffaella
    Soldato, Nicolo
    Basile, Paolo
    Siena, Paola
    Carella, Maria Cristina
    Baggiano, Andrea
    Mushtaq, Saima
    Fusini, Laura
    Rabbat, Mark G.
    Pontone, Gianluca
    Bottio, Tomaso
    Bortone, Alessandro Santo
    Ciccone, Marco Matteo
    Milano, Aldo Domenico
    Guaricci, Andrea Igoren
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2024, 41 (01):
  • [24] Transcatheter Closure of Large Secundum Atrial Septal Defects Using Amplatzer Septal Occlude in Adult
    Permatasari, I. G. A. Wijayanty
    Jaya, I. Pt Parwata
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2019, 21 (0F) : F157 - F158
  • [25] Comparison of transesophageal and intracardiac echocardiography in guiding percutaneous left atrial appendage closure with an Amplatzer Amulet device
    Streb, Witold
    Mitrega, Katarzyna
    Podolecki, Tomasz
    Morawski, Stanislaw
    Szulik, Mariola
    Jedrzejczyk-Patej, Ewa
    Kukulski, Tomasz
    Kalarus, Zbigniew
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2019, 15 (04): : 446 - 454
  • [26] Transcatheter Closure of a Traumatic Ventricular Septal Defect Using an Amplatzer™ Atrial Septal Occluder Device
    Ali, Taimur A.
    Fatimi, Saulat H.
    Hasan, Babar S.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (04) : 569 - 573
  • [27] Appropriate device selection for transcatheter atrial septal defect closure using three-dimensional transesophageal echocardiography
    Hiroki Kitakata
    Yuji Itabashi
    Hideaki Kanazawa
    Kotaro Miura
    Mai Kimura
    Keitaro Shinada
    Marjolein C. de Jongh
    Jin Endo
    Hikaru Tsuruta
    Mitsushige Murata
    Akio Kawamura
    Mitsuru Murata
    Keiichi Fukuda
    The International Journal of Cardiovascular Imaging, 2021, 37 : 1159 - 1168
  • [28] Transthoracic closure of ventricular septal defects guided by transesophageal echocardiography
    Sun Kai-Peng
    Ning, Xu
    Hang Gui-Can
    Huang Jiang-Shan
    Qiang, Chen
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2020, 28 (02): : 250 - 256
  • [29] Appropriate device selection for transcatheter atrial septal defect closure using three-dimensional transesophageal echocardiography
    Kitakata, Hiroki
    Itabashi, Yuji
    Kanazawa, Hideaki
    Miura, Kotaro
    Kimura, Mai
    Shinada, Keitaro
    de Jongh, Marjolein C.
    Endo, Jin
    Tsuruta, Hikaru
    Murata, Mitsushige
    Kawamura, Akio
    Murata, Mitsuru
    Fukuda, Keiichi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (04) : 1159 - 1168
  • [30] Percutaneous closure of postoperative ventricular septal defects with the amplatzer device
    Walsh, MA
    Coleman, DM
    Oslizlok, P
    Walsh, KP
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 67 (03) : 445 - 451