Linear and Volume Measurements of Pulmonary Nodules at Different CT Dose Levels - Intrascan and Interscan Analysis

被引:47
作者
Hein, P. A. [1 ]
Romano, V. C. [1 ]
Rogalla, P. [1 ]
Klessen, C. [1 ]
Lembcke, A. [1 ]
Dickenz, V.
Bornemannz, L.
Bauknecht, H. -C. [1 ]
机构
[1] Charite, Charite Campus Mitte, Inst Radiol, D-10117 Berlin, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2009年 / 181卷 / 01期
关键词
thorax; CT; neoplasms; segmentation; EARLY LUNG-CANCER; THORACIC CT; INTEROBSERVER VARIABILITY; TUMOR RESPONSE; SPIRAL CT; REPRODUCIBILITY; SEGMENTATION; ACCURACY; PERFORMANCE; PROTOCOLS;
D O I
10.1055/s-2008-1027874
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the interobserver variability of the unidimensional diameter and volume measurements of pulmonary nodules in an intrascan and interscan analysis using semi-automated segmentation software on ultra-low-dose computed tomography (ULD-CT) and standard dose CT (SD-CT) data. Materials and Methods: In 33 patients with pulmonary nodules, two chest multi-slice CT (MSCT) datasets (1 mm slice thickness; 20% reconstruction overlap) had been consecutively acquired with an ultra-low dose (120 kV, 5 mAs) and standard dose technique (120 kV, 75 mAs). MSCT data was retrospectively analyzed using the segmentation software OncoTREAT (MeVis, Bremen, Germany, version 1.3). The volume of 229 solid pulmonary nodules included in the analysis as well as the largest diameter according to RECIST (Response Evaluation Criteria for Solid Tumors) were measured by two radiologists. Interobserver variability was calculated and SD-CT and ULD-CT data compared in an intrascan and interscan analysis. Results: The median nodule diameter (n=229 nodules) was registered with 8.2 mm (range: 2.8 to 43.6 mm, mean: 10.8 mm). The nodule volume ranged between 0.01 and 49.1 ml (median 0.1 ml, mean 1.5 ml). With respect to interobserver variability, the intrascan analysis did not reveal statistically significant differences (p>0.05) between ULD-CT and SD-CT with broader limits of agreement for relative differences of RECIST measurements (-31.0% +27.0% mean -2.0% for SD-CT; -27.0% +38.6%, mean 5.8% for ULD-CT) than for volume measurements (-9.4%, 8.0%, mean 0.7% for SD-CT; -13%, 13%, mean 0.0% for ULD-CT). The interscan analysis showed broadened 95% confidence intervals for volume measurements (-26.5% 29.1% mean 1.3%, and -25.2%, 29.6%, mean 2.2%) but yielded comparable limits of agreement for RECIST measurements. Conclusion: The variability of nodule volumetry assessed by semi-automated segmentation software as well as nodule size determination by RECIST appears to be independent of the acquisition dose in the CT source dataset. This is particularly important regarding size determination of pulmonary nodules in screening trials using low-dose CT data for follow-up imaging.
引用
收藏
页码:24 / 31
页数:8
相关论文
共 24 条
  • [1] Biederer J, 2008, Rofo, V5, P471
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] Volumetric assessment of pulmonary nodules with ECG-gated MDCT
    Boll, DT
    Gilkeson, RC
    Fleiter, TR
    Blackham, KA
    Duerk, JL
    Lewin, JS
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (05) : 1217 - 1223
  • [4] Computed tomography-based lung nodule volumetry -: Do optimized reconstructions of routine protocols achieve similar accuracy, reproducibility and interobserver variability to that of special volumetry protocols?
    Bolte, H.
    Riedel, C.
    Knoess, N.
    Freitag, S.
    Hoffmann, B.
    Heller, M.
    Biederer, J.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (03): : 276 - 281
  • [5] Informatics in radiology (infoRAD) -: New tools for computer assistance in thoracic CT -: Part 2.: Therapy monitoring of pulmonary metastases
    Bornemann, L
    Kuhnigk, JM
    Dicken, V
    Zidowitz, S
    Kuemmerlen, B
    Krass, S
    Peitgen, HO
    Wein, BB
    Schubert, H
    Shin, HO
    Wormanns, D
    [J]. RADIOGRAPHICS, 2005, 25 (03) : 841 - 848
  • [6] Automated volumetry of solid pulmonary nodules in a phantom -: Accuracy across different CT scanner technologies
    Das, Marco
    Muehlenbruch, Georg
    Katoh, Markus
    Bakai, Annemarie
    Salganicoff, Marcos
    Stanzel, Sven
    Mahnken, Andreas H.
    Guenther, Rolf W.
    Wildberger, Joachim E.
    [J]. INVESTIGATIVE RADIOLOGY, 2007, 42 (05) : 297 - 302
  • [7] Screening for early lung cancer with low-dose spiral CT: Prevalence in 817 asymptomatic smokers
    Diederich, S
    Wormanns, D
    Semik, M
    Thomas, M
    Lenzen, H
    Roos, N
    Heindel, W
    [J]. RADIOLOGY, 2002, 222 (03) : 773 - 781
  • [8] Interobserver and intraobserver variability in measurement of non-small-cell carcinoma lung lesions: Implications for assessment of tumor response
    Erasmus, JJ
    Gladish, GW
    Broemeling, L
    Sabloff, BS
    Truong, MT
    Herbst, RS
    Munden, RF
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2003, 21 (13) : 2574 - 2582
  • [9] Pulmonary nodules: Interscan variability of semiautomated volume measurements with multisection CT-influence of inspiration level, nodule size, and segmentation performance
    Gietema, Hester A.
    Schaefer-Prokop, Cornelia M.
    Mali, Willem P. T. M.
    Groenewegen, Gerard
    Prokop, Mathias
    [J]. RADIOLOGY, 2007, 245 (03) : 888 - 894
  • [10] Pulmonary nodules detected at lung cancer screening: Interobserver variability of semiautomated volume measurements
    Gietema, Hester A.
    Wang, Ying
    Xu, Dongming
    van Klaveren, Rob J.
    deKoning, Harry
    Scholten, Ernst
    Verschakelen, Johny
    Kohl, Gerhard
    Oudkerk, Matthijs
    Prokop, Mathias
    [J]. RADIOLOGY, 2006, 241 (01) : 251 - 257