Electromagnetic transient modeling of grounding electrodes buried in frequency dependent soil with variable water content

被引:26
|
作者
Salarieh, Bamdad [1 ,2 ]
De Silva, H. M. Jeewantha [2 ]
Kordi, Behzad [1 ]
机构
[1] Univ Manitoba, Dept Elect & Comp Engn, Winnipeg, MB R3T 5V6, Canada
[2] Manitoba Hydro Int, Winnipeg, MB R3P 1A3, Canada
关键词
Frequency dependence of soil; Power system transients; Grounding system; Lightning protection; Water content; Finite element analysis; LIGHTNING RESPONSE; SYSTEMS;
D O I
10.1016/j.epsr.2020.106595
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The increasing demand for electricity over the past few decades has been continuously urging for more reliable power systems. Power transmission line networks, due to their vast physical dimensions, are the most critical components of a complex power system concerning the direct lightning strike. Grounding systems are widely used to mitigate the transient overvoltages for the protection of electrical component and human safety. The goal of this paper is to investigate the effect of frequency dependence of soil electrical parameters on the performance of vertical and horizontal grounding electrodes subjected to direct lightning strike, considering a variable water content of soil. Four soil models that take into account the variation of soil water content are reviewed and compared. The numerical simulations are performed using a full-wave electromagnetic model based on the Finite Element Method (FEM) in the frequency range from 1 kHz to 5 MHz and applying different soil models with varying water content. Then, electromagnetic transient (EMT) compatible equivalent circuits of grounding electrodes are developed using Fast Relaxed Vector Fitting (FRVF). Typical first and subsequent return stroke current waveforms measured at two different locations are adopted. The results of this paper demonstrate the importance of considering the variation of soil water content in the transient response of grounding electrodes. Simulation results demonstrate that the frequency dependence of the soil parameters lead to a decrease of the potential rise of the grounding electrodes compared to the case where the soil parameters are assumed constant. The effect of soil water content on the grounding performance is also shown to be dependent on the soil type, value of soil water content, and length of electrode.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Method of Line for Modeling of Grounding Electrodes Buried in Stratified Multilayer Soil
    Zamani, Hossein
    Sheshyekani, Keyhan
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2022, 64 (06) : 2131 - 2140
  • [2] Transient Responses on Transmission Lines Located Above Frequency-Dependent Soil with Variable Water Content
    Pascoalato, Taina F. G.
    de Araujo, Anderson R. J.
    Kurokawa, Sergio
    Pissolato Filho, Jose
    2021 WORKSHOP ON COMMUNICATION NETWORKS AND POWER SYSTEMS (WCNPS), 2021,
  • [3] Electric fields of grounding electrodes with frequency dependent soil parameters
    Alipio, R. S.
    Schroeder, M. A. O.
    Afonso, M. M.
    Oliveira, T. A. S.
    Assis, S. C.
    ELECTRIC POWER SYSTEMS RESEARCH, 2012, 83 (01) : 220 - 226
  • [4] Computation of ground potential rise and grounding impedance of simple arrangement of electrodes buried in frequency-dependent stratified soil
    de Araujo, Anderson R. J.
    Colqui, Jaimis S. L.
    de Seixas, Claudiner M.
    Kurokawa, Sergio
    Salarieh, Bamdad
    Pissolato Filho, Jose
    Kordi, Behzad
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 198
  • [5] Transient analysis of grounding electrodes in a two-layer soil considering frequency dependence of soil
    Mehri, Ali
    Ghanizadeh, Reza
    Beiraghi, Mojtaba
    ELECTRICAL ENGINEERING, 2022, 104 (02) : 1019 - 1028
  • [6] Transient analysis of grounding electrodes in a two-layer soil considering frequency dependence of soil
    Ali Mehri
    Reza Ghanizadeh
    Mojtaba Beiraghi
    Electrical Engineering, 2022, 104 : 1019 - 1028
  • [7] Comprehensive Modeling of Grounding Electrodes Buried in Ionized Soil Based on MoM-HBM Approach
    Safar, Jalil Ghayur
    Shariatinasab, Reza
    He, Jinliang
    IEEE TRANSACTIONS ON POWER DELIVERY, 2020, 35 (03) : 1390 - 1398
  • [8] Impulse Efficiency of Grounding Electrodes: Effect of Frequency-Dependent Soil Parameters
    Alipio, Rafael
    Visacro, Silverio
    IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (02) : 716 - 723
  • [9] ANALYTICAL MODELING OF GROUNDING ELECTRODES TRANSIENT-BEHAVIOR
    VELAZQUEZ, R
    MUKHEDKAR, D
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (06): : 1314 - 1322
  • [10] Modeling of a buried conductor for an electromagnetic transient simulation
    Ametani, Akihiro
    Soyama, Daigo
    Ishibashi, Yu
    Nagaoka, Naoto
    Okabe, Shigemitsu
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2006, 1 (01) : 45 - 55