3-(2-Bromoacetamido)-N-(9-ethyl-9H)-carbazol fluorescent probe and its application for the determination of thiophenols in rubber products by HPLC with fluorescence detection and atmospheric chemical ionization mass spectrometry identification

被引:10
作者
You, Jinmao [1 ,2 ]
Dou, Kun [1 ]
Song, Cuihua [1 ]
Li, Guoliang [1 ]
Sun, Zhiwei [1 ]
Zhang, Shijuan [1 ]
Chen, Guang [1 ]
Zhao, Xianen [1 ]
Hu, Na [2 ]
Zhou, Wu [3 ]
机构
[1] Qufu Normal Univ, Key Lab Life Organ Anal, Qufu, Shandong, Peoples R China
[2] Chinese Acad Sci, Northwest Inst Plateau Biol, Key Lab Tibetan Med Res, Xining, Peoples R China
[3] Qinghai Univ, State Key Lab Plateau Ecol & Agr, Xining, Peoples R China
基金
中国国家自然科学基金;
关键词
fluorescence detection; high-performance liquid chromatography; rubber; thiophenols; PERFORMANCE LIQUID-CHROMATOGRAPHY; THIOL-CONTAINING COMPOUNDS; LIVING CELLS; WATER SAMPLES; SENSITIVE DETECTION; BIOLOGICAL SAMPLES; HUMAN PLASMA; CYSTEINE; HOMOCYSTEINE; GLUTATHIONE;
D O I
10.1002/jssc.201601166
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid, sensitive, and selective precolumn derivatization method for the simultaneous determination of eight thiophenols using 3-(2-bromoacetamido)-N-(9-ethyl-9H)-carbazol as a labeling reagent by high-performance liquid chromatography with fluorescence detection has been developed. The labeling reagent reacted with thiophenols at 50 degrees C for 50 min in aqueous acetonitrile in the presence of borate buffer (0.10mol/L, pH 11.2) to give high yields of thiophenol derivatives. The derivatives were identified by online postcolumn mass spectrometry. The collision-induced dissociation spectra for thiophenol derivatives gave the corresponding specific fragment ions at m/z 251.3, 223.3, 210.9, 195.8, and 181.9. At the same time, derivatives exhibited intense fluorescence with an excitation maximum at. ex = 276 nm and an emission maximum at lambda(em) = 385 nm. Excellent linear responses were observed for all analytes over the range of 0.033-6.66 mu mol/L with correlation coefficients of more than 0.9997. Detection limits were in the range of 0.94-5.77 mu g/L with relative standard deviations of less than 4.54%. The feasibility of derivatization allowed the development of a rapid and highly sensitive method for the quantitative analysis of trace levels of thiophenols from some rubber products. The average recoveries (n = 3) were in the range of 87.21-101.12%.
引用
收藏
页码:2528 / 2540
页数:13
相关论文
共 47 条
  • [1] A specific HPLC-UV method for the determination of cysteine and related aminothiols in biological samples
    Amarnath, K
    Amarnath, V
    Amarnath, K
    Valentine, HL
    Valentine, WM
    [J]. TALANTA, 2003, 60 (06) : 1229 - 1238
  • [2] TOXICITY OF AROMATIC THIOLS IN THE HUMAN RED BLOOD-CELL
    AMROLIA, P
    SULLIVAN, SG
    STERN, A
    MUNDAY, R
    [J]. JOURNAL OF APPLIED TOXICOLOGY, 1989, 9 (02) : 113 - 118
  • [3] Selective enrichment of sulfides, thiols and methylthiophosphates from water samples on metal-loaded cation-exchange materials for gas chromatographic analysis
    Beiner, K
    Popp, P
    Wennrich, R
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 968 (1-2) : 171 - 176
  • [4] Magnetic graphene oxide-supported hemin as peroxidase probe for sensitive detection of thiols in extracts of cancer cells
    Bi, Sai
    Zhao, Tingting
    Jia, Xiaoqiang
    He, Peng
    [J]. BIOSENSORS & BIOELECTRONICS, 2014, 57 : 110 - 116
  • [5] Gas chromatographic-mass spectrometric analysis of stable isotopes of cysteine and glutathione in biological samples
    Capitan, P
    Malmezat, T
    Breuillé, D
    Obled, C
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 732 (01): : 127 - 135
  • [6] Bromide-sulfur interchange: Ion chromatographic determination of total reduced thiol levels in plasma
    Chitre, Sneha A.
    Lobo, Grace-Ann M.
    Rathod, Spandan M.
    Smith, Robert B.
    Leslie, Ray
    Livingstone, Callum
    Davis, James
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 864 (1-2): : 173 - 177
  • [7] A trinuclear heterobimetallic Ru(II)/Pt(II) complex as a chemodosimeter selective for sulfhydryl-containing amino acids and peptides
    Chow, CF
    Chiu, BKW
    Lam, MHW
    Wong, WY
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (26) : 7802 - 7803
  • [8] A simple and effective coumarin-based fluorescent probe for cysteine
    Dai, Xi
    Wu, Qing-Hua
    Wang, Peng-Chong
    Tian, Jie
    Xu, Yu
    Wang, Sheng-Qing
    Miao, Jun-Ying
    Zhao, Bao-Xiang
    [J]. BIOSENSORS & BIOELECTRONICS, 2014, 59 : 35 - 39
  • [9] Characterization of liquid products from pyrolysis of subbituminous coals
    Ekinci, E
    Yardim, F
    Razvigorova, M
    Minkova, V
    Goranova, M
    Petrov, N
    Budinova, T
    [J]. FUEL PROCESSING TECHNOLOGY, 2002, 77 : 309 - 315
  • [10] Simultaneous analysis of plasma thiols by high-performance liquid chromatography with fluorescence detection using a new probe, 1,3,5,7-tetramethyl-8-phenyl-(4-iodoacetamido)difluoroboradiaza-s-indacene
    Guo, Xiao-Feng
    Wang, Hong
    Guo, Yue-Hong
    Zhang, Zi-Xing
    Zhang, Hua-Shan
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (18) : 3874 - 3880