Strains Around Abutment Teeth with Different Attachments Used for Implant-Assisted Distal Extension Partial Overdentures: An In Vitro Study

被引:15
作者
ELsyad, Moustafa Abdou [1 ]
Omran, Abdelbaset Omar [2 ]
Fouad, Mohammed Mohammed [1 ]
机构
[1] Univ Mansoura, Dept Removable Prosthodont, Fac Dent, POB 35516,68 EL Gomhoria St, Mansoura, El Dakahlia, Egypt
[2] Univ Mansoura, Fac Dent, Mansoura, El Dakahlia, Egypt
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2017年 / 26卷 / 01期
关键词
Strain; abutment; attachments; implant; distal extension RPD; REMOVABLE PARTIAL DENTURES; SHORTENED DENTAL ARCHES; OSSEOINTEGRATED IMPLANTS; STRESS-DISTRIBUTION; GAUGE MEASUREMENTS; LOAD-TRANSFER; ORAL FUNCTION; RETENTION; LOCATION; SUPPORT;
D O I
10.1111/jopr.12370
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeThe aim of this study was to evaluate and compare strain around abutment teeth with different attachments used for implant-assisted distal extension partial overdentures (IADEPODs). Materials and MethodsA mandibular Kennedy class I acrylic model (remaining teeth from first premolar to first premolar) was constructed. A conventional partial denture was constructed over the model (control, group 1). Two laboratory implants were then placed bilaterally in the first molar areas parallel to each other and perpendicular to the residual ridge. Three additional experimental partial overdentures (PODs) were constructed and connected to the implants using ball (group 2), magnetic (group 3), and Locator (group 4) attachments. Three linear strain gauges were bonded buccal, lingual, and distal to the first premolar abutment tooth at the right (loading) and the left (nonloading) sides. For each group, a universal testing device was used to apply a unilateral vertical static load (50 N) on the first molar area, and the strain was recorded using a multichannel digital strainometer. ResultsSignificant differences between groups and between sites of strain gauges were detected. Strains recorded for all groups were compressive (negative) in nature. Group 1 demonstrated the highest strain, followed by group 3 and group 4; group 2 recorded the lowest strain. For group 2, the highest strain was recoded at the lingual nonloading side. For group 1, group 3, and group 4, the highest strain was recorded at the buccal loading side. ConclusionWithin the limitation of the present study, ball attachments used to retain IADEPODs to the implants were associated with lower strains around abutment teeth than Locator and magnetic attachments. The highest strain was recorded with conventional partial dentures.
引用
收藏
页码:42 / 47
页数:6
相关论文
共 39 条
[1]  
Akça K, 2002, INT J PROSTHODONT, V15, P115
[2]   Effects of prosthesis design and impression techniques on human cortical bone strain around oral implants under load [J].
Akca, Kivanc ;
Kokat, Ali Murat ;
Sahin, Saime ;
Iplikcioglu, Haldun ;
Cehreli, Murat Cavit .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (07) :758-763
[3]   A strain gauge and photoelastic analysis of in vivo strain and in vitro stress distribution in human dental supporting structures [J].
Asundi, A ;
Kishen, A .
ARCHIVES OF ORAL BIOLOGY, 2000, 45 (07) :543-550
[4]  
Brudvik J S., 1999, Advanced removable partial dentures, P153
[5]  
Cehreli Murat C, 2002, Implant Dent, V11, P286
[6]  
Çekiç C, 2007, QUINTESSENCE INT, V38, pE291
[7]   Effect of splinting on load distribution of extracoronal attachment with distal extension prosthesis in vitro [J].
ElCharkawi, HG ;
ElWakad, MT .
JOURNAL OF PROSTHETIC DENTISTRY, 1996, 76 (03) :315-320
[8]   STRESS-ANALYSIS OF DIFFERENT OSSEOINTEGRATED IMPLANTS SUPPORTING A DISTAL-EXTENSION PROSTHESIS [J].
ELCHARKAWI, HG ;
ZEKRY, KA ;
ELWAKAD, MT .
JOURNAL OF PROSTHETIC DENTISTRY, 1994, 72 (06) :614-622
[9]   Effect of Dislodging Forces on Mandibular Implant Attachment-Retained Overdenture [J].
ElKerdawy, Maha Wagdy ;
Radi, Iman Abdel Wahab .
IMPLANT DENTISTRY, 2011, 20 (03) :246-+
[10]   Effect of different implant positions on strain developed around four implants supporting a mandibular overdenture with rigid telescopic copings [J].
ELsyad, Moustafa Abdou ;
Elsaadawy, Maged Gaber ;
Abdou, Anwar Mahmoud ;
Habib, Ahmed Ali .
QUINTESSENCE INTERNATIONAL, 2013, 44 (09) :679-686