Cellular dosimetry calculations for Strontium-90 using Monte Carlo code PENELOPE

被引:3
作者
Hocine, Nora [1 ]
Farlay, Delphine [2 ,3 ]
Boivin, Georges [2 ,3 ]
Franck, Didier [1 ]
Agarande, Michelle [1 ]
机构
[1] Inst Radioprotect & Surete Nucl, Lyon, France
[2] INSERM UMR 1033, Lyon, France
[3] Univ Lyon, Lyon, France
关键词
PENELOPE; MCNPX; MIRD; Sr-90; validation; cellular dosimetry; TRANSPORT; PHOTON;
D O I
10.3109/09553002.2014.955144
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: To improve risk assessments associated with chronic exposure to Strontium-90 (Sr-90), for both the environment and human health, it is necessary to know the energy distribution in specific cells or tissue. Monte Carlo (MC) simulation codes are extremely useful tools for calculating deposition energy. The present work was focused on the validation of the MC code PENetration and Energy LOss of Positrons and Electrons (PENELOPE) and the assessment of dose distribution to bone marrow cells from punctual Sr-90 source localized within the cortical bone part. Materials and methods: S-values (absorbed dose per unit cumulated activity) calculations using Monte Carlo simulations were performed by using PENELOPE and Monte Carlo N-Particle eXtended (MCNPX). Cytoplasm, nucleus, cell surface, mouse femur bone and Sr-90 radiation source were simulated. Cells are assumed to be spherical with the radii of the cell and cell nucleus ranging from 2-10 mm. The Sr-90 source is assumed to be uniformly distributed in cell nucleus, cytoplasm and cell surface. Results: The comparison of S-values calculated with PENELOPE to MCNPX results and the Medical Internal Radiation Dose (MIRD) values agreed very well since the relative deviations were less than 4.5%. The dose distribution to mouse bone marrow cells showed that the cells localized near the cortical part received the maximum dose. Conclusion: The MC code PENELOPE may prove useful for cellular dosimetry involving radiation transport through materials other than water, or for complex distributions of radionuclides and geometries.
引用
收藏
页码:953 / 958
页数:6
相关论文
共 12 条
  • [1] [Anonymous], 2000, AGENCY TOXIC SUBSTAN
  • [2] Capacity of 1,25-dihydroxyvitamin D to stimulate expression of calbindin D changes with age in the rat
    Armbrecht, HJ
    Boltz, MA
    Christakos, S
    Bruns, MEH
    [J]. ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1998, 352 (02) : 159 - 164
  • [3] In osteoporotic women treated with strontium ranelate, strontium is located in bone formed during treatment with a maintained degree of mineralization
    Boivin, G.
    Farlay, D.
    Khebbab, M. T.
    Jaurand, X.
    Delmas, P. D.
    Meunier, P. J.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2010, 21 (04) : 667 - 677
  • [4] Boivin G., 2010, INT BONE MINERAL SOC, V7, P103
  • [5] Distribution of strontium and mineralization in iliac bone biopsies from osteoporotic women treated long-term with strontium ranelate
    Doublier, Audrey
    Farlay, Delphine
    Khebbab, Mohamed T.
    Jaurand, Xavier
    Meunier, Pierre J.
    Boivin, Georges
    [J]. EUROPEAN JOURNAL OF ENDOCRINOLOGY, 2011, 165 (03) : 469 - 476
  • [6] Goddu SM., 1997, MIRD CELLULAR S VALU
  • [7] Cellular dosimetry of strontium-90 using the Monte Carlo code MCNPX, detection and X-ray microanalysis
    Hocine, N.
    Farlay, D.
    Bertho, J. -M.
    Boivin, G.
    Desbree, A.
    Franck, D.
    Agarande, M.
    [J]. RADIOPROTECTION, 2014, 49 (02) : 101 - 105
  • [8] Pelowitz DB, 2005, 050369 LACP
  • [9] SALVAT F, 1996, 799 CIEMAT
  • [10] Overview of physical interaction models for photon and electron transport used in Monte Carlo codes
    Salvat, Francesc
    Fernandez-Varea, Jose M.
    [J]. METROLOGIA, 2009, 46 (02) : S112 - S138