A biological phantom for evaluation of CT image reconstruction algorithms

被引:0
作者
Cammin, J. [1 ]
Fung, G. S. K. [1 ]
Fishman, E. K. [1 ]
Siewerdsen, J. H. [2 ]
Stayman, J. W. [2 ]
Taguchi, K. [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD USA
来源
MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING | 2014年 / 9033卷
基金
美国国家卫生研究院;
关键词
computed tomography; biological phantom; liver lesions; filtered backprojection; iterative reconstruction; edge sharpness; noise power spectrum; image quality; AFFIRMED ITERATIVE RECONSTRUCTION; QUALITY;
D O I
10.1117/12.2043714
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In recent years, iterative algorithms have become popular in diagnostic CT imaging to reduce noise or radiation dose to the patient. The non-linear nature of these algorithms leads to non-linearities in the imaging chain However, the methods to assess the performance of CT imaging systems were developed assuming the linear process of filtered backprojection (FBP). Those methods may not be suitable any longer when applied to non-linear systems. In order to evaluate the imaging performance, a phantom is typically scanned and the image quality is measured using various indices. For reasons of practicality, cost, and durability, those phantoms often consist of simple water containers with uniform cylinder inserts. However, these phantoms do not represent the rich structure and patterns of real tissue accurately. As a result, the measured image quality or detectability performance for lesions may not reflect the performance on clinical images. The discrepancy between estimated and real performance may be even larger for iterative methods which sometimes produce "plastic-like", patchy images with homogeneous patterns. Consequently, more realistic phantoms should be used to assess the performance of iterative algorithms We designed and constructed a biological phantom consisting of porcine organs and tissue that models a human abdomen, including liver lesions. We scanned the phantom on a clinical CT scanner and compared basic image quality indices between filtered backprojection and an iterative reconstruction algorithm.
引用
收藏
页数:8
相关论文
共 11 条
[1]   Robust uncertainty principles:: Exact signal reconstruction from highly incomplete frequency information [J].
Candès, EJ ;
Romberg, J ;
Tao, T .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (02) :489-509
[2]   Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets [J].
Chen, Guang-Hong ;
Tang, Jie ;
Leng, Shuai .
MEDICAL PHYSICS, 2008, 35 (02) :660-663
[3]   Statistical image reconstruction for polyenergetic X-ray computed tomography [J].
Elbakri, IA ;
Fessler, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (02) :89-99
[4]  
Grant K., 2012, SAFIRE: Sinogram affirmed iterative reconstruction
[5]   Assessment of an iterative reconstruction algorithm (SAFIRE) on image quality in pediatric cardiac CT datasets [J].
Han, B. Kelly ;
Grant, Katharine L. R. ;
Garberich, Ross ;
Sedlmair, Martin ;
Lindberg, Jana ;
Lesser, John R. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (03) :200-204
[6]   Radiation Dose Reduction With Sinogram Affirmed Iterative Reconstruction Technique for Abdominal Computed Tomography [J].
Kalra, Mannudeep K. ;
Woisetschlager, Mischa ;
Dahlstrom, Nils ;
Singh, Sarabjeet ;
Lindblom, Maria ;
Choy, Garry ;
Quick, Petter ;
Schmidt, Bernhard ;
Sedlmair, Martin ;
Blake, Michael A. ;
Persson, Anders .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (03) :339-346
[7]  
Sidky EY, 2006, J X-RAY SCI TECHNOL, V14, P119
[8]   Iterative methods for total variation denoising [J].
Vogel, CR ;
Oman, ME .
SIAM JOURNAL ON SCIENTIFIC COMPUTING, 1996, 17 (01) :227-238
[9]   Influence of Sinogram Affirmed Iterative Reconstruction of CT Data on Image Noise Characteristics and Low-Contrast Detectability: An Objective Approach [J].
von Falck, Christian ;
Bratanova, Vesela ;
Rodt, Thomas ;
Meyer, Bernhard ;
Waldeck, Stephan ;
Wacker, Frank ;
Shin, Hoen-oh .
PLOS ONE, 2013, 8 (02)
[10]   Image quality and radiation dose of low dose coronary CT angiography in obese patients: Sinogram affirmed iterative reconstruction versus filtered back projection [J].
Wang, Rui ;
Schoepf, U. Joseph ;
Wu, Runze ;
Reddy, Ryan P. ;
Zhang, Chuanchen ;
Yu, Wei ;
Liu, Yi ;
Zhang, Zhaoqi .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) :3141-3145