Uncertainty reduction due to correlation effects in weighing during the preparation of primary gas standards

被引:18
作者
Milton, MJT [1 ]
Woods, PT [1 ]
Holland, PE [1 ]
机构
[1] Natl Phys Lab, Ctr Opt & Environm Metrol, Teddington TW11 0LW, Middx, England
关键词
D O I
10.1088/0026-1394/39/1/12
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The accurate weighing of gas into high-pressure cylinders plays a central role in providing traceability for primary gas mixtures. The uncertainties in the masses of successive components added to such mixtures are significantly correlated. We show that a consequence is that the amount fraction of the resulting mixture is not influenced by changes in buoyancy due to the linear expansion of the cylinder. This result will provide a useful simplification to some procedures used in gas metrology.
引用
收藏
页码:97 / 99
页数:3
相关论文
共 7 条
[1]   Uncertainty calculations for the preparation of primary gas mixtures - part 1. Gravimetry [J].
Alink, A ;
van der Veen, AMH .
METROLOGIA, 2000, 37 (06) :641-650
[2]  
BESLEY L, COMMUNICATION
[3]  
*INT ORG STAND, 14912 ISO DIS
[4]  
*INT STAND ORG, 2001, 6142 ISO
[5]  
MILTON MJT, 2000, 60 NPL COEM
[6]  
MORLEY A, 1952, STRENGTH MAT
[7]  
SCHWARTZ R, 2000, COMPREHENSIVE MASS M