Use of local pro-coagulant haemostatic agents for intra-cavity control of haemorrhage after trauma

被引:13
作者
Navarro, A. [1 ]
Brooks, A. [1 ]
机构
[1] Univ Nottingham Hosp, NHS Trust & East Midlands Major Trauma Ctr, Hepatobiliary Surg & Major Trauma, Nottingham NG7 2UH, England
关键词
Trauma; Coagulopathy; Haemorrhage; Haemostasis; Haemostatic agents; Fibrin sealants; CONTROLLED CLINICAL-TRIAL; FIBRIN SEALANT; DAMAGE-CONTROL; LIVER RESECTION; RENAL INJURIES; BLOOD-LOSS; EFFICACY; GELATIN; MODEL; DRESSINGS;
D O I
10.1007/s00068-014-0441-4
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Uncontrolled haemorrhage as a result of trauma remains a significant surgical challenge, accounting for approximately 25-40 % of trauma-related mortality. A wide range of local internal haemostatic agents have been developed to help achieve intra-cavity control of bleeding, with choice of agent influenced by the circumstances and nature of the haemorrhage. Trauma patients are frequently coagulopathic, so products that incorporate pro-coagulant technology and thereby act independently of the clotting cascade may be more effective in these settings. A range of products that utilise thrombin and fibrinogen to promote local haemostasis at intra-cavity bleeding points are available or in development, including fibrin glues (e.g. TisseelA (R)/TissucolA (R) A and EvicelA (R)/CrossealA (R)/QuixilA (R)), fibrin sealant patches (e.g. TachoSilA (R)) and products based on a gelatin-thrombin haemostatic matrix (e.g. FloSealA (R)). This systematic review was performed to assess all peer-reviewed evidence of product efficacy. Fibrin sealant patches have shown haemostatic efficacy in a variety of surgical procedures and appear to offer practical advantages over liquid fibrin glues. Existing evidence suggests that patch products enable delivery of pro-coagulants to defined areas with less chance of dilution and/or displacement by blood flow, but they require a pressure buttress for a suitable amount of time to achieve good results after trauma. Our experience, supported by other reports in the literature, suggests the use of such fibrin patches may provide an effective option in helping to control haemorrhage after trauma. However, there is a general paucity of clinical data for intra-cavity haemostatic agent use, with the majority of data being based on animal models and case reports. Further clinical evidence, ideally including comparative studies between different agents, would be beneficial in helping guide surgeon choice to the most appropriate products to use in trauma settings.
引用
收藏
页码:493 / 500
页数:8
相关论文
共 61 条
[31]   Comparative study of the efficacy of the common topical hemostatic agents with fibrin sealant in a rabbit aortic anastomosis model [J].
Kheirabadi, BS ;
Field-Ridley, A ;
Pearson, R ;
MacPhee, M ;
Drohan, W ;
Tuthill, D .
JOURNAL OF SURGICAL RESEARCH, 2002, 106 (01) :99-107
[32]  
Kheirabadi BS, 2004, RTOMPHFM109 NATORAN
[33]   A phase III, randomized, controlled, superiority trial evaluating the fibrin pad versus standard of care in controlling parenchymal bleeding during elective hepatic surgery [J].
Koea, Jonathan B. ;
Batiller, Jonathan ;
Patel, Babahai ;
Shen, Jessica ;
Hammond, Jeffrey ;
Hart, James ;
Fischer, Craig ;
Garden, O. James .
HPB, 2013, 15 (01) :61-70
[34]  
LARSON MJ, 1995, ARCH SURG-CHICAGO, V130, P420
[35]   Damage-control laparotomy [J].
Lee, John C. ;
Peitzman, Andrew B. .
CURRENT OPINION IN CRITICAL CARE, 2006, 12 (04) :346-350
[36]   Gelatin thrombin granules for hemostasis in a severe traumatic liver and spleen rupture model in swine [J].
Leixnering, Martin ;
Reichetseder, Jurgen ;
Schultz, Arthur ;
Figl, Markus ;
Wassermann, Esther ;
Thurnher, Martin ;
Redl, Heinz .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 64 (02) :456-461
[37]   Comparison of Two Gelatin and Thrombin Combination Hemostats in a Porcine Liver Abrasion Model [J].
Lewis, Kevin M. ;
Atlee, Holly D. ;
Mannone, Angela J. ;
Dwyer, Joseph ;
Lin, Lawrence ;
Goppelt, Andreas ;
Redl, Heinz .
JOURNAL OF INVESTIGATIVE SURGERY, 2013, 26 (03) :141-148
[38]   TachoSil surgical patch versus conventional haemostatic fleece material for control of bleeding in cardiovascular surgery: a randomised controlled trial [J].
Maisano, Francesco ;
Kjaergard, Henrik K. ;
Bauernschmitt, Robert ;
Pavie, Alain ;
Rabago, Gregorio ;
Laskar, Marc ;
Marstein, Jens Pauli ;
Falk, Volkmar .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 36 (04) :708-714
[39]   Efficacy and safety of TachoSil® versus standard treatment of air leakage after pulmonary lobectomy [J].
Marta, Gabriel Mihai ;
Facciolo, Francesco ;
Ladegaard, Lars ;
Dienemann, Hendrik ;
Csekeo, Attila ;
Rea, Federico ;
Dango, Sebastian ;
Spaggiari, Lorenzo ;
Tetens, Vilhelm ;
Klepetko, Walter .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2010, 38 (06) :683-689
[40]   Prospective, randomized, controlled clinical trial of a novel matrix hemostatic sealant in patients with acute anterior epistaxis [J].
Mathiasen, RA .
LARYNGOSCOPE, 2005, 115 (05) :899-902