Cryoballoon Ablation in Young Patients With Lone Paroxysmal Atrial Fibrillation

被引:5
|
作者
Wojcik, Maciej [1 ,2 ]
Berkowitsch, Alexander [1 ]
Zaltsberg, Sergey [1 ]
Hamm, Christian W. [1 ,3 ]
Pitschner, Heinz F. [1 ]
Neumann, Thomas [1 ,3 ]
Kuniss, Malte [1 ]
机构
[1] Kerckhoff Heart & Thorax Ctr, Dept Cardiol, D-61231 Bad Nauheim, Germany
[2] Med Univ Lublin, Dept Cardiol, Lublin, Poland
[3] Univ Giessen, Dept Cardiol, D-35390 Giessen, Germany
来源
REVISTA ESPANOLA DE CARDIOLOGIA | 2014年 / 67卷 / 07期
关键词
Atrial fibrillation; Paroxysmal atrial fibrillation; Cryoballoon ablation; Long-term outcome; PULMONARY VEIN ISOLATION; PHRENIC-NERVE PALSY; CATHETER ABLATION; EUROPEAN-SOCIETY; FOLLOW-UP; MANAGEMENT; RHYTHM; PREDICTORS; PREVENTION; GUIDELINES;
D O I
10.1016/j.rec.2013.11.024
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and objectives: Long-term efficacy following cryoballoon ablation of lone paroxysmal atrial fibrillation remains unknown. We describe long-term follow-up results of the single cryoballoon ablation procedure. Methods: Pulmonary vein isolation was performed in 103 patients (72 male; median age 52 years) with symptomatic lone paroxysmal atrial fibrillation. The end-point of this observational cohort study was first electrocardiogram-documented recurrence of arrhythmia (atrial fibrillation, atrial tachycardia, or atrial flutter) during the 5-year follow-up, in the absence of anti-arrhythmic treatment. Results: Acute complete pulmonary vein isolation was achieved in 86% of the patients with a single cryoballoon. The 6-month, 1-year, and 5-year success rate after a single procedure was 94%, 91%, and 77%, respectively. Arrhythmia recurrence was observed in 24 cases at a median of 14.8 months [range, 8.0-16.8 months]. Thirteen symptomatic patients were well controlled on beta-blockers only. Seven symptomatic patients had anti-arrhythmic treatment (class IC in 5 patients; dronedarone in 2 patients) introduced during the blanking period. Two of them had early arrhythmia recurrence within the blanking period only; they were arrhythmia-free in further follow-up on dronedarone. The rate of complications was relatively low and included a 4.8% incidence of transient phrenic nerve palsy. Conclusions: A single cryoballoon ablation procedure for lone paroxysmal atrial fibrillation resulted in high rates of acute, medium-term, and long-term efficacy. The rate of complications is relatively low and includes a 4.8% incidence of transient phrenic nerve palsy. (C) 2013 Sociedad Espanola de Cardiologia. Published by Elsevier Espana, S. L. All rights reserved.
引用
收藏
页码:558 / 563
页数:6
相关论文
共 50 条
  • [1] CRYOBALLOON ABLATION FOR PAROXYSMAL ATRIAL FIBRILLATION
    Guitang, Y.
    Ming, L.
    Zulu, W.
    Yan-chun, L.
    Zhi-qing, J.
    Mingying, D.
    Ya-ling, H.
    HEART, 2015, 101 : A7 - A7
  • [2] Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation
    Kuck, Karl-Heinz
    Brugada, Josep
    Fuernkranz, Alexander
    Metzner, Andreas
    Ouyang, Feifan
    Chun, K. R. Julian
    Elvan, Arif
    Arentz, Thomas
    Bestehorn, Kurt
    Pocock, Stuart J.
    Albenque, Jean-Paul
    Tondo, Claudio
    NEW ENGLAND JOURNAL OF MEDICINE, 2016, 374 (23): : 2235 - 2245
  • [3] Cryoballoon ablation beyond paroxysmal atrial fibrillation
    Rottner, Laura
    Fink, Thomas
    Kuck, Karl-Heinz
    CURRENT OPINION IN CARDIOLOGY, 2019, 34 (01) : 23 - 28
  • [4] Atrial tachycardia after cryoballoon ablation of paroxysmal atrial fibrillation
    Wojcik, Maciej
    Berkowitsch, Alexander
    Pitschner, Heinz F.
    Kuniss, Malte
    Neumann, Thomas
    EUROPACE, 2014, 16 (02): : 306 - 306
  • [5] Cryoballoon versus radiofrequency ablation for paroxysmal atrial fibrillation in hemodialysis patients
    Tomomasa Takamiya
    Junichi Nitta
    Osamu Inaba
    Akira Sato
    Yukihiro Inamura
    Nobutaka Kato
    Kazuya Murata
    Takashi Ikenouchi
    Toshikazu Kono
    Giichi Nitta
    Yutaka Matsumura
    Yoshihide Takahashi
    Masahiko Goya
    Tetsuo Sasano
    Heart and Vessels, 2020, 35 : 1709 - 1716
  • [6] Cryoballoon versus radiofrequency ablation for paroxysmal atrial fibrillation in hemodialysis patients
    Takamiya, Tomomasa
    Nitta, Junichi
    Inaba, Osamu
    Sato, Akira
    Inamura, Yukihiro
    Kato, Nobutaka
    Murata, Kazuya
    Ikenouchi, Takashi
    Kono, Toshikazu
    Nitta, Giichi
    Matsumura, Yutaka
    Takahashi, Yoshihide
    Goya, Masahiko
    Sasano, Tetsuo
    HEART AND VESSELS, 2020, 35 (12) : 1709 - 1716
  • [7] Effect of cryoballoon ablation parameters on recurrence in patients with paroxysmal atrial fibrillation
    Demirtas, Abdullah Orhan
    Icen, Yahya Kemal
    Donmez, Yurdaer
    Koca, Hasan
    Kaypakli, Onur
    Sahin, Durmus Yildiray
    Koc, Mevlut
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2019, 47 (06): : 440 - 448
  • [8] Cryoballoon ablation for pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Kuehne, Michael
    Schaer, Beat
    Ammann, Peter
    Suter, Yves
    Osswald, Stefan
    Sticherling, Christian
    SWISS MEDICAL WEEKLY, 2010, 140 (15-16) : 214 - 221
  • [9] Pulsed Field or Cryoballoon Ablation for Paroxysmal Atrial Fibrillation
    Reichlin, Tobias
    Kueffer, Thomas
    Badertscher, Patrick
    Juni, Peter
    Knecht, Sven
    Thalmann, Gregor
    Kozhuharov, Nikola
    Krisai, Philipp
    Jufer, Corinne
    Maurhofer, Jens
    Heg, Dik
    Pereira, Tiago V.
    Mahfoud, Felix
    Servatius, Helge
    Tanner, Hildegard
    Kuhne, Michael
    Roten, Laurent
    Sticherling, Christian
    SINGLE SHOT CHAMPION Investigators
    NEW ENGLAND JOURNAL OF MEDICINE, 2025,
  • [10] THE IMPACT OF ATRIAL FIBRILLATION BURDEN ON CRYOBALLOON ABLATION OUTCOMES FOR PAROXYSMAL ATRIAL FIBRILLATION
    Bose, Abhishek
    Chevli, Parag Anilkumar
    Hashmath, Zeba
    Mishra, Ajay K.
    Berberian, Gregory
    Ahmad, Ghasan
    Januszkiewicz, Jerzy
    Laidlaw, Douglas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 457 - 457