A new non-contact approach for the measurement and uniformity evaluation of coating thickness for sheet metal

被引:0
作者
Qiu, Zixue [1 ]
Zheng, Tianchi [1 ]
Wan, Liping [1 ]
Lu, Guan [1 ]
Shao, Jianxin [1 ]
Yuan, Jiang [1 ]
机构
[1] Nantong Univ, Sch Mech Engn, Nantong 226019, Jiangsu, Peoples R China
关键词
PROFILE MEASUREMENT; ERRORS;
D O I
10.1063/1.4973668
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
To realize the automatic measurement and uniformity evaluation of the coating thickness for sheet metal, a new non-contact detection method for coating thickness was proposed based on a double laser probe and mechanical servo system. Non-contact measurement of coating thickness can be achieved by differential measurement principle of double laser probe, and the influences of sheet metal's Z position changes and platform's vibration on the measurement results can be removed by this method. A new coating thickness evaluation algorithm by integrating the least squares principle and cubic spline interpolation was given, which can fit the discrete thickness data into visual and accurate 3D graphics; and the measurement accuracy was evaluated based on grey theory, solving the problem of low accuracy by using limited measurement data to evaluate the thickness uniformity of an entire sheet metal. The stability and reliability of the system are verified by experiments, and the measurement results of the specimen show that the measurement uncertainty is 0.016 mu m and the maximum range of the uniformity evaluation result is 1.4 mu m. Published by AIP Publishing.
引用
收藏
页数:8
相关论文
共 25 条
  • [1] Cai C. L., 2002, VAC ELECT, V44, P25
  • [2] Portable x-ray fluorescence spectrometer for coating thickness measurement
    Carapelle, Alain
    Fleury-Frenette, Karl
    Collette, Jean-Paul
    Garnir, Henri-Pierre
    Harlet, Philippe
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (12)
  • [3] A method of vertical and horizontal plus cubic spline interpolation for Mie scattering lidar profile data
    Chen Hao
    Hua Deng-Xin
    Zhang Yi-Kun
    Zhu Cheng-Xuan
    [J]. ACTA PHYSICA SINICA, 2014, 63 (15)
  • [4] Dai H., 2007, VACUUM, V44, P8
  • [5] Self-calibration and Compensation of Setting Errors for Surface Profile Measurement of a Microstructured Roll Workpiece
    Gao Wei
    Xu Bin
    Takeishi, Toshiki
    Shimizu, Yuki
    Ito, So
    [J]. CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2014, 27 (01) : 14 - 22
  • [6] Heat flux sensor calibration using noninteger system identification: Theory, experiment, and error analysis
    Gardarein, Jean-Laurent
    Battaglia, Jean-Luc
    Loehle, Stefan
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (02)
  • [7] Convexity-preserving approximation by univariate cubic splines
    Han, Xuli
    [J]. JOURNAL OF COMPUTATIONAL AND APPLIED MATHEMATICS, 2015, 287 : 196 - 206
  • [8] Optical instrument for measurement of vaginal coating thickness by drug delivery formulations
    Henderson, MH
    Peters, JJ
    Walmer, DK
    Couchman, GM
    Katz, DF
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (03)
  • [9] Polarization-Dependent and Ellipsometric Infrared Microscopy for Analysis of Anisotropic Thin Films
    Hinrichs, Karsten
    Furchner, Andreas
    Rappich, Joerg
    Oates, Thomas W. H.
    [J]. JOURNAL OF PHYSICAL CHEMISTRY C, 2013, 117 (26) : 13557 - 13563
  • [10] [焦敬品 Jiao Jingpin], 2013, [仪器仪表学报, Chinese Journal of Scientific Instrument], V34, P588