Quality of cardiopulmonary resuscitation among highly trained staff in an emergency department setting

被引:56
作者
Losert, Heidrun
Sterz, Fritz
Koehler, Klemens
Sodeck, Gottfried
Fleischhackl, Roman
Eisenburger, Philip
Kliegel, Andreas
Herkner, Harald
Myklebust, Helge
Nysaether, Jon
Laggner, Anton N.
机构
[1] Med Univ Vienna, Dept Emergency Med, A-1090 Vienna, Austria
[2] Laerdal Med, Stavanger, Norway
关键词
D O I
10.1001/archinte.166.21.2375
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Recent reports have highlighted the poor standard of cardiopulmonary resuscitation (CPR) achieved by health care professionals in diverse situations. We explored what can be achieved in an emergency department by highly trained permanent staff. Methods: In a prospective observational study conducted from June 1, 2002, to August 31, 2005, 80 of 213 patients requiring CPR and admitted to the emergency department of a tertiary care hospital were eligible for study participation. Owing to several logistic problems with CPR, 133 patients could not be studied. The CPR team consisted of emergency- and critical care-trained physicians with more than 10 years of acute care experience, most of whom were instructors of European Resuscitation Council courses in basic and advanced life support. A specially designed defibrillator was used to assess the quality of CPR. Results: For 80 patients, 95 data sets were available for analysis, yielding a total of 1065 minutes of cardiac arrest time. Chest compressions were performed at a rate of 114 ( 95% confidence interval [CI], 112-116) per minute, resulting in a mean of 96( 95% CI, 93-99) delivered chest compressions per minute. We further observed a mean hands-off ratio of 12.7%( 95% CI, 12.3%-13.1%), and the hands-off ratio was linearly associated with the duration of CPR(R-2 = 0.95; mean, 4.3% increments per 5-10 minutes; P < .001). Patients were hyperventilated with a median of 18 (interquartile range, 14-24) ventilations per minute. Conclusions: Highly trained professionals in an emergency department can achieve appropriate chest compression rates during CPR with a low hands-off ratio. Increased attention must be paid in all situations to the avoidance of hyperventilation.
引用
收藏
页码:2375 / 2380
页数:6
相关论文
共 29 条
[1]   CPR artifact removal from human ECG using optimal multichannel filtering [J].
Aase, SO ;
Eftestol, T ;
Husoy, JH ;
Sunde, K ;
Steen, PA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (11) :1440-1449
[2]   Compression depth estimation for CPR quality assessment using DSP on accelerometer signals [J].
Aase, SO ;
Myklebust, H .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (03) :263-268
[3]   Quality of cardiopulmonary resuscitation during in-hospital cardiac arrest [J].
Abella, BS ;
Alvarado, JP ;
Myklebust, H ;
Edelson, DP ;
Barry, A ;
O'Hearn, N ;
Vanden Hoek, TL ;
Becker, LB .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (03) :305-310
[4]   Chest compression rates during cardiopulmonary resuscitation are suboptimal - A prospective study during in-hospital cardiac arrest [J].
Abella, BS ;
Sandbo, N ;
Vassilatos, P ;
Alvarado, JP ;
O'Hearn, N ;
Wigder, HN ;
Hoffman, P ;
Tynus, K ;
Vanden Hoek, TL ;
Becker, LB .
CIRCULATION, 2005, 111 (04) :428-434
[5]  
*AM COLL EM PHYS, 1991, ANN EMERG MED, V20, P1389
[6]   Hyperventilation-induced hypotension during cardiopulmonary resuscitation [J].
Aufderheide, TP ;
Sigurdsson, G ;
Pirrallo, RG ;
Yannopoulos, D ;
McKnite, S ;
von Briesen, C ;
Sparks, CW ;
Conrad, CJ ;
Provo, TA ;
Lurie, KG .
CIRCULATION, 2004, 109 (16) :1960-1965
[7]   European Resuscitation Council Guidelines for Resuscitation 2005 - Section 9. Principles of training in resuscitation [J].
Baskett, PJF ;
Nolan, JP ;
Handley, A ;
Soar, J ;
Biarent, D ;
Richmond, S .
RESUSCITATION, 2005, 67 :S181-S189
[8]   CORONARY BLOOD-FLOW DURING CARDIOPULMONARY RESUSCITATION IN SWINE [J].
BELLAMY, RF ;
DEGUZMAN, LR ;
PEDERSEN, DC .
CIRCULATION, 1984, 69 (01) :174-180
[9]   Adverse hemodynamic effects of interrupting chest compressions for rescue breathing during cardiopulmonary resuscitation for ventricular fibrillation cardiac arrest [J].
Berg, RA ;
Sanders, AB ;
Kern, KB ;
Hilwig, RW ;
Heidenreich, JW ;
Porter, ME ;
Ewy, GA .
CIRCULATION, 2001, 104 (20) :2465-2470
[10]   Reducing no flow times during automated external defibrillation [J].
Eilevstjonn, J ;
Kramer-Johansen, J ;
Eftestol, T ;
Stavland, M ;
Myklebust, H ;
Steen, PA .
RESUSCITATION, 2005, 67 (01) :95-101